Festo 153468 Manual Shut-off Valve, 2/2 Bistable, QS-8

Festo 153468 Manual Shut-off Valve, 2/2 Bistable, QS-8

Manual QS-8 shut-off valve with 415.8 l/min nominal flow, reversible operation, −0.95 to 10 bar range, reinforced PBT housing and 26 g weight.

SKU: Festo-153468 Category:
Festo Mechanical And Hand Operated Valves

Festo HE-2-QS-8 Manual Shut-off Valve

BrandFesto
Model IdentifierHE-2-QS-8
Official Part Number153468

Technical Overview

The Festo HE-2-QS-8 is a manually actuated 2/2-way bistable shut-off valve with QS-8 connections at both ports. Its directly operated, soft-sealed piston gate mechanism provides maintained open and closed states, with reversible flow and 415.8 l/min standard nominal flow to DIN 1343. The 3.5 mm nominal size and −0.95 to 10 bar operating range characterize this exact version. Inline installation or direct through-hole mounting supports local access in any position. The 26 g reinforced-PBT assembly uses NBR seals, with 0–60 °C ambient and media limits and documented Class 4 cleanroom suitability.

Manual 2/2-way bistable QS-8 shut-off valve with 415.8 l/min nominal flow, reversible flow and 26 g product weight.

Key Features

  • 2/2-way bistable shut-off function
  • Direct manual actuation with maintained open/closed states
  • QS-8 connections at both ports
  • 415.8 l/min standard nominal flow to DIN 1343
  • 3.5 mm nominal size and reversible flow
  • −0.95 to 10 bar operating-pressure range
  • Inline or direct through-hole mounting in any position
  • Soft-sealed piston gate design with NBR seals
  • 26 g reinforced-PBT assembly with CRC 2 corrosion resistance
  • Class 4 cleanroom suitability and 0–60 °C ambient/media range

Open or close an 8 mm pneumatic line locally with a maintained manual command in a 26 g valve.

Technical Specification Matrix

ParameterValue
Valve function2/2-way, bistable
Pneumatic connection, port 1QS-8
Pneumatic connection, port 2QS-8
Type of actuationManual
Type of mountingEither:; Direct mounting via through-hole; Inline installation
Standard nominal flow rate (standardised to DIN 1343)415.8 l/min
Nominal size3.5 mm
Operating pressure-0.095 MPa...1 MPa; -0.95 bar...10 bar
Ambient temperature0 °C...60 °C
Material housingReinforced PBT
Operating mediumCompressed air to ISO 8573-1:2010 [7:-:-]
Sealing principleSoft
Mounting positionAny
DesignPiston gate valve
Type of pilotingDirect
Flow directionReversible
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1
Media temperature0 °C...60 °C
Physical Weight (kg)0.026
Note on materialsRoHS compliant
Material sealsNBR

Industrial Applications

1. Local Air Enable at a Workstation

An operator needs to open or close the air feed to a pneumatic workstation at the point of use. The directly operated 2/2 valve provides maintained open and closed states without a pilot-air or electrical command. QS-8 connections link it to 8 mm tubing, while inline or through-hole mounting places that manual control near the workstation.

Problem Solved

A maintained manual state supplies a local air-feed command, allowing the operator to control the selected workstation branch through a simple two-port pneumatic connection.

Manual actuation 2/2 bistable QS-8 ports

2. Manual Disconnection of a Test-volume Feed

A pneumatic test fixture first charges a volume, then needs the operator to close its feed path for the next process step. The valve's two-port shut-off function interrupts that path without selecting an exhaust connection. Its bistable mechanism maintains the chosen position, and the documented 415.8 l/min nominal flow characterizes the component during the open charging condition.

Problem Solved

Two-port shut-off interrupts the charging path while avoiding an intentional exhaust route through the valve, providing a maintained connection state for the fixture's controlled sequence.

Two-port shut-off Maintained state 415.8 l/min nominal

3. Manual Switching of a Vacuum Branch

A vacuum fixture requires a local open/close control in its tubing connection. This valve's −0.95 to 10 bar operating range includes negative pressure, and reversible flow permits either direction through the open passage. Direct manual actuation changes the connection state independently of pilot pressure, while the NBR seals and reinforced-PBT housing form the documented valve construction.

Problem Solved

Direct manual switching provides a local control point in the vacuum branch, with documented negative-pressure operation and reversible flow defining the supported connection conditions.

−0.95 bar range limit Reversible flow Direct operation