Festo 8104668 Proportional Pressure Regulator, 0–10 bar, G1/8

Festo 8104668 Proportional Pressure Regulator, 0–10 bar, G1/8

Direct three-way regulator with 0–10 V or PWM setpoint, 0–10 V actual-value output, 1400 l/min nominal flow, five-pin M12 connection and IP65.

SKU: Festo-8104668 Category:
Festo Proportional Pressure Control Valves

Festo VPPI-5L-3-G18-0L10H-V1-S1 Proportional Pressure Regulator

BrandFesto
Model IdentifierVPPI-5L-3-G18-0L10H-V1-S1
Official Part Number8104668

Technical Overview

The Festo VPPI-5L-3-G18-0L10H-V1-S1 is a directly actuated three-way proportional pressure regulator with a 0–10 bar regulation range. A 0–10 V or PWM setpoint commands pressure, while a 0–10 V actual-value output provides feedback through the five-pin A-coded M12 interface. G1/8 supply, working and exhaust ports have 5 mm nominal supply/exhaust sizes, with 1400 l/min standard nominal supply flow and 750 l/min flow from port 2 to 3. The nominal supply is 24 V DC, and total accuracy is specified as 1.1% FS. The 365 g unit has IP65 protection, Class 4 cleanroom suitability and through-hole or DIN-rail mounting.

0–10 bar proportional pressure regulator with G1/8 ports, voltage/PWM setpoint, analogue actual-value output, five-pin M12 interface and IP65 protection.

Key Features

  • Three-way proportional pressure regulation from 0 to 10 bar
  • Direct poppet-valve design with mechanical spring return
  • Setpoint input via 0–10 V or pulse-width modulation
  • 0–10 V analogue actual-value output
  • 1400 l/min standard nominal supply flow; 750 l/min from port 2 to 3
  • G1/8 ports and 5 mm nominal supply/exhaust sizes
  • 24 V DC nominal supply with 21.6–27.6 V operating range
  • 1.1% FS total accuracy, 0.4% FS hysteresis and 0.4% FS reproducibility
  • Five-pin A-coded M12 connector and through-hole/DIN-rail mounting
  • 365 g product weight, IP65 protection and Class 4 cleanroom suitability

Command a 0–10 bar pressure setting by voltage or PWM and return an analogue actual-pressure signal through a single five-pin M12 interface.

Technical Specification Matrix

ParameterValue
Nominal size, supply5 mm
Nominal size, exhaust5 mm
Type of actuationElectrical
Sealing principleSoft
Total leakage5 l/h
Flow directionNon-reversible
Mounting positionAny
DesignPoppet valve with spring return
Short circuit current ratingFor all electrical connections
Max. cable length30 M
Setpoint value input0 - 10 V; Pulse-width modulation
Input resistance100 kOhm
Safety instructionsSafety position VPPI, normally closed
Reverse polarity protectionFor all electrical connections
Type of resetMechanical spring
Type of pilotingDirect
Valve function3-way proportional pressure regulator
Display typeLED
Operating pressure10 bar...12 bar
Pressure regulation range0 MPa...1 MPa; 0 bar...10 bar
Inlet pressure 10 bar...13 bar; 0 MPa...1.3 MPa
Burst pressure40 bar
Standard nominal flow rate (standardised to DIN 1343)1400 l/min
Standard nominal flow rate 2-3750 l/min
Operational voltage range DC21.6 V...27.6 V
Nominal current0.15 A
Max. current consumption525 mA
Max. electrical power consumption14.5 W
Nominal operating voltage DC24 V
Signal range analogue output0 - 10 V
Min. load resistance voltage output2000 Ohm
Accuracy analogue output in ± %FS1 %FS
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]; Inert gas
Note on operating and pilot mediumLubricated operation not possible
ApprovalRCM; c UL us - Listed (Oil)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Certificate issuing authorityUL E322346
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1
Suitable for use with foodSee supplementary material information
Media temperature0 °C...50 °C
Degree of protectionIP65
Pollution degree2
Ambient temperature0 °C...50 °C
Storage temperature-20 °C...70 °C
Climatic category3K3 according to EN 60721
Relative air humidity0 - 85%; Non-condensing
Nominal altitude of use< 3000 m NHN
Instructions on useThe product is suitable for industrial purposes only. Measures to; eliminate radio interference may be required in residential areas.
Sound power level62.5 dB(A)
Sound power level at a distance of 1 m51.9 dB(A)
Physical Weight (kg)0.365
Linearity0.9 %FS
Hysteresis0.4 %FS
Reproducibility0.4 %FS
Total accuracy1.1 %FS
Temperature cooefficient0.02 %/K
Electrical connection 1, functionActual value output; Setpoint input; Power supply
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores5
Electrical connection 1, tightening torque1.5 Nm
Type of mountingVia through-hole for M4 screw; via DIN rail
Pneumatic connection, port 1G1/8
Pneumatic connection, port 2G1/8
Pneumatic connection, port 3G1/8
Max. tightening torque for fitting8.5 Nm
Note on materialsRoHS compliant
Material housingReinforced PA
Material sealsHNBR; PTFE
Dimensions L x W x H (cm)9.53 x 4.22 x 9.43

Industrial Applications

1. Electronically Adjustable Fixture Pressure

A pneumatic fixture needs different working-pressure settings for different workpiece or process steps. The VPPI accepts a voltage or PWM setpoint over its 0–10 bar regulation range, allowing the control system to command the selected pressure rather than relying on a manual knob. G1/8 working connections and the 1400 l/min nominal supply rating characterize the regulator interface, while fixture force remains dependent on the actuator and mechanics.

Problem Solved

An electrical setpoint changes the regulated pressure as part of the machine sequence, supporting selectable pneumatic working conditions without requiring manual pressure adjustment for every step.

0–10 bar Voltage/PWM setpoint G1/8

2. Programmed Pressurization and Exhaust in a Test Fixture

A pneumatic test fixture needs commanded pressure changes and an exhaust path when the selected pressure is lowered. The three-way regulator provides supply and exhaust functions, with separately rated nominal supply flow of 1400 l/min and port 2-to-3 flow of 750 l/min. Its electrical setpoint defines the requested pressure, while actual pressure evolution depends on fixture volume, tubing and the test circuit.

Problem Solved

Three-way proportional regulation combines commanded pressurization and pressure reduction in one component, with separate supply and exhaust flow ratings for evaluating the test fixture circuit.

Three-way regulation 1400 l/min supply 750 l/min exhaust path

3. Actual-Pressure Feedback to a Machine Controller

A machine controller needs to observe the regulated pressure as well as issue the pressure command. The VPPI exposes a 0–10 V actual-value signal through the same five-pin M12 interface used for power and setpoint wiring. The analogue-output accuracy is specified separately as 1% FS, giving the controller interface its own documented measurement characteristic for recording or evaluating pressure behavior during operation.

Problem Solved

The actual-value output returns a pressure signal to the control system, enabling the machine workflow to observe the regulated condition alongside its commanded setpoint.

0–10 V actual value Five-pin M12 1% FS analogue-output accuracy