Contact Us:
sales@inosaki.com

Circuit breaker size S2 for motor protection, CLASS 10 A-release 14…20 A N-release 260 A – Siemens Motor Starter Protectors

$ 181.93

SKU 3RV2031-4BA10 Category

Features

product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV2
General technical data
size of the circuit-breaker S2
size of contactor can be combined company-specific S2
product extension auxiliary switch Yes
 power loss [W] for rated value of the current
● at AC in hot operating state
● at AC in hot operating state per pole
14.5 W
4.8 W
insulation voltage with degree of pollution 3 at AC rated value 690 V
surge voltage resistance rated value 6 Kv
shock resistance according to IEC 60068-2-27 25g/ 11 ms Sinus
 mechanical service life (operating cycles)
● of the main contacts typical
● of auxiliary contacts typical
50 000
50 000
electrical endurance (operating cycles) typical 50 000
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 10/15/2014
SVHC substance name Lead – 7439-92-1
Weight 1.067 kg
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
 ambient temperature
● during operation-20 … +60 °C
● during storage-50 … +80 °C
● during transport
-20 … +60 °C
-50 … +80 °C
-50 … +80 °C
relative humidity during operation 10 … 95 %
Environmental footprint
global warming potential [CO2 eq] Total 239.877 kg
global warming potential [CO2 eq] during manufacturing 12.8 kg
global warming potential [CO2 eq] during sales 0.477 kg
global warming potential [CO2 eq] during operation 230 kg
global warming potential [CO2 eq] during end of life -3.4 kg
Siemens Eco Profile (SEP) Siemens EcoTech
Main circuit
number of poles for main current circuit 3
adjustable current response value current of the current
dependent overload release
14…20A
operating voltage
● rated value
● at AC-3 rated value maximum
● at AC-3e rated value maximum
20…690 V
690 V
690 V
operating frequency rated value 50…60 Hz
operational current rated value 20 A
operational current
● at AC-3 at 400 V rated value
● at AC-3e at 400 V rated value
20 A
20 A
operating power
● at AC-3
— at 230 V rated value
— at 400 V rated value
— at 500 V rated value
— at 690 V rated value
● at AC-3e
— at 230 V rated value
— at 400 V rated value
— at 500 V rated value
— at 690 V rated value
 

5.5 kW
7.5 kW
11 kW
15 kW

5.5 kW
7.5 kW
11 kW
15 Kw

 operating frequency
● at AC-3 maximum
● at AC-3e maximum
15 1/h
15 1/h
Protective and monitoring functions
 product function
● ground fault detection
● phase failure detection
No
Yes
trip class CLASS 10
design of the overload release thermal
 maximum short-circuit current breaking capacity (Icu)
● at AC at 240 V rated value
● at AC at 400 V rated value
● at AC at 500 V rated value
● at AC at 690 V rated value
100 kA
65 kA
12 kA
5 Ka
 operating short-circuit current breaking capacity (Ics) at AC
● at 240 V rated value
● at 400 V rated value
● at 500 V rated value
● at 690 V rated value
100 kA
30 kA
6 kA
3 kA
response value current of instantaneous short-circuit trip unit 260 A
UL/CSA ratings
 full-load current (FLA) for 3-phase AC motor
● at 480 V rated value
● at 600 V rated value
20 A
20 A
 yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value
— at 230 V rated value
● for 3-phase AC motor
— at 200/208 V rated value
— at 220/230 V rated value
— at 460/480 V rated value
— at 575/600 V rated value
1.5 hp
3 hp

7.5 hp
7.5 hp
15 hp
20 hp

Short-circuit protection
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit”
● at 240 V none required
● at 400 V 100
● at 500 V 80
● at 690 V
none required
100
80
63
Installation/ mounting/ dimensions
mounting position any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
height 140 mm
width 55 mm
depth 149 mm
 required spacing
● with side-by-side mounting at the side 0 mm
● for grounded parts at 400 V
— downwards
— upwards
— at the side
● for live parts at 400 V
— downwards
— upwards
— at the side
● for grounded parts at 500 V
— downwards
— upwards
— at the side
● for live parts at 500 V
— downwards
— upwards
— at the side
● for grounded parts at 690 V
— downwards
— upwards
— at the side
● for live parts at 690 V
— downwards
— upwards
— at the side
0 mm50 mm
50 mm
10 mm

50 mm
50 mm
10 mm

50 mm
50 mm
10 mm

50 mm
50 mm
10 mm

50 mm
50 mm
10 mm

50 mm
50 mm
10 mm

Connections/ Terminals
type of electrical connection
● for main current circuit
 screw-type terminals
arrangement of electrical connectors for main current
circuit
Top and bottom
type of connectable conductor cross-sections
● for main contacts
— solid or stranded
— finely stranded with core end processing
● for AWG cables for main contacts
2x (1 … 25 mm²), 1x (1 … 35 mm²)
2x (1 … 16 mm²), 1x (1 … 25 mm²)
2x (18 … 3), 1x (18 … 2)
 tightening torque
● for main contacts with screw-type terminals
3 … 4.5 N·m
design of screwdriver shaft Diameter 5 to 6 mm
size of the screwdriver tip Pozidriv size 2
 design of the thread of the connection screw
● for main contacts
M6
Safety related data
product function suitable for safety function Yes
 suitability for use
● safety-related switching on
● safety-related switching OFF
No
Yes
service life maximum 10:00 AM
test wear-related service life necessary Yes
 proportion of dangerous failures
● with low demand rate according to SN 31920
● with high demand rate according to SN 31920
40 %
50 %
B10 value with high demand rate according to SN 31920 5 000
failure rate [FIT] with low demand rate according to SN
31920
50 FIT
ISO 13849
device type according to ISO 13849-1 3
overdimensioning according to ISO 13849-2 necessary Yes
IEC 61508
safety device type according to IEC 61508-2 Type A
 T1 value
● for proof test interval or service life according to IEC
61508
10 a
Electrical Safety
protection class IP on the front according to IEC 60529 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front
Display
display version for switching status Handle

Additional information

Weight 1.067 kg
Dimensions 6.2 × 14.7 × 16.7 cm

Related Products