1. Two-Hand Command Inputs for a Machine Sequence
A machine safety controller needs to evaluate a suitable two-hand control device before starting a defined operation. Festo lists two-hand control as an application for this module. The eight PNP inputs can be grouped into channel pairs with selectable function modes, and their information is transmitted through PROFIsafe to the higher-level safety controller in the prescribed CPX arrangement.
Problem Solved
Configurable paired inputs provide the documented input-evaluation stage for the two-hand device, carrying its signals into the safety controller rather than starting the machine directly from ordinary unmonitored inputs.
Paired PNP inputs
11 function modes
PROFIsafe
2. Guard-Switch Evaluation at a Machine Access Point
A machine access guard uses a suitable multi-channel switch arrangement whose signals must reach the safety controller. Festo lists a safety door with two normally open switches among the module’s application examples. Configurable input pairs evaluate the signals, while wire-break, short-circuit and cross-circuit diagnostics provide documented electrical monitoring for the applicable operating modes.
Problem Solved
Paired input evaluation and electrical fault diagnostics provide a monitored interface for the guard-switch signals, enabling the higher-level safety controller to use those observations in the machine architecture.
Multi-channel guard input
Cross-circuit diagnostics
PNP logic
3. Emergency-Stop Input Monitoring across a CPX Station
An automation station collects emergency-stop switch signals for a higher-order PROFIsafe controller. The module supplies eight positive-switching inputs and supports selectable channel-pair evaluation, with channel LEDs and group diagnostics for observing the input paths. Its communication, process-data and self-test diagnostics complement the electrical channel checks, making the input module’s specified fault information available within the compatible CPX system.
Problem Solved
The PROFIsafe input stage carries the emergency-stop device signals and diagnostic information to the safety controller, supporting evaluation of the input chain within the complete stopping architecture.
Eight digital inputs
Channel diagnostics