Festo 574011 Monitored Control Block, 3/2 NC, G1/4, PNP

Festo 574011 Monitored Control Block, 3/2 NC, G1/4, PNP

Internally piloted 24 V DC control block with G1/4 ports, spring reset, PNP normal-position sensing, 1050 l/min nominal flow and IP65/NEMA 4 protection.

Festo Application-Specific Directional Control Valves

Festo VOFA-L26-T32C-M-G14-1C1-APP Monitored Control Block

BrandFesto
Model IdentifierVOFA-L26-T32C-M-G14-1C1-APP
Official Part Number574011

Technical Overview

The Festo VOFA-L26-T32C-M-G14-1C1-APP is an internally piloted, normally closed 3/2-way control block with mechanical spring reset and PNP inductive normal-position sensing. It uses G1/4 pneumatic ports, 24 V DC Type C valve connections and three-pin M8 sensor plugs. Standard nominal flow is 1050 l/min; the exhaust figure at 6→0 bar is separately specified as 2650 l/min. Festo lists exhausting and prevention of unexpected start-up among its functions, with performance up to category 4, PL e dependent on the prescribed two-channel control and diagnostic implementation. The 1134 g block operates at 3–10 bar and −5 to +50 °C.

G1/4 normally closed 3/2-way control block with 24 V DC actuation, mechanical spring reset, PNP position sensing and 1050 l/min nominal flow.

Key Features

  • Normally closed 3/2-way function with linked valve channels
  • Mechanical spring reset and internal pilot-air supply
  • G1/4 pneumatic connections at ports 1, 2 and 3
  • 1050 l/min standard nominal flow to DIN 1343
  • 2650 l/min exhaust flow at 6→0 bar; 1050 l/min specified in the error case
  • 24 V DC, 1.8 W coil data and Type C connection to EN 175301-803
  • PNP inductive normal-position sensing through a three-pin M8×1 plug
  • Sensor 10–30 V DC range, 200 mA maximum output and N/C contact function
  • 3–10 bar operating pressure; −5 to +50 °C ambient/media range
  • IP65/NEMA 4, 65 mm construction width and 1134 g product weight

Combine a normally closed exhaust-control function with PNP valve-position feedback in a G1/4 block for monitored pneumatic control.

Technical Specification Matrix

ParameterValue
Valve function3/2-way, normally closed, monostable
Type of actuationElectrical
Construction width65 mm
Standard nominal flow rate (standardised to DIN 1343)1050 l/min
pneumatic working portG1/4
Operating voltage24 V DC
Operating pressure0.3 MPa...1 MPa; 3 bar...10 bar; 43.5 psi...145 psi
DesignPiston gate valve
Type of resetMechanical spring
Degree of protectionIP65; NEMA 4
Approvalc UL us - Recognised (Oil)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive; To EC Machinery Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK regulations for machines
Certificate issuing authorityUL MH19482
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Conforms to standardEN 60947-5-2
Manual overrideNone
Type of pilotingPiloted
Pilot air supplyInternal
Flow directionNon-reversible
Measuring principleInductive
lapOverlap
Reverse polarity protection sensorFor all electrical connections
Safety functionExhaust; Protection against manipulation, prevention of unexpected start-up
Performance Level (PL)Exhausting/up to category 4, performance level e; Protection against manipulation, prevention of unexpected start-up/up; to category 4, Performance Level e
Note on forced dynamizationSwitching frequency min. 1/week
Signal status displayWith accessories
Switching position sensingNormal position with sensor
Switching status display sensorLED
Pilot pressure0.3 MPa...1 MPa; 3 bar...10 bar
Suitability for vacuumNo
Exhaust flow at 6→0 bar2650 l/min
Exhaust flow at 6→0 bar in error case1050 l/min
Switching time off54 ms
Switching time on24 ms
Valve - sensor switching time on58 ms
Valve - sensor switching time off11 ms
Duty cycle100%
Max. positive test pulse with 0 signal1000 µs
Max. negative test pulse with 1 signal800 µs
Switching outputPNP
Characteristic coil data24 V DC: 1.8 W
Permissible voltage fluctuations-15% / +10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Max. magnetic interference field60 mT
Media temperature-5 °C...50 °C
Sound pressure level85 dB(A)
Protection against direct and indirect contactPELV; Protection class to EN60950/IEC 950
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...50 °C
Nominal altitude of use1000 m in accordance with VDE 0580
Physical Weight (kg)1.134
Operating voltage range, DC sensor10 V...30 V
Short-circuit strength sensorPulsed
Idle current sensor10 mA
Max. output current sensor200 mA
Max. switching frequency sensor5000 Hz
Residual ripple sensor±10%
Voltage drop sensor2 V
Electrical connectionType C; To EN 175301-803; Without PE conductor
Sensor connectionPlug; 3-pin; M8x1
Type of mountingWith through-hole
Pneumatic connection, port 1G1/4
Pneumatic connection, port 2G1/4
Pneumatic connection, port 3G1/4
Note on materialsRoHS compliant
Material sealsFluoro rubber; HNBR; NBR
Material housingDie-cast aluminium; PA
Material screwsGalvanised steel
Switching element functionN/C contact

Industrial Applications

1. Monitored Exhaust of a Pneumatic Machine Zone

A machine zone needs a normally closed pneumatic supply and exhaust function as part of its monitored control architecture. The T32C block links the valve channels to provide the documented 3/2 function, with mechanical spring reset and PNP normal-position sensing. Festo specifies 2650 l/min exhaust flow at 6→0 bar and 1050 l/min for the stated error case, allowing those component conditions to be evaluated separately.

Problem Solved

The block combines the documented exhaust routing with valve-position feedback, providing both a pneumatic action and an observable component state for the machine control architecture.

3/2 normally closed PNP position sensing 2650 l/min exhaust

2. Two-Channel Restart-Prevention Circuit

An industrial automation system needs to prevent unintended pneumatic start-up after a stop condition. Festo identifies prevention of unexpected start-up as a function of this linked control block. Its normally closed valve function and mechanical spring reset support that architecture; reaching the stated category 4, PL e capability requires independent actuation channels and the manufacturer-prescribed diagnostic implementation in the complete system.

Problem Solved

The linked valve arrangement provides the pneumatic control element for a restart-prevention architecture, with spring-return behavior and documented position sensing available to the supervising control system.

Restart-prevention function Mechanical spring reset Two-channel control

3. Valve-State Diagnostics in an Automated Station

An automated station needs to compare its valve commands with the observed spool state. The APP variant uses PNP inductive normal-position sensors with three-pin M8 plugs and a 10–30 V DC sensor range. Festo describes evaluating actuation and feedback together in software to detect whether the spools have reached or left their normal positions, supporting the station diagnostic sequence.

Problem Solved

Normal-position feedback makes the valve state observable to diagnostic logic, allowing the control system to compare commanded switching with the measured return or departure from normal position.

PNP feedback M8 sensor plugs 10–30 V DC sensors