Article number |
6ES7223-0BD30-0XB0 |
6ES7223-3AD30-0XB0 |
6ES7223-3BD30-0XB0 |
|
Signal Board SB1223, 2 DI/2 DO |
Signal Board SB 1223, 2DI/2DQ 5V 200KHz |
Signal Board SB 1223, 2DI/2DQ 24V 200KHz |
General information |
|
|
|
Product type designation |
SB 1223, DI 2×24 V DC/DQ 2×24 V DC |
SB 1223, DI 2×5 V DC/DQ 2×5 V DC 200 kHz |
SB 1223, DI 2×24 V DC/DQ 2×24 V DC 200 kHz |
Supply voltage |
|
|
|
permissible range, lower limit (DC) |
20.4 V |
|
|
permissible range, upper limit (DC) |
28.8 V |
|
|
Input current |
|
|
|
from backplane bus 5 V DC, typ. |
50 mA |
35 mA |
35 mA |
output voltage / header |
|
|
|
supply voltage of the transmitters / header |
|
|
|
● supply current / from supply voltage for transmitter / maximum |
4 mA; per channel |
|
|
Power loss |
|
|
|
Power loss, typ. |
1 W |
0.5 W |
0.5 W |
Digital inputs |
|
|
|
Number of digital inputs |
2; Current-sinking |
2; Current-sourcing |
2; Current-sourcing |
● in groups of |
1 |
2 |
2 |
Input characteristic curve in accordance with IEC 61131, type 1 |
Yes |
|
|
Number of simultaneously controllable inputs |
|
|
|
all mounting positions |
|
|
|
— up to 40 °C, max. |
2 |
|
2 |
Input voltage |
|
|
|
● Type of input voltage |
DC |
DC |
DC |
● Rated value (DC) |
24 V |
5 V |
24 V |
● for signal “0” |
0 to 5 V |
(L+ minus 1.0 V DC) … L+ |
(L+ minus 5.0 V DC) … L+ |
● for signal “1” |
+15 to +30 V |
0 V … (L+ minus 2.0 V DC) |
0 V … (L+ minus 10 V DC) |
Input current |
|
|
|
● for signal “0”, max. (permissible quiescent current) |
1 mA |
2.2 mA |
1.4 mA |
● for signal “1”, min. |
|
5.1 mA |
2.9 mA |
● for signal “1”, typ. |
7 mA |
15 mA |
7 mA |
Input delay (for rated value of input voltage) |
|
|
|
for standard inputs |
|
|
|
— parameterizable |
Yes; 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four |
Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms |
Yes; 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 μs; 0.05 / 0.1 / 0.2 / 0.4 / 0.8 / 1.6 / 3.2 / 6.4 / 10.0 / 12.8 / 20.0 ms |
— at “0” to “1”, max. |
2 µs |
|
|
— at “1” to “0”, max. |
10 µs |
|
|
for interrupt inputs |
|
|
|
— parameterizable |
Yes |
Yes |
Yes |
for technological functions |
|
|
|
— parameterizable |
Yes |
Yes |
Yes |
Cable length |
|
|
|
● shielded, max. |
50 m |
50 m; shielded, twisted pair |
50 m; shielded, twisted pair |
Digital outputs |
|
|
|
Number of digital outputs |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
2; MOSFET, solid-state (current-sinking/current-sourcing) |
● in groups of |
1 |
2 |
2 |
Short-circuit protection |
No |
No |
No |
Switching capacity of the outputs |
|
|
|
● with resistive load, max. |
0.5 A |
0.1 A |
0.1 A |
● on lamp load, max. |
5 W |
|
|
Load resistance range |
|
|
|
● upper limit |
0.6 Ω |
7 Ω |
|
Output voltage |
|
|
|
● Rated value (DC) |
24 V |
5 V |
24 V |
● for signal “0”, max. |
0.1 V; with 10 kOhm load |
0.2 V |
1 V |
● for signal “1”, min. |
20 V |
L+ minus 0.7 V DC |
L+ (-1.5 V) |
● for signal “1”, max. |
|
6 V |
|
Output current |
|
|
|
● for signal “1” permissible range, max. |
0.5 A |
0.1 A |
0.1 A |
● for signal “0” residual current, max. |
10 µA |
|
|
Cable length |
|
|
|
● shielded, max. |
50 m |
50 m |
50 m |
Interrupts/diagnostics/status information |
|
|
|
Alarms |
Yes |
|
|
Diagnostics function |
Yes |
|
|
Diagnostics indication LED |
|
|
|
● for status of the inputs |
Yes |
Yes |
Yes |
● for status of the outputs |
Yes |
Yes |
Yes |
Standards, approvals, certificates |
|
|
|
CE mark |
Yes |
Yes |
Yes |
CSA approval |
Yes |
Yes |
Yes |
UL approval |
Yes |
Yes |
Yes |
cULus |
Yes |
Yes |
Yes |
FM approval |
Yes |
Yes |
Yes |
RCM (formerly C-TICK) |
Yes |
Yes |
Yes |
KC approval |
Yes |
Yes |
Yes |
Marine approval |
Yes |
Yes |
Yes |
Ambient conditions |
|
|
|
Free fall |
|
|
|
● Fall height, max. |
0.3 m; five times, in product package |
0.3 m; five times, in product package |
0.3 m; five times, in product package |
Ambient temperature during operation |
|
|
|
● min. |
-20 °C |
-20 °C |
-20 °C |
● max. |
60 °C |
60 °C |
60 °C |
● horizontal installation, min. |
-20 °C |
-20 °C |
-20 °C |
● horizontal installation, max. |
60 °C |
60 °C |
60 °C |
● vertical installation, min. |
-20 °C |
-20 °C |
-20 °C |
● vertical installation, max. |
50 °C |
50 °C |
50 °C |
Ambient temperature during storage/transportation |
|
|
|
● min. |
-40 °C |
-40 °C |
-40 °C |
● max. |
70 °C |
70 °C |
70 °C |
Air pressure acc. to IEC 60068-2-13 |
|
|
|
● Storage/transport, min. |
660 hPa |
660 hPa |
660 hPa |
● Storage/transport, max. |
1 080 hPa |
1 080 hPa |
1 080 hPa |
Relative humidity |
|
|
|
● Operation at 25 ℃ without condensation, max. |
95 % |
95 % |
95 % |
Mechanics/material |
|
|
|
Enclosure material (front) |
|
|
|
● Plastic |
Yes |
Yes |
Yes |
Dimensions |
|
|
|
Width |
38 mm |
38 mm |
38 mm |
Height |
62 mm |
62 mm |
62 mm |
Depth |
21 mm |
21 mm |
21 mm |
Weights |
|
|
|
Weight, approx. |
40 g |
35 g |
35 g |