Festo 527458 Vacuum Pressure Sensor, 0 to −1 bar, PNP NO

Piezoresistive threshold sensor with teach-in, QS-6 connection, three-pin M8 plug, ±0.5% FS accuracy and 2 ms switching times on a 15–30 V DC supply.

SKU: Festo-527458 Category:
Festo Pressure Sensors And Vacuum Sensors

Festo SDE5-V1-O-Q6-P-M8 Vacuum Pressure Sensor

BrandFesto
Model IdentifierSDE5-V1-O-Q6-P-M8
Official Part Number527458

Technical Overview

The Festo SDE5-V1-O-Q6-P-M8 measures relative pressure from 0 to −1 bar using a piezoresistive sensing element. Its PNP normally open output implements a teach-in threshold with fixed 2% FS hysteresis and specified 2 ms switch-on and switch-off times. Accuracy is ±0.5% FS, with ±0.3% FS repetition accuracy under the manufacturer's conditions. A QS-6 pneumatic connection links the sensing line, while a three-pin A-coded M8 plug supplies 15–30 V DC power and the switching output. The 19 g sensor has a yellow switching LED, IP40 protection and Class 4 cleanroom suitability, with 0 to +50 °C ambient and media operation.

0 to −1 bar relative-pressure sensor with PNP normally open threshold output, teach-in, QS-6 pneumatic connection and three-pin M8 plug.

Key Features

  • Piezoresistive measurement of relative pressure from 0 to −1 bar
  • PNP normally open switching output
  • Threshold function with fixed 2% FS hysteresis
  • Teach-in adjustment across 0–100% threshold setting range
  • ±0.5% FS accuracy and ±0.3% FS repetition accuracy
  • 2 ms switch-on and 2 ms switch-off times
  • QS-6 pneumatic connection and three-pin A-coded M8 plug
  • 15–30 V DC supply and 100 mA maximum output current
  • 19 g product weight with yellow switching LED
  • IP40 protection, Class 4 cleanroom suitability and 0 to +50 °C ambient/media range

Provide a taught vacuum-threshold signal through a PNP output with 2 ms switching times and a direct QS-6 sensing-line connection.

Technical Specification Matrix

ParameterValue
ApprovalRCM; c UL us - Recognised (Oil)
CE mark (see declaration of conformity)To EU EMC Directive; In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC; To UK RoHS instructions
Note on materialsRoHS compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 MPa; 0 bar; 0 psi
End value for pressure measuring range-0.1 MPa; -1 bar; -14.5 psi
Overload pressure0.5 MPa; 5 bar; 72.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C...50 °C
Ambient temperature0 °C...50 °C
Accuracy in ± % FS0.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching outputPNP
Switching functionThreshold value with fixed hysteresis
Switching element functionN/O contact
Hysteresis in ± %FS2 %FS
Switch-on time2 ms
Switch-off time2 ms
Max. output current100 mA
Voltage drop1.8 V
Short circuit current ratingYes
Overload protectionYes
Operational voltage range DC15 V...30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlug
Electrical connection 1, connector systemM8x1, A-coded, to EN 61076-2-104
Electrical connection 1, number of connections/cores3
Electrical connection 1, type of mountingSnap-locking; Screw-type lock; Not rotatable
Electrical connection 1, compatible type of mountingCompatible with latching lock; Compatible with rotatable screw-type lock
Max. cable length30 M
Type of mountingWith accessories
Mounting positionAny
Pneumatic connectionQS-6
Physical Weight (kg)0.019
Material housingReinforced PA; Reinforced POM
Material sealing ringFluoro rubber; NBR
Switching status indicationYellow LED
Setting optionsTeach-in
Setting range threshold value0 %...100 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1

Industrial Applications

1. Vacuum Pickup Confirmation Before Transfer

A vacuum-handling station needs a pressure-based signal before proceeding with a transfer command. The sensor measures the local vacuum line through QS-6 and changes its PNP threshold output at the taught setting within the 0 to −1 bar range. The fixed hysteresis and 2 ms component switching times characterize the signal behavior, while cup sealing and load security remain properties of the complete handling system.

Problem Solved

The taught threshold converts local vacuum pressure into a discrete controller signal, supporting a pickup-confirmation step before the handling sequence advances to the transfer command.

0 to −1 bar PNP threshold QS-6

2. Monitoring Vacuum Decay During a Release Sequence

After a vacuum tool receives a release command, the controller needs to observe whether the sensing-line vacuum crosses the selected threshold toward atmospheric pressure. This relative-pressure sensor provides that discrete switching result over its 0 to −1 bar range. Its 2 ms switch-off time characterizes the sensor component, rather than establishing when the workpiece has mechanically separated from the suction cup.

Problem Solved

Threshold switching supplies pressure-state feedback during the release sequence, helping the controller distinguish a vacuum line that remains beyond the setting from one that has crossed it.

Relative vacuum pressure 2 ms switch-off Threshold feedback

3. Vacuum Branch Loss Indication

A machine needs a discrete indication when a monitored vacuum branch no longer remains on the expected side of a pressure threshold during a commanded hold period. The SDE5 supplies a PNP normally open output, fixed hysteresis and a local yellow switching LED. The controller can use that signal as a pressure-state input for its branch-monitoring logic without treating the sensor as a quantitative leak-rate instrument.

Problem Solved

A local threshold signal makes a changed vacuum condition available to the control system, while the LED provides visible switching information for investigation of the affected branch.

PNP normally open Fixed hysteresis Yellow LED