This Acti9 iC60N is a low voltage miniature circuit breaker (MCB). It is a 1P circuit breaker with 1 protected pole, 1A rated current and C tripping curve. The rated short circuit breaking capacity goes up to 50kA at 220VAC to 240VAC conforming to EN/IEC 60947-2 standard and 6000A at 230VAC conforming to EN/IEC 60898-1 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. Its unique VisiTrip indicator reduces intervention time by showing the faulty circuit. Its VisiSafe green strip guarantees the physical opening of the contacts to allow downstream maintenance. Its fast closing mechanism independent of manual operation improves its service life. It has an electrical endurance going up to 10000 cycles and a mechanical endurance going up to 20000 cycles. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to EN/IEC60898-1) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 2 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL9003). The dimensions are (W) 18mm x (H) 85mm x (D) 78.5mm. The weight is 0.215kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -35°C to 70°C. The storage temperature is -40°C to 85°C.

 

Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number A9F74101 A9F74104
Device application Distribution Distribution
Range Acti9 Acti9
Product name Acti9 iC60 Acti9 iC60
Product or component type Miniature circuit-breaker Miniature circuit-breaker
device short name IC60N IC60N
Poles description 1P 1P
Number of protected poles 1 1
[In] rated current 1:00 AM 4:00 AM
Network type DC DC
AC AC
Trip unit technology Thermal-magnetic Thermal-magnetic
Curve code C C
Breaking capacity 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1 6000 A Icn at 230 V AC 50/60 Hz conforming to EN/IEC 60898-1
50 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 12…60 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 220…240 V AC 50/60 Hz conforming to EN/IEC 60947-2
50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2 50 kA Icu at 100…133 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2 10 kA Icu at 60…72 V DC conforming to EN/IEC 60947-2
15 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2 15 kA Icu at 12…60 V DC conforming to EN/IEC 60947-2
Utilisation category Category A conforming to EN 60947-2 Category A conforming to EN 60947-2
Category A conforming to IEC 60947-2 Category A conforming to IEC 60947-2
Suitability for isolation Yes conforming to EN 60898-1 Yes conforming to EN 60898-1
Yes conforming to EN 60947-2 Yes conforming to EN 60947-2
Yes conforming to IEC 60898-1 Yes conforming to IEC 60898-1
Yes conforming to IEC 60947-2 Yes conforming to IEC 60947-2
Standards EN 60898-1 EN 60898-1
EN 60947-2 IEC 60947-2
IEC 60898-1 IEC 60898-1
IEC 60947-2 EN 60947-2
Quality labels NF NF
Complementary
Network frequency 50/60 Hz 50/60 Hz
magnetic tripping limit 8 x In +/- 20 % 8 x In +/- 20 %
[Ics] rated service breaking capacity 50 kA 100 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 – 12…60 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 12…60 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 220…240 V AC 50/60 Hz
50 kA 100 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz 50 kA 100 % conforming to IEC 60947-2 – 100…133 V AC 50/60 Hz
50 kA 100 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz 50 kA 100 % conforming to EN 60947-2 – 100…133 V AC 50/60 Hz
6000 A 100 % conforming to EN 60898-1 – 230 V AC 50/60 Hz 6000 A 100 % conforming to EN 60898-1 – 230 V AC 50/60 Hz
6000 A 100 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz 6000 A 100 % conforming to IEC 60898-1 – 230 V AC 50/60 Hz
10 kA 100 % conforming to EN 60947-2 – 72 V DC 10 kA 100 % conforming to EN 60947-2 – 72 V DC
10 kA 100 % conforming to IEC 60947-2 – 72 V DC 10 kA 100 % conforming to IEC 60947-2 – 72 V DC
15 kA 100 % conforming to EN 60947-2 – 12…60 V DC 15 kA 100 % conforming to EN 60947-2 – 12…60 V DC
15 kA 100 % conforming to IEC 60947-2 – 12…60 V DC 15 kA 100 % conforming to IEC 60947-2 – 12…60 V DC
Limitation class 3 conforming to EN 60898-1 3 conforming to EN 60898-1
3 conforming to IEC 60898-1 3 conforming to IEC 60898-1
[Ui] rated insulation voltage 500 V AC 50/60 Hz conforming to EN 60947-2 500 V AC 50/60 Hz conforming to EN 60947-2
500 V AC 50/60 Hz conforming to IEC 60947-2 500 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to EN 60947-2 6 kV conforming to EN 60947-2
6 kV conforming to IEC 60947-2 6 kV conforming to IEC 60947-2
Contact position indicator Yes Yes
Control type Toggle Toggle
Local signalling Trip indicator Trip indicator
Mounting mode Fixed Fixed
Mounting support DIN rail DIN rail
Comb busbar and distribution block compatibility Top or bottom: YES Top or bottom: YES
9 mm pitches 2 2
Height 85 mm 85 mm
Width 18 mm 18 mm
Depth 78.5 mm 78.5 mm
Product weight 0.215 kg 0.215 kg
Colour White White
Mechanical durability 20000 cycles 20000 cycles
Electrical durability 10000 cycles 10000 cycles
Connections – terminals Single terminal (top or bottom) 1…25 mm² rigid Single terminal (top or bottom) 1…25 mm² rigid
Single terminal (top or bottom) 1…16 mm² flexible Single terminal (top or bottom) 1…16 mm² flexible
Wire stripping length 14 mm for top or bottom connection 14 mm for top or bottom connection
Tightening torque 2 N.m top or bottom 2 N.m top or bottom
Earth-leakage protection Without Without
Environment
IP degree of protection IP20 conforming to IEC 60529 IP20 conforming to IEC 60529
IP20 conforming to EN 60529 IP20 conforming to EN 60529
Pollution degree 3 conforming to EN 60947-2 3 conforming to EN 60947-2
3 conforming to IEC 60947-2 3 conforming to IEC 60947-2
Overvoltage category IV IV
Tropicalisation 2 conforming to IEC 60068-1 2 conforming to IEC 60068-1
Relative humidity 95 % at 55 °C 95 % at 55 °C
Operating altitude 0…2000 m 0…2000 m
Ambient air temperature for operation -35…70 °C -35…70 °C
Ambient air temperature for storage -40…85 °C -40…85 °C
Packing Units
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 9.5 cm 1.7 cm
Package 1 Width 1.7 cm 7.2 cm
Package 1 Length 7.5 cm 9.5 cm
Package 1 Weight 118.0 g 110.0 g
Unit Type of Package 2 BB1 BB1
Number of Units in Package 2 12 12
Package 2 Height 3.0 cm 7.8 cm
Package 2 Width 30.0 cm 9.7 cm
Package 2 Length 20.0 cm 22.3 cm
Package 2 Weight 1.42 kg 1.386 kg
Unit Type of Package 3 S03 S03
Number of Units in Package 3 132 132
Package 3 Height 30.0 cm 30.0 cm
Package 3 Width 30.0 cm 30.0 cm
Package 3 Length 40.0 cm 40.0 cm
Package 3 Weight 16.237 kg 15.742 kg
Contractual warranty
Warranty 18 months 18 months

[/fusion_table]