1. Reciprocating Fixture Cylinder Control
An assembly fixture moves a suitable double-acting cylinder between its working and return positions. The 5/2-way valve body supplies the two directional air-routing states, with mechanical spring reset and G1/4 connections. A separately selected F coil provides electrical actuation, while the 1000 l/min nominal flow and 2.2–8 bar working range characterize the pneumatic valve used in the cylinder circuit.
Problem Solved
The directional body supplies advance and return routing for the cylinder circuit, while mechanical reset and separate coil selection define its pneumatic and electrical actuation arrangement.
5/2-way
Mechanical spring
G1/4
2. Timed Product-Diverter Commands
A packaging machine commands a pneumatic diverter between two product routes and needs documented valve-response characteristics. This body specifies 9 ms switch-on and 29 ms switch-off times, with a 5/2 directional function and mechanical spring reset. The selected F coil supplies the electrical interface; the actual diverter travel time also depends on its actuator, tubing and mechanical load.
Problem Solved
Published component switching times support evaluation of the diverter command sequence, while the 5/2 function provides the two pneumatic routing states required by the actuator circuit.
9 ms on
29 ms off
1000 l/min
3. Grouped Valve Installation with Separate Coil Selection
A machine builder groups directional valves in a pneumatic control station and chooses the electrical coils to match the installation. This body supports manifold-rail or through-hole mounting, with a 30.5 mm width and 32 mm mounting pitch. Its separate F-coil arrangement keeps the electrical selection explicit, while detenting manual override provides the documented local actuation method during commissioning.
Problem Solved
Defined mounting and spacing organize the pneumatic control station, while separate F-coil selection matches the electrical actuation hardware without changing the identified valve-body configuration.
32 mm mounting pitch
Separate F coil
Manual override