Input |
|
Article number |
6EP3333-6SB00-0AY0 |
type of the power supply network |
1-phase AC or DC |
supply voltage at AC |
|
● minimum rated value |
100 V |
● maximum rated value |
240 V |
● initial value |
85 V |
● full-scale value |
264 V |
input voltage |
|
● at DC |
110 … 300 V |
design of input wide range input |
Yes |
overvoltage overload capability |
300 V AC for 1 s |
operating condition of the mains buffering |
at Vin = 187 V |
buffering time for rated value of the output current in the |
40 ms |
event of power failure minimum |
|
operating condition of the mains buffering |
at Vin = 187 V |
line frequency |
|
● 1 rated value |
50 Hz |
● 2 rated value |
60 Hz |
line frequency |
47 … 63 Hz |
input current |
|
● at rated input voltage 120 V |
1.95 A |
● at rated input voltage 230 V |
0.97 A |
current limitation of inrush current at 25 °C maximum |
31 A |
I2t value maximum |
2.5 A²·s |
fuse protection type |
internal |
● in the feeder |
Recommended miniature circuit breaker: from 10 A characteristic B or from 6 A characteristic C |
Output |
|
voltage curve at output |
Controlled, isolated DC voltage |
output voltage at DC rated value |
24 V |
output voltage |
|
● at output 1 at DC rated value |
24 V |
relative overall tolerance of the voltage |
3% |
relative control precision of the output voltage |
|
● on slow fluctuation of input voltage |
0.1% |
● on slow fluctuation of ohm loading |
0.1% |
residual ripple |
|
● maximum |
200 mV |
● typical |
30 mV |
voltage peak |
|
● maximum |
300 mV |
● typical |
50 mV |
adjustable output voltage |
22.2 … 26.4 V |
product function output voltage adjustable |
Yes |
type of output voltage setting |
via potentiometer |
display version for normal operation |
Green LED for output voltage OK |
behavior of the output voltage when switching on |
No overshoot of Vout (soft start) |
response delay maximum |
0.5 s |
voltage increase time of the output voltage |
|
● typical |
100 ms |
output current |
|
● rated value |
4 A |
● rated range |
0 … 4 A; +55 … +70 °C: Derating 2%/K |
supplied active power typical |
96 W |
product feature |
|
● bridging of equipment |
Yes |
number of parallel-switched equipment resources for |
2 |
increasing the power |
|
Efficiency |
89% |
efficiency in percent |
|
power loss [W] |
12 W |
● at rated output voltage for rated value of the output |
|
current typical |
0.3 W |
● during no-load operation maximum |
|
Closed-loop control |
0.2% |
relative control precision of the output voltage with rapid |
|
fluctuation of the input voltage by +/- 15% typical |
|
relative control precision of the output voltage at load step |
2% |
of resistive load 10/90/10 % typical |
|
setting time |
|
● load step 10 to 90% typical |
1 ms |
● load step 90 to 10% typical |
1 ms |
Protection and monitoring |
|
design of the overvoltage protection |
Yes, according to EN 60950-1 |
response value current limitation typical |
5 A |
property of the output short-circuit proof |
Yes |
design of short-circuit protection |
Constant current characteristic |
enduring short circuit current RMS value |
|
● maximum |
5 A |
overcurrent overload capability in normal operation |
overload capability 150% lout rated typ. 200 ms |
display version for overload and short circuit |
– |
measuring point for output current |
50 mV =^ 4 A |
overcurrent overload capability when switching on |
150% Iout rated typ. 200 ms |
Safety |
|
galvanic isolation between input and output |
Yes |
galvanic isolation |
Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
operating resource protection class |
Class II (without protective conductor) |
protection class IP |
IP20 |
Approvals |
|
certificate of suitability |
|
● CE marking |
Yes |
● UL approval |
Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273 |
● CSA approval |
Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273 |
● cCSAus, Class 1, Division 2 |
No |
● ATEX |
No |
certificate of suitability |
|
● IECEx |
No |
● NEC Class 2 |
No |
● ULhazloc approval |
No |
● FM registration |
No |
type of certification CB-certificate Y |
Yes |
certificate of suitability |
|
● EAC approval |
Yes |
certificate of suitability shipbuilding approval |
Yes |
shipbuilding approval |
ABS, BV, DNV GL, LRS |
Marine classification association |
|
● American Bureau of Shipping Europe Ltd. (ABS) |
Yes |
● French marine classification society (BV) |
Yes |
● DNV GL |
Yes |
● Lloyds Register of Shipping (LRS) |
Yes |
● Nippon Kaiji Kyokai (NK) |
No |
EMC |
|
standard |
|
● for emitted interference |
EN 55022 Class B |
● for mains harmonics limitation |
EN 61000-3-2 |
● for interference immunity |
EN 61000-6-2 |
environmental conditions |
|
ambient temperature |
|
● during operation |
-25 … +70 °C; with natural convection |
● during transport |
-40 … +85 °C |
● during storage |
-40 … +85 °C |
environmental category according to IEC 60721 |
Climate class 3K3, 5 … 95% no condensation |
Mechanics |
|
type of electrical connection |
screw-type terminals |
● at input |
L, N: 1 screw terminal each for 0.5 … 2.5 mm2 single-core/finely stranded |
● at output |
+, -: 1 screw terminal each for 0.5 … 2.5 mm² |
● for auxiliary contacts |
– |
width of the enclosure |
72 mm |
height of the enclosure |
90 mm |
depth of the enclosure |
53 mm |
required spacing |
|
● top |
20 mm |
● bottom |
20 mm |
● left |
0 mm |
● right |
0 mm |
net weight |
0.29 kg |
product feature of the enclosure housing can be lined up |
Yes |
fastening method |
Snaps onto DIN rail EN 60715 35×7.5/15, direct mounting in different mounting positions |
MTBF at 40 °C |
2 391 480 h |
other information |
Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
|
|