Part Number |
TM4ES4 |
product or component type |
Ethernet unmanaged switch |
Complementary |
range compatibility |
Modicon M251 |
Modicon M241 |
product compatibility |
Modicon M241 logic controller |
Modicon M251 logic controller |
current consumption |
360 mA at 5 V DC for communication bus |
integrated connection type |
Ethernet: 4 RJ45 connector |
transmission rate |
10/100 Mbit/s |
port Ethernet |
10BASE-T/100BASE-TX – 4 port(s) copper cable |
web services |
Web server |
communication service |
Modbus TCP server |
Modbus TCP slave device |
FTP |
NGVL |
Monitoring |
IEC VAR ACCESS |
Programming |
SNMP |
Modbus TCP client |
Downloading |
Updating firmware |
Ethernet/IP slave device |
DHCP client |
maximum number of connections |
8 Modbus server |
16 Ethernet/IP device |
communication port protocol |
Ethernet IP/Modbus TCP |
TCP (Transmission Control Protocol) |
UDP (User Datagram Protocol) |
SNMP |
redundancy |
No |
local signalling |
1 LED (green) for PWR |
1 LED per channel (green/yellow) for Ethernet link |
1 LED per channel (green) for Ethernet port activity |
electrical connection |
RJ45 4 connectors for connecting Ethernet network |
Screw connector terminal for connecting the functional ground |
Marking |
CE |
surge withstand |
1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 |
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5 |
2 kV relay output common mode conforming to EN/IEC 61000-4-5 |
1 kV I/O common mode conforming to EN/IEC 61000-4-5 |
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 |
0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 |
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5 |
1 kV relay output differential mode conforming to EN/IEC 61000-4-5 |
0.5 kV I/O differential mode conforming to EN/IEC 61000-4-5 |
mounting support |
Top hat type TH35-15 rail conforming to IEC 60715 |
Top hat type TH35-7.5 rail conforming to IEC 60715 |
plate or panel with fixing kit |
width |
25 mm |
Height |
90 mm |
Depth |
90 mm |
Net weight |
0.125 kg |
Environment |
Standards |
UL 508 |
EN/IEC 61131-2 |
product certifications |
CULus |
C-Tick |
resistance to electrostatic discharge |
8 kV in air conforming to EN/IEC 61000-4-2 |
4 kV on contact conforming to EN/IEC 61000-4-2 |
8 kV in air conforming to Marine specification (LR, ABS, DNV, GL) |
6 kV on contact conforming to Marine specification (LR, ABS, DNV, GL) |
resistance to electromagnetic fields |
10 V/m 80 MHz…1 GHz conforming to EN/IEC 61000-4-3 |
3 V/m 1.4 GHz…2 GHz conforming to EN/IEC 61000-4-3 |
1 V/m 2…2.7 GHz conforming to EN/IEC 61000-4-3 |
resistance to fast transients |
2 kV (power lines) conforming to EN/IEC 61000-4-4 |
2 kV (relay output) conforming to EN/IEC 61000-4-4 |
1.5 kV (I/O) conforming to EN/IEC 61000-4-4 |
1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 |
1 kV (serial link) conforming to EN/IEC 61000-4-4 |
resistance to conducted disturbances |
10 V 0.15…80 MHz conforming to EN/IEC 61000-4-6 |
3 V 0.1…80 MHz conforming to Marine specification (LR, ABS, DNV, GL) |
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL) |
electromagnetic emission |
Conducted emissions – test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011 |
Conducted emissions – test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011 |
Conducted emissions – test level: 120…69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 |
Conducted emissions – test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 |
Radiated emissions – test level: 40 dBμV/m QP class A at 30…230 MHz conforming to EN/IEC 55011 |
Radiated emissions – test level: 60…54 dBμV/m QP at 30…100 MHz conforming to Marine specification (LR, ABS, DNV, GL) |
Radiated emissions – test level: 24 dBμV/m QP at 156…165 MHz conforming to Marine specification (LR, ABS, DNV, GL) |
Conducted emissions – test level: 79…63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 |
Radiated emissions – test level: 47 dBμV/m QP class A at 230…1000 MHz conforming to EN/IEC 55011 |
Radiated emissions – test level: 80…50 dμV/m QP at 150…30000 kHz conforming to Marine specification (LR, ABS, DNV, GL) |
Radiated emissions – test level: 54 dBμV/m QP at 100…2000 MHz conforming to Marine specification (LR, ABS, DNV, GL) |
ambient air temperature for operation |
-10…55 °C horizontal installation |
-10…50 °C vertical installation |
Ambient air temperature for storage |
-25…70 °C |
relative humidity |
10…95 %, without condensation (in operation) |
10…95 %, without condensation (in storage) |
IP degree of protection |
IP20 with protective cover in place |
pollution degree |
2 |
Operating altitude |
0…2000 m |
Storage altitude |
0…3000 m |
vibration resistance |
1 mm at 5…13.2 Hz on symmetrical rail |
3 gn at 8.7…150 Hz on symmetrical rail |
1 mm at 5…13.2 Hz on panel mounting |
0.7 gn at 13.2…100 Hz on panel mounting |
shock resistance |
15 gn for 11 ms |
Packing Units |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
5.635 cm |
Package 1 Width |
11.532 cm |
Package 1 Length |
17.033 cm |
Package 1 Weight |
210.0 g |
Unit Type of Package 2 |
S03 |
Number of Units in Package 2 |
20 |
Package 2 Height |
30.0 cm |
Package 2 Width |
30.0 cm |
Package 2 Length |
40.0 cm |
Package 2 Weight |
5.04 k+B+A1:B112 |