Festo 543702 5/3 Closed-Centre Valve, ISO Size 1, 24 V DC

Festo 543702 5/3 Closed-Centre Valve, ISO Size 1, 24 V DC

Plug-in ISO 5599-2 size 1 valve with closed centre, 1200 l/min interlinked flow, external 3–10 bar pilot supply, 22 ms on/65 ms off timing and IP65/NEMA 4.

SKU: Festo-543702 Category:
Festo Solenoid Valves

Festo VSVA-B-P53C-ZD-D1-1T1L Solenoid Valve

BrandFesto
Model IdentifierVSVA-B-P53C-ZD-D1-1T1L
Official Part Number543702

Technical Overview

The Festo VSVA-B-P53C-ZD-D1-1T1L is an 42 mm closed-centre 5/3-way valve for plug-in ISO 5599-2 size 1 sub-base mounting. Its nominal interlinked flow is 1200 l/min, with separate ratings of 1700 l/min valve-only, 1400 l/min on an individual sub-base and 1690 l/min for a flow-optimized interlinked arrangement. The working range is −0.9 to 10 bar, with a 3–10 bar pilot-pressure requirement and external pilot supply. A 24 V DC, 1.6 W coil characteristic and 22 ms switch-on and 65 ms switch-off times define electrical switching. The 456 g aluminium/PA valve provides LED indication, manual override and IP65/NEMA 4 protection.

42 mm plug-in ISO 5599-2 size 1 closed-centre 5/3 valve with 1200 l/min nominal interlinked flow and 24 V DC actuation.

Key Features

  • 5/3-way closed-centre piston-gate function
  • 42 mm ISO 5599-2 size 1 plug-in sub-base interface
  • 1200 l/min standard nominal interlinked flow
  • 1700 l/min valve-only, 1400 l/min individual-sub-base and 1690 l/min flow-optimized linked ratings
  • −0.9 to 10 bar working range; separate 3–10 bar pilot pressure
  • External pilot supply; any working-flow direction
  • 24 V DC, 1.6 W coil characteristic with ±10% voltage tolerance
  • 22 ms switch-on and 65 ms switch-off; 72 mA nominal pick-up current per coil to 30 ms
  • LED indication and detenting/non-detenting/concealed override options
  • 456 g die-cast aluminium/PA body, IP65/NEMA 4 and −5 to 50 °C ambient range

Provide two directional commands and a closed centre state through an ISO 5599-2 size 1 valve with 1200 l/min interlinked flow.

Technical Specification Matrix

ParameterValue
Valve function5/3-way, closed
Type of actuationElectrical
Construction width42 mm
Standard nominal flow rate (standardised to DIN 1343)1200 l/min
pneumatic working portSub-base size 1 to ISO 5599-2; G3/8
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; NEMA 4
Exhaust-air functionCan be throttled; Via throttle plate; Via individual sub-base
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting; Concealed
Type of pilotingPiloted
Pilot air supplyExternal
Flow directionAny
Signal status displayLED
Pilot pressure0.3 MPa...1 MPa; 3 bar...10 bar
Flow rate of valve1700 l/min
Flow rate of valve on individual sub-base1400 l/min
Valve flow rate, pneumatically linked, flow optimized1690 l/min
Flow rate of pneumatically interlinked valve1200 l/min
Switching time off65 ms
Switching time on22 ms
Max. positive test pulse with 0 signal1400 µs
Max. negative test pulse with 1 signal900 µs
Nominal pick-up current per solenoid coil72 mA to 30 ms
Characteristic coil data24 V DC: 1.6 W
Immunity to surge2.5 kV
Pollution degree3
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Relative air humidity0 - 90%
Ambient temperature-5 °C...50 °C
Physical Weight (kg)0.456
Electrical connectionPlug-in; To ISO 5599-2
Type of mountingOn sub-base
Pilot air port 12/14Sub-base size 1 to ISO 5599-2
Pilot exhaust port 82/84Ducted; Not ducted as per standard; Either:
Pneumatic connection, port 1Sub-base size 1 to ISO 5599-2
Pneumatic connection, port 2Sub-base size 1 to ISO 5599-2
Pneumatic connection, port 3Sub-base size 1 to ISO 5599-2
Pneumatic connection, port 4Sub-base size 1 to ISO 5599-2
Pneumatic connection, port 5Sub-base size 1 to ISO 5599-2
Note on materialsRoHS compliant
Material sealsFluoro rubber; HNBR; NBR
Material housingDie-cast aluminium; PA
Material screwsGalvanised steel

Industrial Applications

1. Direction Control for a Double-Acting Transfer Cylinder

A transfer fixture needs to drive a double-acting cylinder in either direction and select a closed centre state between commands. The 5/3-way valve provides that three-position routing through a 42 mm ISO 5599-2 size 1 sub-base interface. Its 1200 l/min nominal interlinked flow and external 3–10 bar pilot supply define component conditions; load and leakage determine actual cylinder position retention.

Problem Solved

Three-position routing closes the working paths in the centre state, providing a defined intermediate valve condition between directional commands without guaranteeing leak-free retention of the connected actuator.

5/3 closed centre ISO size 1 1200 l/min interlinked

2. Sub-Atmospheric Working-Path Switching

A pneumatic circuit uses working pressures below atmosphere while retaining a positive-pressure pilot supply for valve actuation. The exact valve permits −0.9 to 10 bar working pressure and any flow direction, with a separate 3–10 bar pilot requirement. An external pilot supply provides the positive-pressure actuation condition, separating working-path conditions from the actuation supply.

Problem Solved

The documented working-pressure range permits sub-atmospheric circuit paths, while the separate pilot specification provides a clear positive-pressure condition for switching the valve.

−0.9 bar working limit 3–10 bar pilot Any flow direction

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The specified manual override options provide local actuation, while LED signal indication exposes the electrical command condition. The 42 mm plug-in ISO 5599-2 interface and sub-base mounting define how the valve integrates with the selected station.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override LED indication ISO 5599-2