1. Local Working-Pressure Adjustment at an Actuator
An assembly fixture needs a local pressure setting for one pneumatic working line. The diaphragm regulator places a 0.5–7 bar adjustment between an M5 inlet and M5 outlet, with a gauge showing the regulated condition. The detented knob supports setting the pressure at the point of use rather than making the whole machine supply use that same setting.
Problem Solved
A local regulator gives the selected working line its own pressure adjustment and visible gauge reading, supporting a different pneumatic setting from the surrounding machine supply.
0.5–7 bar
M5 ports
Integrated gauge
2. Reducing Regulated Pressure During Product Changeover
A machine operator changes a fixture to a lower regulated-pressure setting for the next product. The regulator includes secondary exhausting, providing a relief function on the regulated side as the setpoint is adjusted downward. Its pressure gauge gives a local indication of the resulting pressure, while the rotary knob detent forms part of the manual adjustment interface.
Problem Solved
Secondary exhausting gives the downstream side a pressure-relief path during adjustment, while the gauge shows the regulated condition instead of leaving the operator to infer it from knob position.
Secondary exhausting
Pressure gauge
Detented knob
3. Regulated Line with a Required Return-Flow Path
A pneumatic circuit needs forward pressure regulation while also permitting return flow through the same local regulator arrangement. This model explicitly includes a return-flow function alongside constant output pressure and secondary exhausting. Its M5 inlet and outlet interfaces make the connection arrangement clear, and the 170 l/min standard nominal flow rating provides a documented regulator characteristic for circuit selection.
Problem Solved
The integrated return-flow function accommodates reverse flow in a line that also needs forward pressure regulation, combining those pneumatic functions in one compact regulator component.
Return-flow function
170 l/min nominal
Inline mounting