Contact Us:
sales@inosaki.com

BTF13-P1BM1025 – SICK Wire Draw Encoders

$ 2,927.90

SKU SICK 1060991 Category

Part Number: 1060991
Encoders Model: BTF13-P1BM1025
OEM Spec Ref 

 

Performance

Measurement range 0 m … 10 m
Encoder Absolute encoders
Resolution (wire draw + encoder) 0.04 mm 1) 2)
Repeatability ≤ 1.5 mm 3)
Linearity ≤ ± 2 mm 3)
Hysteresis ≤ 3 mm 3)

1) The values shown have been rounded.

2) Example calculation based on the BTF08 with PROFINET: 200 mm (wire draw length per revolution – see Mechanical data): 262,144 (number of steps per revolution) = 0.001 mm (resolution of wire draw + encoder combination).

3) Value applies to wire draw mechanism.

 

Interfaces

Communication interface PROFIBUS DP
Programmable/configurable

 

Electrical Data

Connection type Male connector, Female connector, 2x, 1x, M12, M12, 5-pin, 5-pin, axial, axial
Supply voltage 10 V … 32 V
Power consumption ≤ 1.5 W (without load)
MTTFd: mean time to dangerous failure 60 years (EN ISO 13849-1) 1)

1) This product is a standard product and does not constitute a safety component as defined in the Machinery Directive. Calculation based on nominal load of components, average ambient temperature 40°C, frequency of use 8760 h/a. All electronic failures are considered hazardous. For more information, see document no. 8015532.

 

Mechanical Data

Weight 3.78 kg
Measuring wire material Highly flexible stranded steel 1,4401 stainless steel V4A
Measuring wire diameter 1.35 mm
Weight (measuring wire) 7.1 g/m
Housing material, wire draw mechanism Aluminum (anodised), plastic
Spring return force 10 N … 20 N 1)
Length of wire pulled out per revolution 332.4 mm
Life of wire draw mechanism Typ. 1,000,000 cycles 2) 3)
Actual wire draw length 10.2 m
Wire acceleration 40 m/s²
Operating speed 8 m/s
Mounted encoder A3M60, A3M60B-S1PB013X13, 1051018
Mounted mechanic MRA-F130-110D2, 6028627

1) These values were measred at an ambient temperature of 25 °C. There may be variations at other temperatures.

2) Average values, which depend on the application.

3) The service life depends on the type of load. This is influenced by environmental conditions, the installation location, the measuring range in use, the traversing speed, and acceleration.

 

Ambient Data

EMC According to EN 61000-6-2 and EN 61000-6-3
Enclosure rating IP64, mounted mechanic

IP67, Encoder (IEC 60529) 1)

Operating temperature range –10 °C … +70 °C

1) With mating connector fitted.

Additional information

Weight 5.143 kg

Related Products

SICK_sensor_Photoelectric_sensor_W12-2 Laser_WL12G-3V2572S02
Flat Washer M(10)
SICK_sensor_Photoelectric_sensor_W4-3 Glass_WLG4-3P2132
Omron_General-purpose_Slim_Incremental_Rotary_Encoders_E6C2-CWZ1X_2M
M10
Schneider_Inductive Proximity Sensors_XS8C4A1PCG13