1. Machine Mechanism Position Confirmation
A mechanism needs an electrical signal when its metal target reaches a defined position beside a fixed sensor. Flush mounting and female-thread attachment secure the rectangular device close to the target path. The 1.5 mm rated distance, 1.2 mm assured distance and 0.07 mm repetition accuracy define the sensing characteristics, with a PNP normally closed signal for the controller.
Problem Solved
Non-contact inductive switching reports the target position without a mechanical contact, while the defined operating distances and repetition accuracy characterize the available position signal.
PNP NC
1.2 mm assured
0.07 mm repetition
2. Counting Separated Metal Index Features
A production machine counts separated metal features passing the sensor to observe repeated mechanical cycles. Each suitable feature entering and leaving the inductive field changes the normally closed output state. The 1500 Hz maximum DC switching frequency characterises the sensor response limit, and the three-pin M8 connection provides the interface for the controller's counting input.
Problem Solved
Inductive target passages become discrete electrical events for cycle counting, with a published DC switching limit providing a defined component response for the machine's pulse timing.
1500 Hz DC maximum
Metal index pulses
Three-pin M8
3. Metal Insert Presence in an Assembly Nest
An assembly nest needs to establish whether a metal insert occupies its sensing position before the next operation. The inductive sensor detects the nearby metal target and changes its PNP normally closed signal. Published reduction factors are 1.0 for steel St 37, 0.8 for stainless steel St 18/8 and 0.45 for aluminium, defining useful material distinctions for the sensing gap.
Problem Solved
A discrete presence signal lets the controller distinguish the sensed insert condition from an empty location, while material-specific reduction factors characterize the target-dependent sensing distance.
Metal insert presence
Material reduction factors
PNP normally closed