Main |
Part Number |
ZCKJ2C |
ZCKJ1D |
ZCKJ1H7 |
ZCKJ1H29C |
Range of product |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Telemecanique Limit switches XC Standard |
Series name |
Standard format |
Standard type |
Standard type |
Standard type |
Product or component type |
Limit switch body |
Limit switch body |
Limit switch body |
Limit switch body |
device short name |
ZCKJ |
ZCKJ |
ZCKJ |
ZCKJ |
body type |
Fixed |
Fixed |
Fixed |
Fixed |
Product compatibility |
XCKJ |
XCK |
XCK |
XCK |
Associated head |
ZCKE629 |
ZCKE08 |
ZCKE619 |
ZCKE619 |
|
ZCKE63 |
ZCKE65 |
ZCKE64 |
ZCKE63 |
|
ZCKE23 |
ZCKE63 |
ZCKE66 |
ZCKE64 |
|
ZCKE64 |
ZCKE619 |
ZCKE67 |
ZCKE629 |
|
ZCKE06 |
ZCKE61 |
ZCKE63 |
ZCKE08 |
|
ZCKE05 |
ZCKE06 |
ZCKE62 |
ZCKE61 |
|
ZCKE08 |
ZCKE05 |
ZCKE23 |
ZCKE06 |
|
ZCKE67 |
ZCKE64 |
ZCKE05 |
ZCKE65 |
|
ZCKE21 |
ZCKE23 |
ZCKE629 |
ZCKE66 |
|
ZCKE619 |
ZCKE67 |
ZCKE08 |
ZCKE05 |
|
ZCKE65 |
ZCKE66 |
ZCKE21 |
ZCKE23 |
|
ZCKE62 |
ZCKE21 |
ZCKE61 |
ZCKE67 |
|
ZCKE66 |
ZCKE629 |
ZCKE06 |
ZCKE21 |
|
ZCKE61 |
ZCKE62 |
ZCKE65 |
ZCKE62 |
Body material |
Metal |
Metal |
Metal |
Metal |
Cable entry |
1 entry tapped for Pg 13.5 cable gland |
|
One entry hole for 1/2” NPT conduit |
1 for M20x1.6 cable gland |
Number of poles |
2 |
2 |
2 |
2 |
Contacts type and composition |
2 C/O |
1 NC + 1 NO |
1 NC + 1 NO |
1 NC + 1 NO |
Contact operation |
Snap action |
Momentary |
Momentary |
Momentary |
Number of steps |
1 1 position |
1 1 position |
1 1 position |
1 1 position |
Contacts material |
Silver plated contacts |
Silver plated contacts |
Silver plated contacts |
Silver plated contacts |
Complementary |
local display |
Without |
None |
None |
None |
Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.75…2 x 1.5 mm² |
Male connector M12, 5-pin |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Screw clamp terminal, clamping capacity: 1 x 0.34…2 x 1.5 mm² |
Positive opening |
Without |
Have |
Have |
Have |
Minimum actuation speed |
0.01 m/min |
0.01 m/min |
0.01 m/min |
0.01 m/min |
[Ie] rated operational current |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A |
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 Appendix A |
|
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A |
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A |
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A |
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 Appendix A |
[Ithe] conventional enclosed thermal current |
10:00 AM |
10A |
10A |
10A |
[Ui] rated insulation voltage |
500 V (pollution degree 3) conforming to IEC 60947-1 for contact block |
60 V (pollution degree 3) conforming to IEC 60947-1 for contact modules |
500 V (pollution degree 3) conforming to IEC 60947-1 for contact block |
500 V (pollution degree 3) conforming to IEC 60947-1 for contact block |
|
300 V conforming to CSA C22.2 No 14 for contact block |
|
300 V conforming to CSA C22.2 No 14 for contact block |
300 V conforming to CSA C22.2 No 14 for contact block |
|
300 V conforming to UL 508 for contact block |
|
300 V conforming to UL 508 for contact block |
300 V conforming to UL 508 for contact block |
