The central processing units (CPUs) are the heart of the SIMATIC S7-1500. They execute the user program and network the controller with other automation components.
Thanks to numerous innovations, the CPUs of the SIMATIC S7-1500 deliver the ultimate plus in productivity and efficiency. The hardware is extremely compact and certified to IP20 or IP65/67 standard. These highly integrated, highly versatile modules save space in and around the cabinet and reduce the spare parts inventory costs.
Siemens PLC S7-1500 Product Specifications:
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1ps” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Article Number | 6ES7513-1AL02-0AB0 |
Product type designation | CPU 1513-1 PN |
HW functional status | FS03 |
Firmware version | V2.9 |
Product function | |
● I&M data | Yes; I&M0 to I&M3 |
● Isochronous mode | Yes; Distributed and central; with minimum OB 6x cycle of 500 µs (distributed) and 1 ms (central) |
Engineering with | |
● STEP 7 TIA Portal configurable/integrated from version | V17 (FW V2.9) / V15 (FW V2.5) or higher; with older TIA Portal versions configurable as 6ES7513-1AL01-0AB0 |
Configuration control | |
via dataset | Yes |
Display | |
Screen diagonal [cm] | 3.45 cm |
Control elements | |
Number of keys | 8 |
Mode buttons | 2 |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
Reverse polarity protection | Yes |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms |
● Repeat rate, min. | 1/s |
Input current | |
Current consumption (rated value) | 0.7 A |
Current consumption, max. | 0.95 A |
Inrush current, max. | 1.9 A; Rated value |
I²t | 0.02 A²·s |
Power | |
Infeed power to the backplane bus | 10 W |
Power consumption from the backplane bus (balanced) | 5.5 W |
Power loss | |
Power loss, typ. | 5.7 W |
Memory | |
Number of slots for SIMATIC memory card | 1 |
SIMATIC memory card required | Yes |
Work memory | |
● integrated (for program) | 300 kbyte |
● integrated (for data) | 1.5 Mbyte |
Load memory | |
● Plug-in (SIMATIC Memory Card), max. | 32 Gbyte |
Backup | |
● maintenance-free | Yes |
CPU processing times | |
for bit operations, typ. | 40 ns |
for word operations, typ. | 48 ns |
for fixed point arithmetic, typ. | 64 ns |
for floating point arithmetic, typ. | 256 ns |
CPU-blocks | |
Number of elements (total) | 4 000; Blocks (OB, FB, FC, DB) and UDTs |
DB | |
● Number range | 1 … 60 999; subdivided into: number range that can be used by the user: 1 … 59 999, and number range of DBs created via SFC 86: 60 000 … 60 999 |
● Size, max. | 1.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
FB | |
● Number range | 0 … 65 535 |
● Size, max. | 300 kbyte |
FC | |
● Number range | 0 … 65 535 |
● Size, max. | 300 kbyte |
OB | |
● Size, max. | 300 kbyte |
● Number of free cycle OBs | 100 |
● Number of time alarm OBs | 20 |
● Number of delay alarm OBs | 20 |
● Number of cyclic interrupt OBs | 20; With minimum OB 3x cycle of 500 µs |
● Number of process alarm OBs | 50 |
● Number of DPV1 alarm OBs | 3 |
● Number of isochronous mode OBs | 2 |
● Number of technology synchronous alarm OBs | 2 |
● Number of startup OBs | 100 |
● Number of asynchronous error OBs | 4 |
● Number of synchronous error OBs | 2 |
● Number of diagnostic alarm OBs | 1 |
Nesting depth | |
● per priority class | 24 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC counter | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
S7 times | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
IEC timer | |
● Number | Any (only limited by the main memory) |
Retentivity | |
— adjustable | Yes |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB |
Extended retentive data area (incl. timers, counters, flags), max. | 1.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF |
Flag | |
● Size, max. | 16 kbyte |
● Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
Data blocks | |
● Retentivity adjustable | Yes |
● Retentivity preset | No |
Local data | |
● per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area | |
Number of IO modules | 2 048; max. number of modules / submodules |
I/O address area | |
● Inputs | 32 kbyte; All inputs are in the process image |
● Outputs | 32 kbyte; All outputs are in the process image |
per integrated IO subsystem | |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
per CM/CP | |
— Inputs (volume) | 8 kbyte |
— Outputs (volume) | 8 kbyte |
Subprocess images | |
● Number of subprocess images, max. | 32 |
Hardware configuration | |
Number of distributed IO systems | 32; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) |
Number of DP masters | |
● Via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total |
Number of IO Controllers | |
● integrated | 1 |
● Via CM | 6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total |
Rack | |
● Modules per rack, max. | 32; CPU + 31 modules |
● Number of lines, max. | 1 |
