1. Normally Open Air-Purge Circuit Control
A machine circuit needs two air-purge lines whose specified normal valve state is open, with electrical commands changing the respective switching states. The dual normally open 3/2-way functions provide that arrangement in one 14 mm body. Mechanical spring reset returns the valve functions to their normal states, while the surrounding pneumatic circuit determines how each purge line is supplied and exhausted.
Problem Solved
Two normally open functions support purge circuits designed around an open normal state, consolidating their electrical switching and spring return in a single compact valve body.
2 × 3/2-way NO
Mechanical spring reset
14 mm
2. Normally Open Vacuum-Line Switching
A vacuum-handling circuit needs an electrically switched path with a normally open valve state. This model is explicitly suitable for vacuum, with a working-pressure limit of −0.9 bar and reversible flow direction. Its separate 4–8 bar pilot-pressure requirement defines the positive-pressure actuation conditions while the working circuit handles vacuum, supporting the chosen vacuum and venting arrangement.
Problem Solved
Documented vacuum suitability and a normally open switching function provide a defined vacuum-circuit valve state, while the pilot-pressure specification separates actuation requirements from sub-atmospheric working pressure.
Vacuum suitability
−0.9 bar
Reversible flow
3. MPA Valve-Station Flow Planning
A machine builder selects a dual normally open function for an MPA valve station and needs a flow figure matched to the actual platform. The manufacturer lists different nominal flows for MPA-S, MPA-L and MPA-C installations. Keeping those conditions with the rating supports station planning alongside the valve's 14 mm size, through-hole mounting and documented mounting-torque limit.
Problem Solved
Platform-specific flow information gives the builder a relevant rating for the chosen valve station, avoiding an unconditional flow assumption when integrating the dual normally open function.
MPA-S / MPA-L / MPA-C
Conditional flow ratings
0.65 Nm mounting limit