Festo 533342 5/2 Solenoid Valve, 10 mm, 24 V DC, 360 l/min

Festo 533342 5/2 Solenoid Valve, 10 mm, 24 V DC, 360 l/min

MPA single-solenoid valve with pneumatic spring reset, reversible flow, vacuum suitability, 3–8 bar pilot pressure and 11 ms on/20 ms off switching.

SKU: Festo-533342 Category:
Festo Solenoid Valves

Festo VMPA1-M1H-M-PI Solenoid Valve

BrandFesto
Model IdentifierVMPA1-M1H-M-PI
Official Part Number533342

Technical Overview

The Festo VMPA1-M1H-M-PI is a 10 mm single-solenoid 5/2-way valve with pneumatic spring reset and 24 V DC actuation. Its soft-sealing piston-gate design provides reversible flow and documented vacuum suitability across a −0.9 to 10 bar working range. Standard nominal flow is 360 l/min, also specified for a QS-6 arrangement; that rating does not establish that fittings are supplied. A separate 3–8 bar pilot-pressure requirement governs pneumatic actuation. Switching times are 11 ms on and 20 ms off. The 49 g die-cast aluminium valve includes signal indication and detenting/non-detenting override, with through-hole mounting and IP65 protection.

10 mm single-solenoid 5/2 valve with pneumatic spring reset, 360 l/min nominal flow, 24 V DC actuation and vacuum suitability.

Key Features

  • Single-solenoid 5/2-way function with pneumatic spring reset
  • 10 mm valve size and soft-sealed piston-gate design
  • 360 l/min standard nominal flow, also specified with QS-6 arrangement
  • 24 V DC operation with ±25% permissible voltage variation
  • −0.9 to 10 bar working range and separate 3–8 bar pilot pressure
  • Reversible flow direction and documented vacuum suitability
  • 11 ms switch-on and 20 ms switch-off times
  • Signal indication and detenting/non-detenting manual override
  • IP65 protection; 0.25 Nm maximum valve-mounting torque
  • 49 g die-cast aluminium body with NBR seals; −5 to 50 °C ambient/media range

Route a double-acting pneumatic circuit through a 10 mm valve with pneumatic spring reset, reversible flow and vacuum suitability.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, single solenoid
Type of actuationElectrical
Valve size10 mm
Standard nominal flow rate (standardised to DIN 1343)360 l/min
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Type of resetPneumatic spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; To IEC 60529
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting
Type of pilotingPiloted
Flow directionReversible
lapOverlap
Signal status displayYes
Pilot pressure0.3 MPa...0.8 MPa; 3 bar...8 bar
Suitability for vacuumYes
Standard nominal flow rate with QS-6360 l/min
Switching time off20 ms
Switching time on11 ms
Max. positive test pulse with 0 signal400 µs
Max. negative test pulse with 1 signal200 µs
Permissible voltage fluctuations+/-25%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Storage temperature-20 °C...40 °C
Media temperature-5 °C...50 °C
Relative air humidityMax. 90% at 40 °C
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting0.25 Nm
Physical Weight (kg)0.049
Type of mountingWith through-hole
Note on materialsRoHS compliant
Material sealsNBR
Material housingDie-cast aluminium

Industrial Applications

1. Direction Control for a Double-Acting Transfer Cylinder

A transfer fixture needs to alternate supply and exhaust between two cylinder chambers. The valve provides a single-solenoid 5/2-way routing function with pneumatic spring reset, using 24 V DC electrical actuation and a separate 3–8 bar pilot-pressure requirement. Its 360 l/min standard nominal flow and 10 mm valve size define the selected component at the pneumatic station.

Problem Solved

Five-port switching supplies the two directional routing states needed by the cylinder, while pneumatic spring reset provides the specified alternate state for the machine command sequence.

5/2 single solenoid Pneumatic spring reset 360 l/min nominal

2. Vacuum-Circuit Path Switching

A handling circuit needs a directional valve whose working paths can operate below atmospheric pressure. This model is explicitly suitable for vacuum and permits working pressure down to −0.9 bar with reversible flow. A separate 3–8 bar pilot requirement supplies the actuation condition while the working circuit follows the selected vacuum and venting connections.

Problem Solved

Documented vacuum suitability permits switching of sub-atmospheric working paths, while the separate pilot-pressure range defines the positive-pressure actuation needed for that vacuum circuit arrangement.

Vacuum suitability −0.9 bar 3–8 bar pilot

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The detenting and non-detenting manual override provides local actuation, while signal indication makes the commanded condition visible. The 10 mm valve uses through-hole mounting with a specified 0.25 Nm maximum valve-mounting torque for installation.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override Signal indication 10 mm