product brand name |
SIRIUS |
Article Number |
3RA2815-1FW10 |
product designation |
Solid-state time-delay auxiliary switch |
product type designation |
3RA28 |
General technical data |
|
size of contactor can be combined company-specific |
S00, S0, S2, S3 |
product component semi-conductor output |
No |
product extension required remote control |
No |
product extension optional remote control |
No |
insulation voltage for overvoltage category III according to |
300 V |
IEC 60664 with degree of pollution 3 rated value |
|
test voltage for isolation test |
1.5 kV |
degree of pollution |
3 |
surge voltage resistance rated value |
4 kV |
test voltage for surge voltage test |
4 800 V |
protection class IP of the terminal |
IP20 |
shock resistance according to IEC 60068-2-27 |
15g / 11 ms |
vibration resistance according to IEC 60068-2-6 |
10 … 59 Hz: 0.35 mm, 60 … 150 Hz: 2g |
mechanical service life (switching cycles) typical |
10 000 000 |
mechanical service life (switching cycles) |
|
● with contactor 3R.2 of frame size S00 |
10 000 000 |
● with contactor 3R.2 of frame size S0 |
10 000 000 |
● with contactor 3R.2 of frame size S2 |
10 000 000 |
● with contactor 3R.2 of frame size S3 |
10 000 000 |
electrical endurance (switching cycles) at AC-15 at 230 V typical |
100 000 |
electrical endurance (switching cycles) |
|
● with contactor 3R.2 of frame size S00 |
100 000 |
● with contactor 3R.2 of frame size S0 |
100 000 |
● with contactor 3R.2 of frame size S2 |
100 000 |
● with contactor 3R.2 of frame size S3 |
100 000 |
adjustable time |
0.05 … 100 s |
relative setting accuracy relating to full-scale value |
15% |
minimum ON period |
200 ms |
recovery time |
150 ms |
reference code according to IEC 81346-2 |
K |
relative repeat accuracy |
1% |
influence of the surrounding temperature |
±1 % |
power supply influence |
±1 % |
Substance Prohibitance (Date) |
10/1/2009 |
Product Function |
|
product function star-delta circuit |
No |
Control circuit/ Control |
|
type of voltage of the control supply voltage |
AC/DC |
control supply voltage 1 at AC |
|
● at 50 Hz |
24 … 240 V |
● at 60 Hz |
24 … 240 V |
control supply voltage frequency 1 |
50 … 60 Hz |
control supply voltage 1 |
|
● at DC |
24 … 240 V |
operating range factor control supply voltage rated |
|
value at DC |
|
● initial value |
0.85 |
● full-scale value |
1.1 |
operating range factor control supply voltage rated |
|
value at AC at 50 Hz |
|
● initial value |
0.85 |
● full-scale value |
1.1 |
operating range factor control supply voltage rated |
|
value at AC at 60 Hz |
|
● initial value |
0.85 |
● full-scale value |
1.1 |
design of the surge suppressor with |
with varistor |
Switching Function |
|
switching function |
|
● ON-delay |
No |
● ON-delay/instantaneous contact |
No |
● passing make contact |
No |
● passing make contact/instantaneous contact |
No |
● OFF delay |
Yes |
switching function |
|
● flashing symmetrically with interval start/instantaneous |
No |
● flashing symmetrically with interval start |
No |
● flashing symmetrically with pulse start/instantaneous |
No |
● flashing symmetrically with pulse start |
No |
● flashing asymmetrically with interval start |
No |
● flashing asymmetrically with pulse start switching function |
No |
switching function |
|
● constant clock cycle with pulse start |
No |
● constant clock cycle with interval start switching function |
No |
switching function |
|
● variably clocked with pulse start |
No |
● variably clocked with interval start switching function |
No |
switching function |
|
● star-delta circuit with delay time |
No |
● star-delta circuit |
No |
switching function with control signal |
|
● additive ON-delay |
No |
● passing break contact |
No |
● passing break contact/instantaneous |
No |
● OFF delay |
No |
● OFF delay/instantaneous |
No |
● pulse delayed |
No |
● pulse delayed/instantaneous |
No |
● pulse-shaping |
No |
● pulse-shaping/instantaneous |
