Festo 196135 Solenoid Valve, 3/2 NC, QS-4, 24 V DC

Festo 196135 Solenoid Valve, 3/2 NC, QS-4, 24 V DC

Direct QS-4 poppet valve with 100 l/min nominal flow, 330 Hz maximum switching frequency, 1.7 ms on/2 ms off times and holding-current reduction.

SKU: Festo-196135 Category:
Festo Solenoid Valves

Festo MHE2-MS1H-3/2G-QS-4 Solenoid Valve

BrandFesto
Model IdentifierMHE2-MS1H-3/2G-QS-4
Official Part Number196135

Technical Overview

The Festo MHE2-MS1H-3/2G-QS-4 is a directly actuated 3/2-way normally closed solenoid valve with mechanical spring reset. Its pressure-relief poppet design provides 100 l/min standard nominal flow through QS-4 connections, with a maximum switching frequency of 330 Hz. Specified switching times are 1.7 ms on and 2 ms off. The 24 V DC coil uses 5.0 W in its high-current phase and 1.25 W in its low-current phase, with holding-current reduction and a two-pin plug connection. Normal operation spans −0.9 to 8 bar, while reversed operation is restricted to −0.9 to 1 bar. The 60 g valve has IP65 protection, a non-detenting manual override and a 10 mm construction width.

24 V DC direct 3/2-way normally closed QS-4 valve with 100 l/min nominal flow, 330 Hz maximum switching frequency and IP65 protection.

Key Features

  • 3/2-way normally closed function with mechanical spring reset
  • Direct pressure-relief poppet design
  • 100 l/min standard nominal flow to DIN 1343
  • 330 Hz maximum switching frequency
  • 1.7 ms switch-on and 2 ms switch-off times
  • 24 V DC coil: 5.0 W high-current and 1.25 W low-current phases
  • QS-4 ports and two-pin electrical plug connection
  • −0.9 to 8 bar operating range; reversed operation limited to −0.9 to 1 bar
  • IP65 protection, holding-current reduction and non-detenting manual override
  • 10 mm construction width, 14 mm mounting grid pitch and 60 g product weight

Switch QS-4 pneumatic circuits with a direct 3/2 normally closed valve offering 1.7 ms on and 2 ms off switching times.

Technical Specification Matrix

ParameterValue
Valve function3/2-way, single solenoid, closed
Type of actuationElectrical
Construction width10 mm
Standard nominal flow rate (standardised to DIN 1343)100 l/min
pneumatic working portQS-4
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar; -13.05 psi...116 psi
DesignPressure relief poppet valve
Type of resetMechanical spring
Degree of protectionIP65
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Nominal size2 mm
Mounting grid pitch14 mm
Mounting grid noteMinimum distance between the valves is 4 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideNon-detenting
Type of pilotingDirect
Flow directionReversible with restrictions
lapUnderlap
Reverse polarity protectionBipolar
Additional functionsSpark arresting; Holding current reduction; Protective circuit
Operating pressure, reversible-0.09 MPa...0.1 MPa; -0.9 bar...1 bar; -13.05 psi...14.5 psi
Max. switching frequency330 Hz
Switching time off2 ms
Switching time on1.7 ms
Tolerance switching time off+10%/-30%
Tolerance switching time on+10%/-30%
Switching time dispersion from 1 Hz0.2 ms
Duty cycle100%
Characteristic coil data24 V DC: low-current phase 1.25 W, high-current phase 5.0 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Restrictions for environmental and media temperatureAs a function of switching frequency (see graph)
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 6 according to ISO 14644-1
Media temperature-5 °C...60 °C
Ambient temperature-5 °C...60 °C
Physical Weight (kg)0.06
Electrical connection2-pin; Plug
Type of mountingWith through-hole
Pneumatic connection, port 1QS-4
Pneumatic connection, port 2QS-4
Pneumatic connection, port 3QS-4
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingDie-cast zinc, coated
Material screwsGalvanised steel

Industrial Applications

1. Timed Air Pulses at a Process Nozzle

A production station needs electrically timed air pulses at a small pneumatic nozzle. The valve's 3/2 normally closed function and mechanical spring reset provide electrically commanded flow switching, with 1.7 ms on and 2 ms off component times. Its 100 l/min nominal flow and QS-4 ports characterize the selected pneumatic capacity, while the 330 Hz maximum switching frequency defines a component limit rather than a guaranteed nozzle pulse rate. The permitted temperature also depends on switching frequency.

Problem Solved

The direct valve provides a documented electrical-to-pneumatic switching element for timed air delivery, with explicit switching-time and flow data for evaluating the pulse circuit.

1.7 ms on / 2 ms off 330 Hz maximum 100 l/min

2. Control of a Single-Acting Fixture Actuator

A fixture uses a single-acting pneumatic mechanism that needs an electrical command to pressurize its working line and a valve return state when the coil is de-energized. The 3/2 normally closed design supplies the corresponding directional function, with mechanical spring reset. A 24 V DC two-pin connection interfaces with the machine wiring, and the 100% duty rating permits continuous coil energization within the specified conditions.

Problem Solved

The three-port directional function and spring reset provide the valve states needed for an electrically commanded single-acting circuit, with a documented continuous-duty coil rating.

3/2 normally closed Mechanical spring 24 V DC

3. Direct Switching of a Vacuum Branch

A vacuum-handling branch needs an electrically actuated valve without relying on a separate pilot-air pressure differential. The MHE2 uses direct actuation and has a documented negative-pressure operating range down to −0.9 bar. Flow reversal is permitted only with restrictions and a separate −0.9 to 1 bar range, so the vacuum circuit arrangement must follow that documented distinction rather than treating the valve as unrestricted in either direction.

Problem Solved

Direct actuation supplies electrical switching for the negative-pressure circuit, while the explicit normal and reversed pressure ratings define the supported pneumatic arrangement of the branch.

Direct actuation −0.9 bar capability Restricted reversal