Festo 575586 Normally Open 3/2-Way Valve, G3/8, 24 V DC

Festo 575586 Normally Open 3/2-Way Valve, G3/8, 24 V DC

Externally piloted 31 mm valve with mechanical spring reset, reversible flow, 2300 l/min nominal flow, Type C connection and IP65 with plug socket.

SKU: Festo-575586 Category:
Festo Solenoid Valves

Festo VUVS-L30-M32U-MZD-G38-F8-1C1 Normally Open Solenoid Valve

BrandFesto
Model IdentifierVUVS-L30-M32U-MZD-G38-F8-1C1
Official Part Number575586

Technical Overview

The Festo VUVS-L30-M32U-MZD-G38-F8-1C1 is a normally open, single-solenoid 3/2-way valve with mechanical spring reset. Its 31 mm piston-gate body provides 2300 l/min standard nominal flow through G3/8 working ports, with a 9.4 mm nominal passage and reversible flow direction. External pilot air at 2.5–10 bar operates separately from the −0.9 to 10 bar working circuit through G1/8 pilot port 12. The 24 V DC, 3.3 W coil uses a Type C connection to EN 175301-803, with 15 ms switch-on and 57 ms switch-off times. The 405 g valve supports manual override, manifold mounting and IP65 with a plug socket.

31 mm normally open 3/2-way valve with external pilot supply, G3/8 ports, mechanical spring reset, 24 V DC coil and 2300 l/min nominal flow.

Key Features

  • Normally open 3/2-way single-solenoid function
  • 31 mm valve size, piston-gate design and 9.4 mm nominal passage
  • 2300 l/min standard nominal flow to DIN 1343
  • G3/8 working ports with reversible flow direction
  • −0.9 to 10 bar working-pressure range
  • External pilot supply at 2.5–10 bar through G1/8 pilot port 12
  • 24 V DC, 3.3 W coil data and 100% duty cycle
  • Type C electrical connection to EN 175301-803
  • 15 ms switch-on and 57 ms switch-off times; mechanical spring reset
  • 405 g product weight, manual override and IP65 with plug socket

Provide normally open G3/8 supply-and-exhaust switching at 2300 l/min nominal flow while a separate pilot-air supply operates the valve.

Technical Specification Matrix

ParameterValue
Valve function3/2-way, single solenoid, open
Type of actuationElectrical
Valve size31 mm
Standard nominal flow rate (standardised to DIN 1343)2300 l/min
pneumatic working portG3/8
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; With plug socket; To IEC 60529
Nominal size9.4 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Pilot air supplyExternal
Flow directionReversible
lapOverlap
Pilot pressure0.25 MPa...1 MPa; 2.5 bar...10 bar
b value0.3
C value9.2 l/sbar
Switching time off57 ms
Switching time on15 ms
Duty cycle100%
Max. positive test pulse with 0 signal2000 µs
Max. negative test pulse with 1 signal3600 µs
Characteristic coil data24 V DC: 3.3 W
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 6 according to ISO 14644-1
Media temperature-10 °C...60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-10 °C...60 °C
Physical Weight (kg)0.405
Electrical connectionType C; To EN 175301-803
Type of mountingEither:; On manifold rail; With through-hole
Breather connectionNot ducted
Pilot exhaust port 82M5
Pilot air port 12G1/8
Pneumatic connection, port 1G3/8
Pneumatic connection, port 2G3/8
Pneumatic connection, port 3G3/8
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingDie-cast aluminium; painted
Material piston slideWrought aluminium alloy
Material screwsNickel-plated steel

Industrial Applications

1. Normally Supplied Air Branch with Commanded Interruption

A machine process uses an air branch that is supplied in the valve’s unactuated state and interrupted under electrical command. The normally open 3/2-way function provides supply-and-exhaust switching for that arrangement. Its G3/8 working ports and 2300 l/min nominal flow characterize the branch connection, while mechanical spring reset returns the valve to its normal switching state.

Problem Solved

Normally open routing supports a process branch that requires air supply in the unactuated valve state, with electrical actuation changing the working connection during the sequence.

3/2-way normally open 2300 l/min nominal Mechanical spring reset

2. Separate-Pilot Control of a Low-Pressure Fixture Branch

A fixture branch uses a working pressure lower than the valve’s required actuation pressure. The external pilot connection accepts 2.5–10 bar independently of the specified working circuit, allowing the positive pilot supply to operate the valve. The normally open 3/2-way function defines how the fixture branch is supplied and exhausted, with a 24 V DC electrical command.

Problem Solved

External pilot air separates the valve’s actuation requirement from the fixture’s working-pressure setting, supporting normally open switching when the process branch uses a different pressure condition.

External pilot 2.5–10 bar pilot 24 V DC command

3. Manual Commissioning of a Pneumatic Station

During commissioning, a station needs to exercise its pneumatic branch while checking the installed control sequence. Detenting and non-detenting manual override allow local valve actuation, and mechanical spring reset defines the normally open return state. Manifold-rail or through-hole mounting positions the valve in the control assembly, while the Type C connector provides its electrical interface.

Problem Solved

Local manual actuation lets the pneumatic branch be exercised at the valve during commissioning, supporting observation of the connected mechanism alongside the electrical control checks.

Manual override Normally open return Type C connection