| General specifications | 
| Switching function | 
Normally open (NO) | 
| Output type | 
PNP | 
| Rated operating distance | 
40 mm | 
| Installation | 
non-flush | 
| Output polarity | 
DC | 
| Assured operating distance | 
0 … 32.4 mm | 
| Actual operating distance | 
36 … 44 mm | 
| Reduction factor rAl | 
0.33 | 
| Reduction factor rCu | 
0.31 | 
| Reduction factor r304 | 
0.74 | 
| Reduction factor rBrass | 
0.38 | 
| Output type | 
3-wire | 
| Nominal ratings | 
| Operating voltage | 
10 … 30 V DC | 
| Switching frequency | 
0 … 180 Hz | 
| Hysteresis | 
typ. 5 % | 
| Reverse polarity protection | 
reverse polarity protected | 
| Short-circuit protection | 
pulsing | 
| Voltage drop | 
≤ 2 V | 
| Operating current | 
0 … 200 mA | 
| Off-state current | 
0 … 0.5 mA | 
| No-load supply current | 
≤ 20 mA | 
| Time delay before availability | 
80 ms | 
| Operating voltage indicator | 
LED, green | 
| Switching state indicator | 
LED, yellow | 
| Functional safety related parameters | 
| MTTFd | 
1510 a | 
| Mission Time (TM) | 
20 a | 
| Diagnostic Coverage (DC) | 
0 % | 
| Compliance with standards and directives | 
| Standard conformity | 
 | 
 | 
Standards | 
EN 60947-5-2:2007 
EN 60947-5-2/A1:2012 
IEC 60947-5-2:2007 
IEC 60947-5-2 AMD 1:2012 | 
| Approvals and certificates | 
| Protection class | 
II | 
 | 
Rated insulation voltage | 
253 V | 
 | 
Rated impulse withstand voltage | 
4000 V | 
| UL approval | 
cULus Listed, General Purpose | 
| CCC approval | 
CCC approval / marking not required for products rated ≤36 V | 
| Ambient conditions | 
| Ambient temperature | 
-25 … 85 °C (-13 … 185 °F) | 
| Storage temperature | 
-40 … 85 °C (-40 … 185 °F) | 
| Mechanical specifications | 
| Connection type | 
Connector plug M12 x 1 , 4-pin | 
| Housing material | 
PA | 
| Sensing face | 
PA | 
| Degree of protection | 
IP68 / IP69K | 
| Cable | 
 | 
 | 
Cable diameter | 
3.3 mm ± 0.15 mm | 
| Mass | 
130 g |