Festo 153449 Check Valve, QS-6 to R1/8, 335 l/min

Festo 153449 Check Valve, QS-6 to R1/8, 335 l/min

Screw-in non-return valve with flow from QS-6 to male R1/8, 0.1 bar minimum opening differential, nickel-plated brass housing and 11 g weight.

SKU: Festo-153449 Category:
Festo Check Valves

Festo HB-1/8-QS-6 Check Valve

BrandFesto
Model IdentifierHB-1/8-QS-6
Official Part Number153449

Technical Overview

The Festo HB-1/8-QS-6 is a screw-in pneumatic check valve connecting a QS-6 push-in port to an R1/8 male thread. The HB flow direction runs from the push-in connection toward the threaded connection, with a non-return function opposing reverse flow. Standard nominal flow is 335 l/min, and the manufacturer specifies minimum differential pressures of 0.1 bar for opening and 0.2 bar for closing. The 11 g valve uses a nickel-plated brass housing and operates from −1 to 10 bar within a 0–60 °C ambient range. It is specified for compressed air to ISO 8573-1 [7:-:-], with lubricated operation permitted under the stated medium conditions.

QS-6 to R1/8 screw-in check valve with 335 l/min nominal flow and 0.1 bar minimum opening differential pressure.

Key Features

  • Non-return valve function
  • HB permitted flow direction: QS push-in connector toward male thread
  • QS-6 port 1 and R1/8 port 2
  • 335 l/min standard nominal flow to DIN 1343
  • 0.1 bar minimum opening differential pressure
  • 0.2 bar minimum closing differential pressure
  • −1 to 10 bar operating-pressure range
  • Screw-in mounting with nickel-plated brass housing
  • 11 g product weight and 0–60 °C ambient range

Permit flow from 6 mm tubing toward an R1/8 component port while opposing return flow through one compact screw-in valve.

Technical Specification Matrix

ParameterValue
Valve functionWith non-return function
Pneumatic connection, port 1QS-6
Pneumatic connection, port 2R1/8
Type of mountingScrew-in
Standard nominal flow rate (standardised to DIN 1343)335 l/min
Operating pressure-1 bar...10 bar
Ambient temperature0 °C...60 °C
Material housingBrass, nickel-plated
Operating mediumCompressed air to ISO 8573-1:2010 [7:-:-]
Min. diff. pressure, opening0.1 bar
Min. diff. pressure, closing0.2 bar
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
LABS (PWIS) conformityVDMA24364-B1/B2-L
Physical Weight (kg)0.011
Note on materialsRoHS compliant
Permitted flow directionQS push-in connector to male thread

Industrial Applications

1. Opposing Backflow from a Charged Branch

A pneumatic branch connected at the threaded side can remain pressurized when the upstream tubing supply falls. The HB valve permits charging flow from its QS-6 connection toward the R1/8 component port and opposes the reverse direction. Its documented opening and closing differential pressures characterize that passive non-return action without an electrical control signal.

Problem Solved

The non-return mechanism opposes discharge back through the supply connection when pressure reverses, providing a passive directional boundary between the tubing and charged branch.

QS to male-thread flow Non-return function 0.1 bar opening differential

2. Preventing Cross-feed between Air Supplies

A circuit feeds a common pneumatic volume from separately controlled branches and needs to oppose flow back into a lower-pressure branch. A check valve in each appropriately arranged inlet provides the non-return function. This screw-in version supplies a QS-6 tubing interface, R1/8 component connection and 335 l/min nominal flow rating for evaluating an individual branch connection.

Problem Solved

Directional check action opposes cross-feed into the connected supply branch, allowing a multi-branch circuit to use passive flow boundaries at its individual inlets.

Non-return function 335 l/min nominal R1/8 screw-in

3. Directional Flow in a Vacuum Branch

A vacuum circuit needs a passive valve that permits evacuation flow in one direction and opposes return flow when the pressure relationship changes. The documented −1 to 10 bar operating range includes negative pressure, while the HB direction runs from QS tubing toward the threaded port. The vacuum source and branch are arranged to use that permitted direction and the stated differential-pressure requirements.

Problem Solved

The passive non-return element provides a defined directional flow path in the vacuum circuit, using the documented negative-pressure range and differential-pressure behavior of the exact valve.

−1 bar range limit Passive non-return Defined flow direction