1. Position Confirmation at a Compact Sensor Mount
A compact machine mechanism needs a non-contact signal when a suitable metal target reaches a defined position. The M5×0.5 sensor mounts through a bracket using lock nuts and permits flush installation. Its 0.8 mm rated distance and 0.01 mm repetition accuracy under constant conditions characterize the switching geometry, while the 1.5 Nm tightening torque defines the documented mounting requirement.
Problem Solved
Threaded mounting locates the inductive switching point near the mechanism, providing a position signal through the normally closed PNP output without requiring physical contact with the target.
M5×0.5 lock-nut mounting
0.8 mm rated distance
PNP NC
2. Pulse Counting from Separated Metal Index Features
A machine controller counts passing metal index features to observe repeated mechanical cycles. Each suitable target entering and leaving the inductive field changes the PNP normally closed output, and the 5000 Hz maximum switching frequency defines the component response limit. The three-pin M8 A-coded plug and 10–30 V DC supply provide the electrical interface, while actual target spacing and circuit timing determine usable pulse separation.
Problem Solved
Inductive switching converts separated metal index passages into electrical pulses, supplying the controller with events for cycle counting through a documented industrial sensor interface.
5000 Hz maximum
PNP normally closed
Three-pin M8 plug
3. Missing Metal Insert Detection in an Assembly Nest
An assembly nest needs to detect whether a suitable metal insert is present before the next process step. The compact flush M5×0.5 body places an inductive sensing point close to the target, with a 0.8 mm rated distance. Its PNP normally closed output supplies the discrete sensing result, and the yellow LED provides local indication of the switching state.
Problem Solved
The switching output supplies a presence result for the metal insert, allowing the assembly sequence to distinguish a detected target from an empty sensing location.
Metal insert presence
0.8 mm rated distance
PNP normally closed