No |
● additive ON-delay/instantaneous |
No |
● ON-delay/OFF-delay |
No |
● ON-delay/OFF-delay/instantaneous |
No |
● passing make contact |
No |
● passing make contact/instantaneous contact |
No |
switching function of interval relay with control signal |
|
● retrotriggerable with deactivated control signal/instantaneous contact |
No |
● retrotriggerable with switched-on control signal |
No |
● retrotriggerable with switched-on control |
No |
signal/instantaneous contact |
|
● retriggerable with deactivated control signal |
No |
design of the control terminal non-floating |
No |
Short-circuit protection |
|
design of the fuse link for short-circuit protection of the auxiliary switch required |
fuse gL/gG: 4 A |
Auxiliary circuit |
|
material of switching contacts |
AgNi |
number of NC contacts |
|
● delayed switching |
1 |
number of NO contacts |
|
● delayed switching |
1 |
operational current of auxiliary contacts at AC-15 |
|
● maximum |
3 A |
● at 24 V |
3 A |
● at 250 V |
3 A |
operational current of auxiliary contacts as NC contact at AC-15 |
|
● at 24 V |
3 A |
● at 250 V |
3 A |
operational current of auxiliary contacts as NO contact at AC-15 |
|
● at 24 V |
3 A |
● at 250 V |
3 A |
operational current of auxiliary contacts at DC-13 |
1 … 0.1 |
operational current of auxiliary contacts at DC-13 |
|
● at 24 V |
1 A |
● at 125 V |
0.2 A |
● at 250 V |
0.1 A |
operating frequency with 3RT2 contactor maximum |
2 500 1/h |
contact rating of auxiliary contacts according to UL |
B300 / R300 |
Main circuit |
|
type of voltage |
AC/DC |
Inputs/ Outputs |
|
product function |
|
● at the relay outputs switchover delayed/without |
No |
● non-volatile |
No |
Electromagnetic compatibility |
|
EMC immunity according to IEC 61812-1 |
Environment A (industrial area) |
conducted interference |
|
● due to burst according to IEC 61000-4-4 |
2 kV network connection / 1 kV control connection |
● due to conductor-earth surge according to IEC 61000-4-5 |
2 kV |
● due to conductor-conductor surge according to IEC 61000-4-5 |
1 kV |
field-based interference according to IEC 61000-4-3 |
10 V/m |
electrostatic discharge according to IEC 61000-4-2 |
8 kV |
Safety related data |
|
protection class IP on the front according to IEC 60529 |
IP20 |
type of insulation |
Basic insulation |
category according to EN 954-1 |
none |
Connections/ Terminals |
|
product component removable terminal for auxiliary |
Yes |
and control circuit |
|
type of electrical connection for auxiliary and control circuit |
screw-type terminals |
type of connectable conductor cross-sections |
|
● solid |
0.5 … 4 mm², 2x (0.5 … 2.5 mm²) |
● finely stranded with core end processing |
1x (0.5 … 2.5 mm²), 2x (0.5 … 1.5 mm²) |
● at AWG cables solid |
2x (20 … 14) |
● at AWG cables stranded |
2x (20 … 14) |
connectable conductor cross-section |
|
● solid |
0.5 … 4 mm² |
● finely stranded with core end processing |
0.5 … 2.5 mm² |
● finely stranded without core end processing |
0.25 … 1.5 mm² |
AWG number as coded connectable conductor cross |
|
section |
|
● solid |
20 … 14 |
● stranded |
20 … 14 |
Installation/ mounting/ dimensions |
|
mounting position |
any (like contactor) |
fastening method |
clip-on |
height |
38 mm |
width |
45 mm |
depth |
74 mm |
required spacing |
|
● with side-by-side mounting |
|
— forwards |
0 mm |
— backwards |
0 mm |
— upwards |
0 mm |
— downwards |
0 mm |
— at the side |
0 mm |
● for grounded parts |
|
— forwards |
0 mm |
— backwards |
0 mm |
— upwards |
0 mm |
— at the side |
0 mm |
— downwards |
0 mm |
● for live parts |
|
— forwards |
0 mm |
— backwards |
0 mm |
— upwards |
0 mm |
— downwards |
0 mm |
— at the side |
0 mm |
Ambient conditions |
|
installation altitude at height above sea level maximum |
2 000 m |
ambient temperature |
|
● during operation |
-25 … +60 °C |
● during storage |
-40 … +85 °C |
● during transport |
-40 … +85 °C |
relative humidity during operation |
0 … 95 % |