Festo 539156 5/2 Double-Solenoid Valve, ISO 26 mm, 24 V DC

Plug-in ISO 15407-2 valve with 1100 l/min interlinked flow, 1400 l/min valve-only flow, 18 ms reversal time, internal/external pilot options and IP65/NEMA 4.

SKU: Festo-539156 Category:
Festo Solenoid Valves

Festo VSVA-B-B52-ZD-A1-1T1L Solenoid Valve

BrandFesto
Model IdentifierVSVA-B-B52-ZD-A1-1T1L
Official Part Number539156

Technical Overview

The Festo VSVA-B-B52-ZD-A1-1T1L is a 26 mm double-solenoid 5/2-way valve for plug-in ISO 15407-2 sub-base mounting. Its nominal interlinked flow is 1100 l/min, with separate ratings of 1400 l/min valve-only, 1200 l/min on an individual sub-base and 1350 l/min for a flow-optimized interlinked arrangement. The working range is −0.9 to 10 bar, with a 3–10 bar pilot-pressure requirement and internal or external pilot supply determined by the assembly. A 24 V DC, 1.6 W coil characteristic and 18 ms reversal time define electrical switching. The 276 g aluminium/PA valve provides LED indication, manual override and IP65/NEMA 4 protection.

26 mm plug-in ISO 15407-2 double-solenoid 5/2 valve with 1100 l/min nominal interlinked flow, 24 V DC actuation and 18 ms reversal time.

Key Features

  • Double-solenoid 5/2-way piston-gate function
  • 26 mm ISO 15407-2 plug-in sub-base interface
  • 1100 l/min standard nominal interlinked flow
  • 1400 l/min valve-only, 1200 l/min individual-sub-base and 1350 l/min flow-optimized linked ratings
  • −0.9 to 10 bar working range; separate 3–10 bar pilot pressure
  • Internal or external pilot supply according to assembly; any flow direction
  • 24 V DC, 1.6 W coil characteristic with ±10% voltage tolerance
  • 18 ms reversal time and 100% duty cycle
  • LED indication and detenting/non-detenting/concealed override options
  • 276 g die-cast aluminium/PA body, IP65/NEMA 4 and −5 to 50 °C ambient range

Route a double-acting circuit through a 26 mm plug-in ISO valve with 1100 l/min interlinked flow and an 18 ms reversal time.

Technical Specification Matrix

ParameterValue
Valve function5/2-way, double solenoid
Type of actuationElectrical
Construction width26 mm
Standard nominal flow rate (standardised to DIN 1343)1100 l/min
pneumatic working portSub-base size 26 mm to ISO 15407-2; connection configuration determined by the sub-base
Operating voltage24 V DC
Operating pressure-0.09 MPa...1 MPa; -0.9 bar...10 bar
DesignPiston gate valve
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; NEMA 4
Exhaust-air functionCan be throttled; Via throttle plate; Via individual sub-base
Sealing principleSoft
Mounting positionAny
Manual overrideDetenting; Non-detenting; Concealed
Type of pilotingPiloted
Pilot air supplyExternal; Internal
Flow directionAny
lapOverlap
Signal status displayLED
Pilot pressure0.3 MPa...1 MPa; 3 bar...10 bar
Flow rate of valve1400 l/min
Flow rate of valve on individual sub-base1200 l/min
Valve flow rate, pneumatically linked, flow optimized1350 l/min
Flow rate of pneumatically interlinked valve1100 l/min
Switching time reversal18 ms
Duty cycle100%
Max. positive test pulse with 0 signal1200 µs
Max. negative test pulse with 1 signal1100 µs
Max. current consumption72 mA
Nominal operating voltage DC24 V
Characteristic coil data24 V DC: 1.6 W
Immunity to surge2.5 kV
Pollution degree3
Permissible voltage fluctuations+/-10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Relative air humidity0 - 90%
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...50 °C
Physical Weight (kg)0.276
Electrical connectionPlug-in; To ISO 15407-2
Type of mountingOn sub-base
Pilot air port 12/14Sub-base size 26 mm to ISO 15407-2
Pilot exhaust port 82/84Ducted; Not ducted as per standard; Either:
Pneumatic connection, port 1Sub-base size 26 mm to ISO 15407-2
Pneumatic connection, port 2Sub-base size 26 mm to ISO 15407-2
Pneumatic connection, port 3Sub-base size 26 mm to ISO 15407-2
Pneumatic connection, port 4Sub-base size 26 mm to ISO 15407-2
Pneumatic connection, port 5Sub-base size 26 mm to ISO 15407-2
Note on materialsRoHS compliant
Material sealsFluoro rubber; HNBR; NBR
Material housingDie-cast aluminium; PA
Material screwsGalvanised steel

Industrial Applications

1. Direction Control for a Double-Acting Transfer Cylinder

A transfer fixture needs to alternate pressure and exhaust between the chambers of a double-acting cylinder. The double-solenoid 5/2-way valve provides the two routing states through a 26 mm ISO 15407-2 sub-base interface. Its 1100 l/min nominal interlinked flow and separate 3–10 bar pilot requirement define component conditions, with an 18 ms reversal time specified for the valve.

Problem Solved

Five-port switching supplies the two directional routing states needed by the cylinder, with two solenoid commands providing the electrical interface for the machine sequence.

5/2 double solenoid ISO 26 mm 1100 l/min interlinked

2. Sub-Atmospheric Working-Path Switching

A pneumatic circuit uses working pressures below atmosphere while retaining a positive-pressure pilot supply for valve actuation. The exact valve permits −0.9 to 10 bar working pressure and any flow direction, with a separate 3–10 bar pilot requirement. Internal or external pilot arrangements depend on the selected terminal configuration, separating working-path conditions from the actuation supply.

Problem Solved

The documented working-pressure range permits sub-atmospheric circuit paths, while the separate pilot specification provides a clear positive-pressure condition for switching the valve.

−0.9 bar working limit 3–10 bar pilot Any flow direction

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The specified manual override options provide local actuation, while LED signal indication exposes the electrical command condition. The 26 mm plug-in ISO 15407-2 interface and sub-base mounting define how the valve integrates with the selected station.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.