Part Number: 6025057
Electro-mechanical safety switches: i12-SA113
OEM Spec Ref
| Number of positive action N/C contacts | 1 | 
| Number of N/O contacts | 1 | 
| Retaining force | ≤ 6 N | 
| Actuation frequency | ≤ 7,200 /h | 
| Actuation directions | 5 | 
| Approach speed | ≤ 10 m/min | 
| B10d parameter | 2 x 106 switching cycles (with small load) | 
| Type | Type 2 (EN ISO 14119) | 
| Actuator coding level | Low coding level (EN ISO 14119) | 
| Safe state in the event of a fault | The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit. | 
| Safe series connection | None, only individual wiring (with diagnostics) | 
| Connection type | Cable gland, 1 x M16 | 
| Conductor cross-section | ≤ 1.5 mm² | 
| Switching principle | Slow action switching element | 
| Usage category | AC-15/DC-13 (IEC 60947-5-1) | 
| Rated operating current (voltage) | 3 A (240 V AC) 2 A (24 V DC) | 
| Rated insulation voltage Ui | 240 V | 
| Rated impulse withstand voltage Uimp | 2,500 V AC | 
| Short-circuit protection | T10/10A | 
| Switching voltage | ≥ 5 V DC | 
| Switching current (switching voltage) | ≥ 5 mA (5 V DC) | 
| Weight | 0.08 kg | 
| Housing material | Glass-fiber reinforced thermoplastic | 
| Mechanical life | 1 x 106 switching cycles | 
| Enclosure rating | IP67 (IEC 60529) | 
| Ambient operating temperature | –20 °C … +80 °C | 
| Storage temperature | –20 °C … +80 °C | 
| Weight | 0.111 kg | 
|---|---|
| Dimensions | 10 × 4 × 13 cm |