Size |
M8 |
M12 |
Type |
Shielded |
Non-shielded |
Shielded |
Non-shielded |
E2A-M08[]S02-M1-B1/B2/C1/C2
E2A-S08[]S02-[][]-B1/B2/C1/C2 |
E2A-M08[]N04-M1-B1/B2/C1/C2
E2A-S08[]N04-[][]-B1/B2/C1/C2 |
E2A-M12[]S04-[][]-B1/B2/C1/C2 |
E2A-M12[]N08-[][]-B1/B2/C1/C2 |
Sensing distance |
2 mm ± 10% |
4 mm ± 10% |
4 mm ± 10% |
8 mm ± 10% |
Setting distance |
0 to 1.6 mm |
0 to 3.2 mm |
0 to 3.2 mm |
0 to 6.4 mm |
Differential travel |
10% max. of sensing distance |
Target |
Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
Standard target
(mild steel ST37) |
8×8×1 mm |
12×12×1 mm |
12×12×1 mm |
24×24×1 mm |
Response frequency
*1 |
1,500 Hz |
1,000 Hz |
1,000 Hz |
800 Hz |
Power supply voltage
(operating voltage range) |
12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) |
Current consumption
(DC 3-wire) |
10 mA max. |
Output type |
-B models: PNP open collector
-C models: NPN open collector |
Control
output |
Load
current
*2 |
200 mA max. (32 VDC max.) |
Residual
voltage |
2 V max. (under load current of 200 mA with cable length of 2 m) |
Indicator |
Operation indicator (Yellow LED) |
Operation mode
(with sensing object
approaching) |
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to Data Sheet. |
Protection circuit |
Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection |
Ambient air
temperature |
Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation) |
Temperature influence
*2 |
±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C |
Ambient humidity |
Operating: 35% to 95%, Storage: 35% to 95% |
Voltage influence |
±1% max. of sensing distance in rated voltage range ±15% |
Insulation resistance |
50 MΩ min. (at 500 VDC) between current carry parts and case |
Dielectric strength |
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case |
Vibration resistance |
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions |
Shock resistance |
500 m/s2, 10 times each in X, Y and Z directions |
1,000 m/s2, 10 times each in X, Y and Z directions |
Standard and listings
*3 |
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC |
Connection method |
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models |
Weight
(packa-
ged) |
Pre-wired
model |
Approx. 65 g |
Approx. 85 g |
M12
connector
model |
M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g |
Approx. 35 g |
Material |
Case |
Stainless steel or brass-nickel plated |
Brass-nickel plated |
Sensing
surface |
PBT |
Cable |
PVC |
Clamping
nut |
Brass-nickel plated |