Festo 547068 Dual NC 3/2 Valve, ISO 26 mm, External Pilot

ISO 15407-1 dual normally closed valve with pneumatic spring reset, 900 l/min interlinked flow, 24 V DC 1.8 W coil, Type C connection and external pilot.

SKU: Festo-547068 Category:
Festo Solenoid Valves

Festo VSVA-B-T32C-AZH-A1-1C1 Dual Normally Closed Solenoid Valve

BrandFesto
Model IdentifierVSVA-B-T32C-AZH-A1-1C1
Official Part Number547068

Technical Overview

The Festo VSVA-B-T32C-AZH-A1-1C1 combines two normally closed monostable 3/2-way functions in a 26 mm ISO 15407-1 valve with pneumatic spring reset. Interlinked nominal flow is 900 l/min, with separate 1000 l/min individual-sub-base and 1250 l/min valve-only ratings. External pilot air at 3–10 bar serves the switching mechanism, distinct from the 2–10 bar working range. The 24 V DC, 1.8 W coil characteristic uses a Type C interface without PE conductor. Component timings are 20 ms on and 28 ms off. The 305 g aluminium valve includes LED indication, non-detenting override and IP65/NEMA 4 protection, with a 2 Nm mounting-torque limit.

26 mm ISO dual normally closed 3/2 valve with pneumatic spring reset, 900 l/min interlinked flow, external pilot and Type C electrical interface.

Key Features

  • Two normally closed monostable 3/2-way functions with pneumatic spring reset
  • 26 mm ISO 15407-1 / VDMA 24563 size 01 interface
  • 900 l/min nominal interlinked flow; 1000 l/min individual-sub-base flow
  • 1250 l/min valve-only flow and 9 mm nominal size
  • 2–10 bar working pressure; external pilot supply at 3–10 bar
  • 24 V DC, 1.8 W coil characteristic with −15%/+10% voltage tolerance
  • Type C interface to DIN EN 175301-803, without PE conductor
  • 20 ms on and 28 ms off; LED indication and non-detenting override
  • IP65/NEMA 4 protection and 2 Nm maximum valve-mounting torque
  • 305 g aluminium housing with HNBR/NBR seals; −5 to 50 °C ambient/media range

Control two normally closed branches through an ISO 26 mm valve with pneumatic spring reset and 900 l/min interlinked flow.

Technical Specification Matrix

ParameterValue
Valve function2x3/2 closed monostable
Type of actuationElectrical
Valve size26 mm
Standard nominal flow rate (standardised to DIN 1343)900 l/min
pneumatic working portSub-base size 26 mm to ISO 15407-1; Sub-base size 01 to VDMA 24563; G1/4
Operating voltage24 V DC
Operating pressure0.2 MPa...1 MPa; 2 bar...10 bar
DesignPiston gate valve
Type of resetPneumatic spring
Approvalc UL us - Recognised (Oil)
Degree of protectionIP65; NEMA 4
Nominal size9 mm
Exhaust-air functionCan be throttled
Sealing principleSoft
Mounting positionAny
Conforms to standardISO 15407-1; VDMA 24563
Manual overrideNon-detenting
Type of pilotingPiloted
Pilot air supplyExternal
Flow directionNon-reversible
lapOverlap
Signal status displayLED
Pilot pressure0.3 MPa...1 MPa; 3 bar...10 bar
Flow rate of valve1250 l/min
Flow rate of valve on individual sub-base1000 l/min
Flow rate of pneumatically interlinked valve900 l/min
Switching time off28 ms
Switching time on20 ms
Duty cycle100%
Max. positive test pulse with 0 signal1800 µs
Max. negative test pulse with 1 signal800 µs
Characteristic coil data24 V DC: 1.8 W
Permissible voltage fluctuations-15% / +10%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will; always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN; 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C...50 °C
Relative air humidity0 - 90%
Sound pressure level85 dB(A)
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Ambient temperature-5 °C...50 °C
Max. tightening torque for valve mounting2 Nm
Physical Weight (kg)0.305
Electrical connectionType C; To DIN EN 175301-803; Without PE conductor
Type of mountingOn sub-base
Auxiliary pilot air port 12Sub-base size 26 mm to ISO 15407-1
Auxiliary pilot air port 14Sub-base size 26 mm to ISO 15407-1
Pilot exhaust port 82/84Ducted; Not ducted as per standard
Pneumatic connection, port 1Sub-base size 26 mm to ISO 15407-1
Pneumatic connection, port 2Sub-base size 26 mm to ISO 15407-1
Pneumatic connection, port 3Sub-base size 26 mm to ISO 15407-1
Pneumatic connection, port 4Sub-base size 26 mm to ISO 15407-1
Pneumatic connection, port 5Sub-base size 26 mm to ISO 15407-1
Pilot control interfaceTo ISO 15218
Note on materialsRoHS compliant
Material sealsHNBR; NBR
Material housingDie-cast aluminium
Material screwsSteel; Galvanised

Industrial Applications

1. Fixture Clamp and Ejector Sequencing

An assembly fixture uses separate single-acting clamp and ejector circuits at different points in its cycle. The dual normally closed 3/2-way functions provide two pneumatic switching paths in one 26 mm body, with pneumatic spring reset. The 900 l/min nominal flow, 2–10 bar working range and separate 3–10 bar pilot pressure provide the selected valve data for the station.

Problem Solved

Two monostable switching functions consolidate the clamp and ejector commands in one valve, supporting separate fixture steps with documented working and pilot pressure conditions.

2 × 3/2 normally closed Pneumatic spring reset 26 mm

2. Electrical Commands to Two Pneumatic Pilot Branches

A machine uses two downstream pneumatic control elements and needs separate electrically commanded pilot branches. This valve provides two normally closed monostable functions under 24 V DC actuation, with non-reversible working flow. Its 20 ms on and 28 ms off component times characterize the command stage, while the supplied pilot-air pressure must remain within the separate 3–10 bar range.

Problem Solved

Two electrical-to-pneumatic switching paths provide individual commands for downstream control elements, consolidating their pilot-branch routing at one compact MPA valve position.

Two NC functions 24 V DC 20 ms on / 28 ms off

3. Valve-Station Commissioning

During assembly of a pneumatic valve station, technicians need to exercise routing states and correlate electrical commands with the installed valve. The non-detenting manual override provides local actuation, while LED indication exposes the electrical command condition. The 26 mm ISO 15407-1 interface and 2 Nm mounting-torque limit provide specific installation data for this dual-function valve.

Problem Solved

Manual actuation and visible signal indication support local routing checks during commissioning, helping technicians relate the electrical command to the selected pneumatic path at the valve station.

Manual override Signal indication 26 mm