Festo 8022035 Double 5/2 Solenoid Valve, 24 V DC, 860 l/min

Festo 8022035 Double 5/2 Solenoid Valve, 24 V DC, 860 l/min

20 mm double-solenoid valve with reversible flow, vacuum suitability, −0.9 to 10 bar working pressure, 3–8 bar pilot pressure and IP65 protection.

SKU: Festo-8022035 Category:
Festo Solenoid Valves

Festo VMPA2-M1BH-J-PI Double-Solenoid Valve

BrandFesto
Model IdentifierVMPA2-M1BH-J-PI
Official Part Number8022035

Technical Overview

The Festo VMPA2-M1BH-J-PI is a 20 mm, double-solenoid 5/2-way valve with 24 V DC actuation and 860 l/min standard nominal flow. Its working-pressure range extends from −0.9 to 10 bar, with documented vacuum suitability and reversible flow; the pilot-pressure requirement is separately specified at 3–8 bar. The soft-sealed piston gate design switches on in 9 ms and reverses in 22 ms. Signal indication and detenting or non-detenting manual override support commissioning, while the 100 g die-cast aluminium body, NBR seals and IP65 protection suit installation from −5 to 50 °C.

20 mm double-solenoid 5/2 valve with 24 V DC actuation, 860 l/min nominal flow, reversible routing, vacuum suitability and IP65 protection.

Key Features

  • Double-solenoid 5/2-way electrical switching function
  • 20 mm valve size and soft-sealed piston gate design
  • 860 l/min standard nominal flow, also specified with QS-10
  • 24 V DC operation with ±25% permissible voltage variation
  • −0.9 to 10 bar working pressure and separate 3–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • 9 ms switch-on and 22 ms reversal times
  • Signal indication and detenting/non-detenting manual override
  • IP65 protection with through-hole mounting; 0.65 Nm maximum mounting torque
  • 100 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient range

Switch a reversible 5/2 pneumatic circuit with 860 l/min nominal flow and documented vacuum suitability in a 20 mm valve.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, double solenoid
Type of actuationElectrical
Valve size20 mm
Standard nominal flow rate (standardised to DIN 1343)860 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumYes
Standard nominal flow rate with QS-10860 l/min
Switching time on9 ms
Switching time reversal22 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal900 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.65 Nm
Physical Weight (kg)0.1
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Double-Acting Cylinder Direction Control

A transfer fixture needs electrical commands to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's double-solenoid 5/2 function supplies the required two routing states. Its 860 l/min standard nominal flow and 22 ms reversal specification provide defined component data for coordinating directional switching with the machine's pneumatic sequence.

Problem Solved

The 5/2 routing function alternates the cylinder working connections between supply and exhaust, letting the controller command travel direction through the two electrical solenoids.

5/2 double solenoid 860 l/min nominal 22 ms reversal

2. Vacuum-Circuit Path Switching

A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.

Problem Solved

Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.

Vacuum suitability −0.9 bar 3–8 bar pilot

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 20 mm valve uses through-hole mounting with a specified 0.65 Nm maximum valve-mounting torque for installation.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override Signal indication 20 mm