Part Number: 6025057
Electro-mechanical safety switches: i12-SA113
OEM Spec Ref

Features

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Number of positive action N/C contacts 1
Number of N/O contacts 1
Retaining force ≤ 6 N
Actuation frequency ≤ 7,200 /h
Actuation directions 5
Approach speed ≤ 10 m/min

[/fusion_table]

 

Safety-related parameters

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

B10d parameter 2 x 106 switching cycles (with small load)
Type Type 2 (EN ISO 14119)
Actuator coding level Low coding level (EN ISO 14119)
Safe state in the event of a fault The switch has no internal fault detection and is unable to assume a safe state in the event of a fault. Fault detection is performed by the connected safety-related logic unit.

[/fusion_table]

 

Functions

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Safe series connection None, only individual wiring (with diagnostics)

[/fusion_table]

 

Interfaces

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Connection type Cable gland, 1 x M16
Conductor cross-section ≤ 1.5 mm²

[/fusion_table]

 

Electrical data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Switching principle Slow action switching element
Usage category AC-15/DC-13 (IEC 60947-5-1)
Rated operating current (voltage) 3 A (240 V AC)

2 A (24 V DC)

Rated insulation voltage Ui 240 V
Rated impulse withstand voltage Uimp 2,500 V AC
Short-circuit protection T10/10A
Switching voltage ≥ 5 V DC
Switching current (switching voltage) ≥ 5 mA (5 V DC)

[/fusion_table]

 

Mechanical data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Weight 0.08 kg
Housing material Glass-fiber reinforced thermoplastic
Mechanical life 1 x 106 switching cycles

[/fusion_table]

 

Ambient data

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Enclosure rating IP67 (IEC 60529)
Ambient operating temperature –20 °C … +80 °C
Storage temperature –20 °C … +80 °C

[/fusion_table]

 

Weight 0.111 kg