Contact Us:
sales@inosaki.com

MINI MCR-SL-IDS-I-I – 2905577 – Output Signal Conditioner – Phoenix Contact Signal Conditioners And Measuring Transducers

$ 227.24

Phoenix Contact develops terminal blocks, power supplies, relays, connectors, signal conditioners, controllers & PLCs, I/O systems, Industrial Ethernet, controller system cabling, PCB terminal blocks & connectors, and surge suppression.

Commercial Data

Item number 2905577
Packing unit 1 pc
Minimum order quantity 1 pc
Product key DK1132
Catalog page Page 100 (C-7-2015)
GTIN 4046356966290
Weight per piece (including packing) 87.7 g
Weight per piece (excluding packing) 87.7 g
Customs tariff number 85437090
Country of origin DE

Notes

Utilization restriction
EMC note EMC: class A product, see manufacturer’s declaration in the download area

Product Properties

Product type Repeater power supply
Product family MINI Analog
No. of channels 1
Insulation characteristics
Overvoltage category II
Pollution degree 2

Electrical Properties

Electrical isolation 3-way isolation
Limit frequency (3 dB) > 175 Hz
Protective circuit Transient protection
Signal transmission behavior In = Out
Step response (10-90%) < 2 ms
Maximum temperature coefficient < 0.01 %/K
Temperature coefficient, typical < 0.01 %/K
Maximum transmission error ≤ 0.1 % (of final value)
Electrical isolation Input/output/power supply
Rated insulation voltage 50 V AC/DC
Test voltage 1.5 kV AC (50 Hz, 60 s)
Insulation Basic insulation in accordance with IEC/EN 61010
Supply
Nominal supply voltage 24 V DC
Supply voltage range 19.2 V DC … 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715)
Power consumption < 600 mW (at 24 V DC)

Input Data

Signal
Number of inputs 1
Current input signal 0 mA … 20 mA
4 mA … 20 mA
Max. current input signal 20 mA
Input voltage limitation < 2 V (20 mA)

Output Data

Signal: Current
Number of outputs 1
Current output signal 0 mA … 20 mA
4 mA … 20 mA
Load/output load current output ≤ 800 Ω (at 20 mA)
Ripple < 20 mVrms

Connection Data

Connection method Screw connection
Stripping length 12 mm
Screw thread M3
Conductor cross section rigid 0.2 mm² … 2.5 mm²
Conductor cross section flexible 0.2 mm² … 2.5 mm²
Conductor cross section AWG 26 … 12

Interfaces

Data communication (bypass)
HART function Yes
Limit frequency (3 dB) 2.5 Hz

Dimension

Width 6.2 mm
Height 93.1 mm
Depth 101.2 mm

Material Specifications

Color green (RAL 6021)
Housing material PBT
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 – HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 – HL 2
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 – HL 2

Environmental and real-life conditions 

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -20 °C … 60 °C
Ambient temperature (storage/transport) -40 °C … 85 °C
Altitude ≤ 2000 m
Permissible humidity (operation) 5 % … 95 % (non-condensing)

Approvals

CE
Certificate CE-compliant
UKCA
Certificate UKCA-compliant
UL, USA/Canada
Identification UL 508 Listed
Class I, Div. 2, Groups A, B, C, D T4
Class I, Zone 2, Group IIC
Shipbuilding approval
Certificate DNV GL TAA000020N
Shipbuilding data
Temperature B
Humidity B
Vibration B
EMC A
Enclosure Required protection according to the Rules shall be provided upon installation on board

EMC Data

Electromagnetic compatibility Conformance with EMC directive
Noise immunity EN 61000-6-2
Note When being exposed to interference, there may be minimal deviations.
Noise emission
Standards/regulations EN 61000-6-4
Electrostatic discharge
Standards/regulations EN 61000-4-2
Electrostatic discharge
Comments Safety measures must be taken to prevent electrostatic discharge.
Electromagnetic HF field
Designation Electromagnetic RF field
Standards/regulations EN 61000-4-3
Typical deviation from the measuring range final value 3 %
Fast transients (burst)
Designation Fast transients (burst)
Standards/regulations EN 61000-4-4
Typical deviation from the measuring range final value 3 %
Surge current load (surge)
Standards/regulations EN 61000-4-5
Surge current load (surge)
Comments Criterion B
Conducted interference
Designation Conducted interferences
Standards/regulations EN 61000-4-6
Typical deviation from the measuring range final value 3 %

Standard And Regulations

Electrical isolation 3-way isolation

Mounting

Mounting type DIN rail mounting
Assembly note The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715.
Mounting position any

Additional information

Dimensions 10.12 × 0.62 × 9.31 cm