Contact Us:
sales@axmatic.com

IM12-02B-N-ZW0 Inductive Proximity Sensors – SICK Sensor

$ 61.87

SKU SICK 6021124 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6021124
Inductive proximity Sensor Model: IM12-02B-N-ZW0
OEM Spec Ref 

Features

Housing Cylindrical thread design
Thread size M12 x 1
Diameter Ø 12 mm
Sensing range Sn 2 mm
Safe sensing range Sa 1.62 mm
Installation type Flush
Switching frequency 1,200 Hz
Connection type Cable, 2-wire, 2 m
Switching output NAMUR
Output function NC
Enclosure rating IP67 1)
Special applications Explosive areas
  • 1) According to EN 60529.

Mechanics/electronics

Supply voltage 7.5 V DC … 25 V DC 1)
Current consumption 30 mA 1)
Hysteresis 1 % … 15 %
Temperature drift (of Sr) ± 10 %
EMC According to EN 60947-5-6
Current consumption, sensor is activated ≤ 1 mA
Current consumption, sensor is not activated ≥ 2.2 mA
Cable material PVC
Conductor size 0.34 mm²
Cable diameter Ø 4.9 mm
Cable resistance 50 Ω
Shock and vibration resistance 30 g, 11 ms / 10 … 55 Hz, 1 mm
Ambient operating temperature –20 °C … +70 °C
Housing material Brass, nickel-plated
Sensing face material Plastic, PTB
Housing length 30 mm
Thread length 29 mm
Tightening torque, max. 7 Nm
Weight + 130 g
Items supplied Mounting nut, brass, nickel-plated (2x)
Type approval certificate PTB 03 ATEX 2037
Ex area category 1G
Input voltage Umax. 15 V 2)
Input power Pi max. 120 mW 2)
Input current Imax. 50 mA 2)
Internal capacitance Ci max. 140 nF 2)
Internal inductance Li max. 340 µH 2)
Nominal voltage 8.2 V DC 3)
Device labeling II 1G Ex ia IIC T6 Ga Ta –20 °C … +70 °C
  • 1) When used outside the hazardous area.
  • 2) For connection to a separately certified intrinsically safe circuit only.
  • 3) 1 kΩ.

Additional information