1. Fixture Clamp and Ejector Sequencing
A compact assembly fixture uses separate single-acting clamp and ejector circuits at different points in its cycle. The dual normally closed 3/2-way functions provide two supply-and-exhaust switching paths in one 10 mm valve body. Mechanical spring reset returns each function, while M5 connections and the three-pin M8 interface define the fixture's pneumatic and electrical connections.
Problem Solved
Two monostable switching functions consolidate the clamp and ejector air commands in one compact valve, supporting separate process steps without using two individual valve bodies.
2 × 3/2-way NC
10 mm body
M5 ports
2. Two-Zone Air-Blast Commands
A small packaging station directs compressed-air blasts to two separate process points, such as a part-release point and a tooling surface. Two normally closed 3/2-way functions let the machine sequence command the respective air circuits. The documented 8 ms switch-on and 11 ms switch-off times provide valve timing information for planning those commands alongside tubing and nozzle response.
Problem Solved
Separate normally closed air paths support two timed blast commands in one valve package, with published switching times providing a concrete basis for the pneumatic sequence.
2 pneumatic functions
8 ms on
11 ms off
3. Electrical-to-Pneumatic Pilot Signal Conversion
A machine uses pneumatic commands to actuate two downstream control functions. The dual 3/2-way valve converts 24 V DC electrical actuation into two normally closed pneumatic switching paths, with spring reset and M5 connections. Its internal pilot supply and compact manifold mounting support grouping these signal-conversion functions with the machine's other pneumatic controls within the 2.5–8 bar operating range.
Problem Solved
A compact dual-function valve links electrical sequence outputs to pneumatic command circuits, while spring reset supplies a defined monostable return action for each switching path.
24 V DC
Internal pilot
Spring reset