1. Double-Acting Cylinder Direction Control
A transfer fixture needs electrical control to alternate pressure and exhaust between the two chambers of a double-acting cylinder. The valve's single-solenoid 5/2 function supplies the required routing states, with pneumatic spring reset. Its 870 l/min standard nominal flow and 15 ms switch-on/28 ms switch-off times provide defined component data for coordinating directional switching with the machine sequence.
Problem Solved
The 5/2 routing function alternates the cylinder working connections between supply and exhaust, combining an electrical switching command and pneumatic spring reset for directional control.
5/2 single solenoid
Pneumatic spring reset
870 l/min nominal
2. Vacuum-Circuit Path Switching
A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.
Problem Solved
Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.
Vacuum suitability
−0.9 bar
3–8 bar pilot
3. Valve-Station Commissioning
During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 20 mm valve uses through-hole mounting with a specified 0.65 Nm maximum valve-mounting torque for installation.
Problem Solved
Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.
Manual override
Signal indication
20 mm