Article number |
6ES7334-0CE01-0AA0 |
6ES7334-0KE00-0AB0 |
|
SM334, 4AI, 2AO, non isolated |
SM334, 4AI/2AO, 0-10V f.PT100 |
Supply voltage |
|
|
Load voltage L+ |
|
|
● Rated value (DC) |
24 V |
24 V |
● Reverse polarity protection |
|
Yes |
Input current |
|
|
from supply and load voltage L+ (without load), max. |
110 mA |
80 mA |
from backplane bus 5 V DC, max. |
55 mA |
60 mA |
Power loss |
|
|
Power loss, typ. |
3 W |
2 W |
Analog inputs |
|
|
Number of analog inputs |
4 |
4 |
● For voltage measurement |
4 |
2 |
● For resistance measurement |
|
4 |
permissible input voltage for voltage input (destruction limit), max. |
20 V |
20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) |
permissible input current for current input (destruction limit), max. |
40 mA |
|
Constant measurement current for resistance-type transmitter, typ. |
|
490 µA; at PT100 (490 µA), at 10 kOhm (105 µa) |
Cycle time (all channels) max. |
5 ms |
85 ms |
Input ranges |
|
|
● Voltage |
Yes |
Yes |
● Current |
Yes |
No |
● Thermocouple |
No |
No |
● Resistance thermometer |
No |
Yes |
● Resistance |
No |
Yes |
Input ranges (rated values), voltages |
|
|
● 0 to +10 V |
Yes |
Yes |
— Input resistance (0 to 10 V) |
100 kΩ |
100 kΩ |
Input ranges (rated values), currents |
|
|
● 0 to 20 mA |
Yes |
|
— Input resistance (0 to 20 mA) |
50 Ω |
|
Input ranges (rated values), resistance thermometer |
|
|
● Pt 100 |
|
Yes; only climatic range |
Input ranges (rated values), resistors |
|
|
● 0 to 10000 ohms |
|
Yes |
Characteristic linearization |
|
|
● parameterizable |
|
Yes |
— for resistance thermometer |
|
Pt100 (climate) |
Cable length |
|
|
● shielded, max. |
200 m |
100 m |
Analog outputs |
|
|
Number of analog outputs |
2 |
2 |
Voltage output, short-circuit protection |
Yes |
Yes |
Voltage output, short-circuit current, max. |
11 mA |
30 mA |
Current output, no-load voltage, max. |
15 V |
|
Output ranges, voltage |
|
|
● 0 to 10 V |
Yes |
Yes |
Output ranges, current |
|
|
● 0 to 20 mA |
Yes |
|
Load impedance (in rated range of output) |
|
|
● with voltage outputs, min. |
5 kΩ |
2.5 kΩ |
● with voltage outputs, capacitive load, max. |
1 µF |
1 µF |
● with current outputs, max. |
300 Ω |
|
● with current outputs, inductive load, max. |
1 mH |
|
Cable length |
|
|
● shielded, max. |
200 m |
100 m |
Analog value generation for the inputs |
|
|
Integration and conversion time/resolution per channel |
|
|
● Resolution with overrange (bit including sign), max. |
8 bit |
12 bit |
● Integration time, parameterizable |
No |
Yes |
● Integration time (ms) |
|
16,67 / 20 ms |
● Interference voltage suppression for interference frequency f1 in Hz |
|
50 / 60 Hz |
Analog value generation for the outputs |
|
|
Integration and conversion time/resolution per channel |
|
|
● Resolution with overrange (bit including sign), max. |
8 bit |
12 bit |
● Conversion time (per channel) |
500 µs |
500 µs |
Settling time |
|
|
● for resistive load |
0.3 ms |
0.8 ms |
● for capacitive load |
3 ms |
0.8 ms |
● for inductive load |
0.3 ms |
|
Encoder |
|
|
Connection of signal encoders |
|
|
● for voltage measurement |
Yes |
Yes |
● for current measurement as 2-wire transducer |
No |
|
● for current measurement as 4-wire transducer |
Yes |
|
● for resistance measurement with two-wire connection |
|
Yes |
● for resistance measurement with three-wire connection |
|
Yes |
● for resistance measurement with four-wire connection |
|
Yes |
Errors/accuracies |
|
|
Operational error limit in overall temperature range |
|
|
● Voltage, relative to input range, (+/-) |
0.9 % |
0.7 %; 0 to 10V |
● Current, relative to input range, (+/-) |
0.8 % |
|
● Resistance, relative to input range, (+/-) |
|
3.5 %; 10 kOhm |
● Resistance thermometer, relative to input range, (+/-) |
|
1 % |
● Voltage, relative to output range, (+/-) |
0.6 % |
1 % |
● Current, relative to output range, (+/-) |
1 % |
|
Basic error limit (operational limit at 25 °C) |
|
|
● Voltage, relative to input range, (+/-) |
0.7 % |
0.5 %; 0 to 10V |
● Current, relative to input range, (+/-) |
0.6 % |
|
● Resistance, relative to input range, (+/-) |
|
2.8 %; 10 kOhm |
● Resistance thermometer, relative to input range, (+/-) |
|
0.8 % |
● Voltage, relative to output range, (+/-) |
0.5 % |
0.85 % |
● Current, relative to output range, (+/-) |
0.5 % |
|
Interrupts/diagnostics/status information |
|
|
Alarms |
No |
No |
Diagnostics function |
No |
No |
Potential separation |
|
|
Potential separation analog inputs |
|
|
● between the channels and backplane bus |
No |
Yes |
Potential separation analog outputs |
|
|
● between the channels |
No |
No |
● between the channels and backplane bus |
No |
Yes |
● between the channels and the power supply of the electronics |
Yes |
Yes |
Isolation |
|
|
Isolation tested with |
500 V DC |
500 V DC |
connection method / header |
|
|
required front connector |
20-pin |
20-pin |
Dimensions |
|
|
Width |
40 mm |
40 mm |
Height |
125 mm |
125 mm |
Depth |
117 mm |
117 mm |
Weights |
|
|
Weight, approx. |
285 g |
200 g |