Festo 568655 Dual Normally Open 3/2 Valve, 20 mm, 24 V DC

Festo 568655 Dual Normally Open 3/2 Valve, 20 mm, 24 V DC

20 mm dual normally open valve with mechanical spring reset, vacuum suitability, MPA-S/QS-8 550 or MPA-L/QS-10 580 l/min nominal flow and IP65.

SKU: Festo-568655 Category:
Festo Solenoid Valves

Festo VMPA2-M1H-NS-PI Dual Normally Open Solenoid Valve

BrandFesto
Model IdentifierVMPA2-M1H-NS-PI
Official Part Number568655

Technical Overview

The Festo VMPA2-M1H-NS-PI is a 20 mm, dual normally open 3/2-way valve with mechanical spring reset and 24 V DC actuation. Manufacturer flow notes specify 550 l/min for MPA-S and 580 l/min for MPA-L installations. Its −0.9 to 8 bar working range, reversible flow and vacuum suitability are separate from the 3–8 bar pilot-pressure requirement. Switching times are 12 ms on and 25 ms off. The 100 g die-cast aluminium valve has NBR seals, signal indication, manual override and through-hole mounting, with IP65 protection and −5 to 50 °C ambient limits.

20 mm dual normally open 3/2 valve with mechanical spring reset, 24 V DC actuation, reversible flow and platform-specific nominal-flow ratings.

Key Features

  • Two normally open monostable 3/2-way functions with mechanical spring reset
  • 20 mm valve size and soft-sealed piston gate design
  • Nominal flow: MPA-S/QS-8 550 l/min; MPA-L/QS-10 580 l/min
  • 24 V DC operation with ±25% permissible voltage variation
  • −0.9 to 8 bar working pressure and separate 3–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • 12 ms switch-on and 25 ms switch-off times
  • Signal indication and detenting/non-detenting manual override
  • IP65 protection; 0.65 Nm maximum valve-mounting torque
  • 100 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient range

Provide two normally open pneumatic functions and vacuum suitability in a 20 mm MPA valve, with flow ratings matched to the terminal arrangement.

Technical Specification Matrix

ParameterValue
Valve function2x3/2 open monostable
Type of actuationElectrical
Valve size20 mm
Standard nominal flow rate (standardised to DIN 1343)550 l/min...580 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...0.8 MPa; -0.9 bar...8 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumYes
Note on standard nominal flow rateMPA-L: 580 l/min; MPA-S: 550 l/min
Standard nominal flow rate with QS-8550 l/min
Standard nominal flow rate with QS-10580 l/min
Switching time off25 ms
Switching time on12 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal900 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.65 Nm
Physical Weight (kg)0.1
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Normally Supplied Air-Purge Branches

A machine needs two air-purge branches that receive supply in their normal valve states, with electrical commands changing the respective routing. This dual normally open 3/2-way valve provides both functions in one 20 mm body with mechanical spring reset. Festo lists 550 l/min for MPA-S/QS-8 and 580 l/min for MPA-L/QS-10 installations, distinguishing the selected pneumatic arrangement.

Problem Solved

Two normally open functions consolidate purge-branch routing in one valve body, providing electrical commands and mechanical spring return for circuits designed around an open normal state.

2 × 3/2 normally open Mechanical spring reset 20 mm valve

2. Vacuum-Circuit Path Switching

A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.

Problem Solved

Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.

Vacuum suitability −0.9 bar 3–8 bar pilot

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 20 mm valve uses through-hole mounting with a specified 0.65 Nm maximum valve-mounting torque for installation.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override Signal indication 20 mm