Festo 8001460 Piloted Check Valve, G1/8, QS-6, Manual Exhaust

Festo 8001460 Piloted Check Valve, G1/8, QS-6, Manual Exhaust

Pneumatic non-return valve with non-detenting manual exhaust, QS-6 working and pilot ports, 0.2–10 bar operating range and 27.3 g product weight.

SKU: Festo-8001460 Category:
Festo Check Valves

Festo VBNF-LBA-G18-Q6-F1A Piloted Check Valve

BrandFesto
Model IdentifierVBNF-LBA-G18-Q6-F1A
Official Part Number8001460

Technical Overview

The Festo VBNF-LBA-G18-Q6-F1A combines a pneumatically piloted non-return function with non-detenting manual exhaust. Its screw-in G1/8 connection, QS-6 working connection and QS-6 pilot port support mounting at a pneumatic drive. Working pressure spans 0.2–10 bar, while pilot pressure is 2–10 bar. The manufacturer specifies 260 l/min nominal flow from port 1 to 2 under 6-to-5 bar conditions, distinct from 500 l/min under 6-to-0 conditions. The 27.3 g PBT-housed valve can be oriented through 360° during installation, with continuous swivelling prohibited. F1A material characteristics address reduced Cu/Zn/Ni values for battery production, and ambient/media limits are −10 to 60 °C.

G1/8 piloted check valve with QS-6 working and pilot connections, manual exhaust and F1A material characteristics.

Key Features

  • Pneumatically piloted non-return function
  • Integrated non-detenting manual exhaust
  • QS-6 port 1, G1/8 port 2 and QS-6 pilot port 21
  • 0.2–10 bar operating range; 2–10 bar pilot pressure
  • 260 l/min nominal flow 1→2 at 6-to-5 bar conditions
  • 500 l/min flow 1→2 at 6-to-0 bar conditions
  • 6 ms switch-on and 9 ms switch-off times
  • 360° installation orientation; continuous swivelling prohibited
  • 27.3 g product weight, PBT housing and NBR seals
  • F1A reduced Cu/Zn/Ni material characteristics; −10 to 60 °C ambient/media range

Combine pilot-controlled non-return action and local manual exhaust at a G1/8 drive connection with QS-6 tubing interfaces.

Technical Specification Matrix

ParameterValue
Valve functionPiloted non-return function
Selection of additional functionsManual exhausting
Pneumatic connection, port 1QS-6
Pneumatic connection, port 2G1/8
Pilot air port 21QS-6
Type of mountingScrew-in
Operating pressure0.02 MPa...1 MPa; 0.2 bar...10 bar
Pilot pressure0.2 MPa...1 MPa; 2 bar...10 bar; 29 psi...145 psi
Ambient temperature-10 °C...60 °C
Material housingPBT
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Mounting positionAny
Type act., cont. n.-r. func.Pneumatic
Manual exhaust functionNon-detenting
Rotatability360°/no continuous swivelling permissible
Operating pressure complete temperature range0.02 MPa...1 MPa; 0.2 bar...10 bar; 2.9 psi...145 psi
Standard flow rate 1->2 (6-0)500 l/min
Standard nominal flow rate 1->2 (6-5)260 l/min
Switching time off9 ms
Switching time on6 ms
Explosion protectionZone 2 (ATEX); Zone 22 (ATEX)
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Media temperature-10 °C...60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Nominal torque6 Nm
Tolerance for nominal tightening torque±20%
Physical Weight (kg)0.0273
Material coveringES-BE
Note on materialsRoHS compliant
Material coverPBT
Material sealsNBR
Material hollow boltWrought aluminium alloy
Material release ringPOM

Industrial Applications

1. Brief Intermediate Pause of a Pneumatic Drive

A pneumatic transfer mechanism needs a brief intermediate pause during its sequence. Festo describes using the piloted non-return function to block drive exhaust when the control signal is absent, briefly stopping the drive. This G1/8 version provides QS-6 working and pilot connections, with separate 0.2–10 bar working and 2–10 bar pilot-pressure ranges for implementing that pneumatic control arrangement.

Problem Solved

Blocking the drive exhaust through the non-return function provides a brief pneumatic pause, while the separate pilot input controls when the exhaust path can be released.

Piloted non-return QS-6 pilot G1/8 drive connection

2. Pilot-Commanded Exhaust during Actuator Return

A cylinder circuit must allow air out of a checked chamber when the next motion command calls for return travel. The pneumatic pilot input releases the non-return function so the drive exhaust can escape. A dedicated QS-6 pilot connection carries that control signal, while the exact valve's documented flow and switching-time ratings characterize the component used in the return circuit.

Problem Solved

Pilot-controlled release provides an exhaust path when the sequence requires return movement, allowing a chamber with non-return control to participate in commanded actuator travel.

Pneumatic pilot release QS-6 pilot port 6 ms on / 9 ms off

3. Local Exhausting of a Pneumatic Drive

During a setup intervention, a technician needs a local way to exhaust the connected pneumatic drive rather than relying solely on a remote pilot command. The integrated manual exhaust function supplies that action directly at the valve. Its non-detenting mechanism requires deliberate actuation, while the screw-in G1/8 mounting and orientable housing support locating the manual control at the drive connection.

Problem Solved

Integrated manual exhausting gives the technician a local means to release air from the connected drive, adding an accessible intervention function to the piloted check assembly.

Manual exhaust Non-detenting Screw-in G1/8