PtP CM | |
● Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day | |
Clock | |
● Type | Hardware clock |
● Backup time | 6 wk; At 40 °C ambient temperature, typically |
● Deviation per day, max. | 10 s; Typ.: 2 s |
Operating hours counter | |
● Number | 16 |
Clock synchronization | |
● supported | Yes |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes |
Interfaces | |
Number of PROFINET interfaces | 1 |
1. Interface | |
Interface types | |
● RJ 45 (Ethernet) | Yes; X1 |
● Number of ports | 2 |
● integrated switch | Yes |
Protocols | |
● IP protocol | Yes; IPv4 |
● PROFINET IO Controller | Yes |
● PROFINET IO Device | Yes |
● SIMATIC communication | Yes |
● Open IE communication | Yes; Optionally also encrypted |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller | |
Services | |
— PG/OP communication | Yes |
— Isochronous mode | Yes |
— Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Prioritized startup | Yes; Max. 32 PROFINET devices |
— Number of connectable IO Devices, max. | 128; In total, up to 512 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET |
— Of which IO devices with IRT, max. | 64 |
— Number of connectable IO Devices for RT, max. | 128 |
— of which in line, max. | 128 |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
— Number of IO Devices per tool, max. | 8 |
— Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
Update time for IRT | |
— for send cycle of 250 µs | 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 500 µs of the isochronous OB is decisive |
— for send cycle of 500 µs | 500 µs to 8 ms |
— for send cycle of 1 ms | 1 ms to 16 ms |
— for send cycle of 2 ms | 2 ms to 32 ms |
— for send cycle of 4 ms | 4 ms to 64 ms |
— With IRT and parameterization of “odd” send cycles | Update time = set “odd” send clock (any multiple of 125 µs: 375 µs, 625 µs … 3 875 µs) |
Update time for RT | |
— for send cycle of 250 µs | 250 µs to 128 ms |
— for send cycle of 500 µs | 500 µs to 256 ms |
— for send cycle of 1 ms | 1 ms to 512 ms |
— for send cycle of 2 ms | 2 ms to 512 ms |
— for send cycle of 4 ms | 4 ms to 512 ms |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes |
— Isochronous mode | No |
— IRT | Yes |
— PROFIenergy | Yes; per user program |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 4 |
— activation/deactivation of I-devices | Yes; per user program |
— Asset management record | Yes; per user program |
Interface types | |
RJ 45 (Ethernet) | |
● 100 Mbps | Yes |
● Autonegotiation | Yes |
● Autocrossing | Yes |
● Industrial Ethernet status LED | Yes |
Protocols | |
PROFIsafe | No |
Number of connections | |
● Number of connections, max. | 128; via integrated interfaces of the CPU and connected CPs / CMs |
● Number of connections reserved for ES/HMI/web | 10 |
● Number of connections via integrated interfaces | 88 |
● Number of S7 routing paths | 16 |
Redundancy mode | |
● H-Sync forwarding | Yes |
Media redundancy | |
— Media redundancy | only via 1st interface (X1) |
— MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
— MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
— MRPD | Yes; Requirement: IRT |
— Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
— Number of stations in the ring, max. | 50 |
SIMATIC communication | |
● PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
● S7 routing | Yes |
● S7 communication, as server | Yes |
● S7 communication, as client | Yes |
● User data per job, max. | See online help (S7 communication, user data size) |
Open IE communication | |
● TCP/IP | Yes |
— Data length, max. | 64 kbyte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes |
— Data length, max. | 64 kbyte |
● UDP | Yes |
— Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
— UDP multicast | Yes; Max. 5 multicast circuits |
● DHCP | Yes |
● DNS | Yes |
● SNMP | Yes |
● DCP | Yes |
● LLDP | Yes |
● Encryption | Yes; Optional |
Web server | |
● HTTP | Yes; Standard and user pages |
● HTTPS | Yes; Standard and user pages |
OPC UA | |
● Runtime license required | Yes; “Small” license required |
● OPC UA Client | Yes |
— Application authentication | Yes |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | “anonymous” or by user name & password |
— Number of connections, max. | 4 |
— Number of nodes of the client interfaces, max. | 1 000 |
— Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 |
— Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
— Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 |
— Number of simultaneous calls of the client instructions per connection (except OPC_UA_ReadList,OPC_UA_WriteList,OPC_UA_MethodCall), max. | 1 |
— Number of simultaneous calls of the client instructions OPC_UA_ReadList,OPC_UA_WriteList and OPC_UA_MethodCall, max. | 5 |
— Number of registerable nodes, max. | 5 000 |
— Number of registerable method calls of OPC_UA_MethodCall, max. | 100 |
— Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 |
● OPC UA Server | Yes; Data access (read, write, subscribe), method call, custom address space |
— Application authentication | Yes |
— Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
— User authentication | “anonymous” or by user name & password |
— GDS support (certificate management) | Yes |
— Number of sessions, max. | 32 |
— Number of accessible variables, max. | 50 000 |
— Number of registerable nodes, max. | 10 000 |
— Number of subscriptions per session, max. | 20 |
— Sampling interval, min. | 100 ms |
— Publishing interval, min. | 500 ms |
— Number of server methods, max. | 20 |
— Number of inputs/outputs per server method, max. | 20 |
— Number of monitored items, max. | 1 000; for 1 s sampling interval and 1 s send interval |
— Number of server interfaces, max. | 10 of each “Server interfaces” / “Companion specification” type and 20 of the type “Reference namespace” |
— Number of nodes for user-defined server interfaces, max. | 1 000 |
● Alarms and Conditions | Yes |
— Number of program alarms | 100 |
— Number of alarms for system diagnostics | 50 |
Further protocols | |
● MODBUS | Yes; MODBUS TCP |
Isochronous mode | |
Equidistance | Yes |
S7 message functions | |
Number of login stations for message functions, max. | 32 |
Program alarms | Yes |
Number of configurable program messages, max. | 5 000; Program messages are generated by the “Program_Alarm” block, ProDiag or GRAPH |
Number of loadable program messages in RUN, max. | 2 500 |
Number of simultaneously active program alarms | |
● Number of program alarms | 600 |
● Number of alarms for system diagnostics | 100 |
● Number of alarms for motion technology objects | 80 |
Test commissioning functions | |
Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 5 engineering systems |
Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
Single step | No |
Number of breakpoints | 8 |
Status/control | |
● Status/control variable | Yes |
● Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
● Number of variables, max. | |
— of which status variables, max. | 200; per job |
— of which control variables, max. | 200; per job |
Forcing | |
● Forcing | Yes |
● Forcing, variables | Peripheral inputs/outputs |
● Number of variables, max. | 200 |
Diagnostic buffer | |
● present | Yes |
● Number of entries, max. | 1 000 |
— of which powerfail-proof | 500 |
Traces | |
● Number of configurable Traces | 4; Up to 512 KB of data per trace are possible |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
● RUN/STOP LED | Yes |
● ERROR LED | Yes |
● MAINT LED | Yes |
● STOP ACTIVE LED | Yes |
● Connection display LINK TX/RX | Yes |
Supported technology objects | |
Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
● Number of available Motion Control resources for technology objects | 800 |
● Required Motion Control resources | |
— per speed-controlled axis | 40 |
— per positioning axis | 80 |
— per synchronous axis | 160 |
— per external encoder | 80 |
— per output cam | 20 |
— per cam track | 160 |
— per probe | 40 |
● Positioning axis | |
— Number of positioning axes at motion control cycle of 4 ms (typical value) | 5 |
— Number of positioning axes at motion control cycle of 8 ms (typical value) | 10 |
Controller | |
● PID_Compact | Yes; Universal PID controller with integrated optimization |
● PID_3Step | Yes; PID controller with integrated optimization for valves |
● PID-Temp | Yes; PID controller with integrated optimization for temperature |
Counting and measuring | |
● High-speed counter | Yes |
Ambient conditions | |
Ambient temperature during operation | |
● horizontal installation, min. | -25 °C; No condensation |
● horizontal installation, max. | 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off |
● vertical installation, min. | -25 °C; No condensation |
● vertical installation, max. | 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off |
Ambient temperature during storage/transportation | |
● min. | -40 °C |
● max. | 70 °C |
Altitude during operation relating to sea level | |
● Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— GRAPH | Yes |
Know-how protection | |
● User program protection/password protection | Yes |
● Copy protection | Yes |
● Block protection | Yes |
Access protection | |
● protection of confidential configuration data | Yes |
● Password for display | Yes |
● Protection level: Write protection | Yes |
● Protection level: Read/write protection | Yes |
● Protection level: Complete protection | Yes |
programming / cycle time monitoring / header | |
● lower limit | adjustable minimum cycle time |
● upper limit | adjustable maximum cycle time |
Dimensions | |
Width | 35 mm |
Height | 147 mm |
Depth | 129 mm |
Weights | |
Weight, approx. | 405 g |
[/fusion_table]
Weight | 0.452 kg |
---|---|
Dimensions | 15.1 × 15.2 × 4.7 cm |