Festo 574354 Dual 3/2 Mixed NO/NC Valve, M5, External Pilot

Festo 574354 Dual 3/2 Mixed NO/NC Valve, M5, External Pilot

10 mm monostable valve with mechanical spring reset, 135 l/min nominal flow, 2–8 bar pilot supply, electrical sub-base connection and vacuum suitability.

SKU: Festo-574354 Category:
Festo Solenoid Valves

Festo VUVG-L10-T32H-MZT-M5-1P3 Mixed Normally Open/Closed Solenoid Valve

BrandFesto
Model IdentifierVUVG-L10-T32H-MZT-M5-1P3
Official Part Number574354

Technical Overview

The Festo VUVG-L10-T32H-MZT-M5-1P3 combines two monostable 3/2-way functions, one normally open and one normally closed, with mechanical spring reset. This 10 mm valve provides 135 l/min standard nominal flow through M5 working ports. External pilot air at 2–8 bar supports the −0.9 to 10 bar working range and documented vacuum suitability. The 24 V DC valve connects through an electrical sub-base, with 1.0 W high-current and 0.3 W low-current coil phases. Specified switching times are 8 ms on and 11 ms off. The 54 g assembly has Class 5 cleanroom suitability and IP40 protection, with IP65 specified when fitted with the plug socket.

10 mm mixed normally open/closed dual 3/2 valve with M5 ports, external pilot supply, spring reset and 135 l/min nominal flow.

Key Features

  • Two monostable 3/2-way functions: one normally open and one normally closed
  • 10 mm valve size with M5 working ports
  • 135 l/min standard nominal flow to DIN 1343
  • Mechanical spring reset
  • External pilot supply at 2–8 bar
  • −0.9 to 10 bar working range and documented vacuum suitability
  • 24 V DC electrical sub-base interface; 1.0 W high-current/0.3 W low-current coil phases
  • 8 ms on and 11 ms off switching times with 100% duty cycle
  • IP40 protection; IP65 with plug socket
  • 54 g product weight and Class 5 cleanroom suitability

Combine normally open and normally closed pneumatic branches in one 10 mm M5 valve with external pilot air and mechanical spring reset.

Technical Specification Matrix

ParameterValue
Valve function2x3/2-way, open/closed, monostable
Type of actuationElectrical
Valve size10 mm
Standard nominal flow rate (standardised to DIN 1343)135 l/min
pneumatic working portM5
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Type of resetMechanical spring
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; To EU Low Voltage Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions; To UK regulations for electrical equipment
Degree of protectionIP40; IP65; With plug socket
Nominal size1.8 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting; Concealed
Type of pilotingPiloted
Pilot air supplyExternal
lapOverlap
Pilot pressure0.2 MPa...0.8 MPa; 2 bar...8 bar
Suitability for vacuumYes
Switching time off11 ms
Switching time on8 ms
Duty cycle100%
Max. positive test pulse with 0 signal700 µs
Max. negative test pulse with 1 signal900 µs
Characteristic coil data24 V DC: 1.0 W; 24 V DC: low-current phase 0.3 W, high-current phase 1.0 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Restrictions for environmental and media temperature-5 - 50 °C; Without holding current reduction
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 5 according to ISO 14644-1
Media temperature-5 °C...60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...60 °C
Physical Weight (kg)0.054
Electrical connectionVia electrical sub-base
Type of mountingEither:; On manifold rail; With through-hole
Pilot air port 12/14M3
Pneumatic connection, port 1M5
Pneumatic connection, port 2M5
Pneumatic connection, port 4M5
Pneumatic connection, port 5M5
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingWrought aluminium alloy

Industrial Applications

1. Mixed Normal States for Purge and Air-Pulse Branches

A machine uses a purge branch designed around an open normal state and a separate air-pulse branch designed around a closed normal state. The dual 3/2 valve combines those two normal functions in one 10 mm body with mechanical spring reset. M5 interfaces and 135 l/min nominal flow characterize the selected pneumatic capacity, while electrical commands change the branch routing states through the sub-base interface.

Problem Solved

The mixed-function body groups the required open and closed normal-state branches, supporting their distinct pneumatic roles without selecting two identical normal functions by assumption.

Mixed NO/NC M5 ports 135 l/min

2. Single-Acting Fixture Circuits with Different Rest Routing

A fixture has two suitable single-acting pneumatic mechanisms whose normal valve routing requirements differ. One branch needs the normally open 3/2 function and the other the normally closed function, with mechanical spring reset returning each to its documented normal state. The valve's electrical sub-base connection and 24 V DC operation provide the command interface, while actual mechanism return behavior depends on the complete actuator circuits.

Problem Solved

Two different normal routing states are available within one valve body, giving the fixture an explicit pressure/vent arrangement for each single-acting circuit rather than forcing the same rest routing on both.

Two 3/2 functions Mechanical spring 24 V DC

3. Vacuum-Branch Switching with Separate Pilot Air

A vacuum-handling circuit requires a valve arrangement with mixed normal states and a positive actuation supply independent of the working vacuum. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar. External pilot air at 2–8 bar drives the valve functions, separating actuation requirements from the vacuum branch while retaining the documented normally open and normally closed routing options.

Problem Solved

External pilot air supplies positive actuation pressure for a vacuum working circuit, while the mixed normal functions provide the required branch-routing states in the selected pneumatic arrangement.

Vacuum suitability −0.9 bar working range 2–8 bar external pilot