Main |
Part Number |
RE48ATM12MW |
Product Series |
Harmony Timer Relays |
product type |
Single function relay |
Electrical connections |
Plug-in terminal base 8-pin |
Solid state output type |
Relay |
Contact type and composition |
2 OC timing contacts, AgNi (cadmium free) |
component name |
RE48 |
delay type |
Power on-delay |
Delay range |
5…300 h |
2…120 min |
0.5…30 h |
0.2…12 h |
0.2…12 min |
0.2…12 s |
0.5…30 min |
2…120 h |
2. ..120 s |
0.02…1.2 s |
0.5…30 s |
5…300 s |
0.05…3 s |
5…300 min |
Rated supply voltage [Us] |
24…240 V AC/DC 50/60 Hz |
voltage range |
19…30 V AC |
0.9…1.2 Us DC |
Rated current [In] |
5A |
Additional information |
Product front panel size |
48x48mm |
control type |
Select switch cover |
covering material |
Flame retardant |
Repeatability |
+/- 0.2 % of maximum setting according to IEC 61812-1 |
temperature drift |
+/- 0.02 %/°C max. setting according to IEC 61812-1 |
voltage deviation |
+/- 0.2 %/V max. setting at 48…240 V |
+/- 1 %/V max. setting at 24…48 V |
Latency Accuracy Settings |
+/- 5 % of full scale at 25 °C conforming to IEC 61812-1 |
Minimum pulse duration |
20ms |
reset time |
25 ms discharge |
acceleration time |
55ms |
load factor |
100% |
Power consumption VA |
1.1 VA at 24 V |
4.8 VA at 240 V |
power consumption[W] |
0.5 W at 24 V |
1.7 W at 240 V |
Breaking capacity |
1250VA |
Minimum switching current |
100 mA |
Maximum switching current |
5A |
Maximum Switching Voltage |
250 VAC/DC |
Electrical life |
100000 times |
Mechanical life |
30000000 times |
The output voltage |
240 V at 5 A AC-12 |
30 V at 2 A DC-13 |
240 V at 1.5 A AC-15 |
logo |
CE |
surge withstand |
1 kV differential mode according to IEC 61000-4-5 level 3 |
2 kV common mode according to IEC 61000-4-5 level 3 |
installation method |
Panel Mounted: System Supplied with Product |
Base Mounting: Slot |
local signal indication |
1 LED (yellow) output relay status: |
LED indicator (green) flashing: relay energized timing in progress: |
LED indicator (green) steady: relay energized, not timing: |
Product Weight |
0.14kg |
environment |
Humidity Deviation |
+/- 0.05 %/%RH Maximum setting according to IEC 61812-1 |
Anti-instantaneous power failure |
10ms |
Insulation properties |
1 kV 1 mA/1 minute conforming to IEC 61812-1 |
Protect yourself from electric shock |
4 kV Class III according to IEC 60664-1 |
4 kV Class III according to IEC 61812-1 |
Standards compliant |
73/23/EEC |
93/68/EEC |
EN 50082-1/2 |
89/336/EEC |
EN 50081-1/2 |
IEC 61812-1 |
IEC 60669-2-3 |
certified product |
UL |
cULus |
C-Tick |
CSA |
storage environment temperature |
-40…70°C |
operating temperature |
-20…50°C |
IP protection class |
IP40 conforming to IEC 60529 (housing) |
IP50 conforming to IEC 60529 (front panel) |
Anti-vibration |
0.35 mm (f= 10…55 Hz) conforming to IEC 60068-2-6 |
Relative humidity |
93 % non-condensing according to IEC 60068-2-3 |
Anti-static discharge |
6 kV contact conforming to EN/IEC 61000-4-2 level 3 |
8 kV in air conforming to EN/IEC 61000-4-2 level 3 |
Anti-electromagnetic field |
10 V/m 26 MHz to 1 GHz conforming to IEC 61000-4-3 level 3 |
Anti-instantaneous pulse capability |
2 kV conforming to EN/IEC 61000-4-4 class 4 (capacitive connection clamp) |
4 kV conforming to EN/IEC 61000-4-4 class 4 (direct connection) |
Anti-radiation electromagnetic interference performance |
10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 level 3 |
Anti-interference voltage |
30 % / 10 ms according to EN/IEC 61000-4-11 |
60 % / 100 ms according to EN/IEC 61000-4-11 |
95 % / 5 s according to EN/IEC 61000-4-11 |
Radiated/conducted interference |
Class B 0.15…30 MHz conforming to EN 55022 (EN 55011 group 1) |
packaging unit |
Unit Type of Package 1 |
PCE |
Number of Units in Package 1 |
1 |
Package 1 Height |
5.7cm |
Package 1 Width |
10.5cm |
Package 1 Length |
6.2 cm |
Package 1 Weight |
126g |
Unit Type of Package 2 |
S02 |
Number of Units in Package 2 |
30 |
Package 2 Height |
15cm |
Package 2 Width |
30cm |
Package 2 Length |
40cm |
Package 2 Weight |
4.252kg |
contract warranty |
Warranty |
18 months |