Maximum resistance across terminals |
0.25 mOhm conforming to IEC 60255-7 category 3 |
0.25 mΩ conforming to IEC 60255-7 Safety Class 3 |
0.25 mΩ conforming to IEC 60255-7 Safety Class 3 |
0.25 mΩ conforming to IEC 60255-7 Safety Class 3 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 |
6 kV according to IEC 60664 |
6 kV according to IEC 60664 |
6 kV according to IEC 60664 |
|
6 kV conforming to IEC 60947-1 |
6 kV according to IEC 60947-1 |
6 kV according to IEC 60947-1 |
6 kV according to IEC 60947-1 |
Short-circuit protection |
10 A cartridge fuse, type gG |
10 A fuse fuse, type gG |
10 A fuse fuse, type gG |
10 A fuse fuse, type gG |
Electrical durability |
5000000 cycles, DC-13 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 |
5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 |
5000000 cycles, DC-13 120 V, 4 W, operating rating<60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C 5000000 cycles, DC-13 |
|
5000000 cycles, DC-13 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C |
24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C |
24 V, 10 W, operating rating< 60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Annex C |
|
5000000 cycles, DC-13 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C |
5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C |
5000000 cycles, DC-13 48 V, 7 W, operating rating <60 cycles/min, duty factor: 0.5 conforming to IEC 60947-5-1 Appendix C |
Width |
40 mm |
43 mm |
43 mm |
43 mm |
Height |
77 mm |
84mm |
84mm |
84mm |
Depth |
44 mm |
36mm |
36mm |
36mm |
Product weight |
0.31 kg |
0.3 kg |
0.3 kg |
0.3 kg |
Terminals description ISO n°1 |
(21-22)NC |
(23-24)NO |
(23-24)NO |
(23-24)NO |
|
(11-12)NC |
(11-12)NC |
(13-14)NO |
(11-12)NC |
|
(13-14)NO |
(13-14)NO |
(11-12)NC |
(13-14)NO |
|
(23-24)NO |
(21-22)NC |
(21-22)NC |
(21-22)NC |
Environment |
IP degree of protection |
IP66 |
IP66 |
IP66 |
IP66 |
IK degree of protection |
IK07 |
IK07 |
IK07 |
IK07 |
Ambient air temperature for operation |
10…120 °C for high temperature |
10…120 °C for high temperatures |
10…120 °C for high temperatures |
10…120 °C for high temperatures |
Ambient air temperature for storage |
10…120 °C |
10…120°C |
10…120°C |
10…120°C |
Environmental characteristic |
High temperature |
High temperature |
High temperature |
High temperature |
Packing Units |
Unit Type of Package 1 |
PCE |
PCE |
PCE |
PCE |
Number of Units in Package 1 |
1 |
1 |
1 |
1 |
Package 1 Height |
|
4.200 cm |
4.2 cm |
4.1 cm |
Package 1 Width |
|
7.000 cm |
4.6cm |
4.6cm |
Package 1 Length |
|
12.600 cm |
8.7cm |
8.8cm |
Package 1 Weight |
|
311.000g |
287.0g |
290.0g |
Unit Type of Package 2 |
|
S02 |
S02 |
PAL |
Number of Units in Package 2 |
|
18 |
Twenty four |
1152 |
Package 2 Height |
|
15.000 cm |
15.0cm |
75.0cm |
Package 2 Width |
|
30.000 cm |
30.0cm |
60.0cm |
Package 2 Length |
|
40.000 cm |
40.0cm |
80.0cm |
Package 2 Weight |
|
6.146 kg |
7.4kg |
358.272kg |
|
|
|
|
CAR |
|
|
|
|
18 |
|
|
|
|
14.6 cm |
|
|
|
|
16.0cm |
|
|
|
|
20.2 cm |
|
|
|
|
5.22kg |
Contractual warranty |
Warranty |
|
18 months |
18 months |
18 months |