Specifications

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

ATS48D17Q

ATS48D32Q

ATS48D47Q

ATS48D62Q

Range of product Altistart 48 Altistart 48 Altistart 48 Altistart 48
Product or component type Soft starter Soft starter Soft starter Soft starter
Product destination Asynchronous motors Asynchronous motors Asynchronous motors Asynchronous motors
Product specific application Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps
Device short name ATS48 ATS48 ATS48 ATS48
Utilisation category AC-53A AC-53A AC-53A AC-53A
Ue power supply voltage 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 %
power supply frequency 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 %
motor power kW 7.5 kW at 230 V connection to the motor delta terminals for standard applications
7.5 kW at 400 V connection in the motor supply line for standard applications
11 kW at 400 V connection to the motor delta terminals for severe applications
15 kW at 400 V connection to the motor delta terminals for standard applications
3 kW at 230 V connection in the motor supply line for severe applications
4 kW at 230 V connection in the motor supply line for standard applications
5.5 kW at 230 V connection to the motor delta terminals for severe applications
5.5 kW at 400 V connection in the motor supply line for severe applications
7.5 kW at 230 V connection in the motor supply line for standard applications
9 kW at 230 V connection to the motor delta terminals for severe applications
11 kW at 400 V connection in the motor supply line for severe applications
15 kW at 230 V connection to the motor delta terminals for standard applications
15 kW at 400 V connection in the motor supply line for standard applications
18.5 kW at 400 V connection to the motor delta terminals for severe applications
22 kW at 400 V connection to the motor delta terminals for standard applications
5.5 kW at 230 V connection in the motor supply line for severe applications
9 kW at 230 V connection in the motor supply line for severe applications
11 kW at 230 V connection in the motor supply line for standard applications
18.5 kW at 230 V connection to the motor delta terminals for severe applications
18.5 kW at 400 V connection in the motor supply line for severe applications
22 kW at 230 V connection to the motor delta terminals for standard applications
22 kW at 400 V connection in the motor supply line for standard applications
30 kW at 400 V connection to the motor delta terminals for severe applications
45 kW at 400 V connection to the motor delta terminals for standard applications
55 kW at 400 V connection to the motor delta terminals for standard applications
11 kW at 230 V connection in the motor supply line for severe applications
15 kW at 230 V connection in the motor supply line for standard applications
22 kW at 230 V connection to the motor delta terminals for severe applications
22 kW at 400 V connection in the motor supply line for severe applications
30 kW at 230 V connection to the motor delta terminals for standard applications
30 kW at 400 V connection in the motor supply line for standard applications
45 kW at 400 V connection to the motor delta terminals for severe applications
Complementary
Device connection To the motor delta terminals
In the motor supply line
In the motor supply line
To the motor delta terminals
To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Standards EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2
Product certifications UL
CCC
GOST
DNV
CSA
NOM 117
SEPRO
TCF
C-Tick
NOM 117
CSA
SEPRO
CCC
C-Tick
UL
TCF
DNV
GOST
UL
TCF
NOM 117
GOST
CCC
CSA
DNV
C-Tick
SEPRO
TCF
CSA
DNV
UL
C-Tick
NOM 117
CCC
SEPRO
GOST
Marking CE CE CE CE
Discrete input number 5 5 5 5
discrete input type PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
minimum switching current 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs
Discrete output number 2 2 2 2
discrete output type (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Communication port protocol Modbus Modbus Modbus Modbus
connector type 1 RJ45 1 RJ45 1 RJ45 1 RJ45
Communication data link Serial Serial Serial Serial
Physical interface RS485 multidrop RS485 multidrop RS485 multidrop RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps
Function available External bypass (optional) External bypass (optional) External bypass (optional) External bypass (optional)
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Height 275 mm 275 mm 275 mm 290 mm
Width 160 mm 160 mm 160 mm 190 mm
Depth 190 mm 190 mm 190 mm 235 mm
Net weight 4.9 kg 4.9 kg 4.9 kg 8.3 kg
Environment
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C -25…70 °C
operating altitude <= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 27.0 cm 28.5 cm 28.5 cm 35.4 cm
Package 1 Width 25.0 cm 26 cm 26.0 cm 36.2 cm
Package 1 Length 35.0 cm 37 cm 37.0 cm 44.8 cm
Package 1 Weight 5.682 kg 5.819 kg 5.83 kg 9.246 kg
Unit Type of Package 2 P06 P06 P06 P06
Number of Units in Package 2 8 8 8 2
Package 2 Height 73.5 cm 73.5 cm 73.5 cm 73.5 cm
Package 2 Width 80.0 cm 80 cm 80.0 cm 80.0 cm
Package 2 Length 60.0 cm 60 cm 60.0 cm 60.0 cm
Package 2 Weight 58.456 kg 58.768 kg 58.936 kg 31.792 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

ATS48D75Q

ATS48D88Q

ATS48C11Q

ATS48C14Q

Range of product Altistart 48 Altistart 48 Altistart 48 Altistart 48
Product or component type Soft starter Soft starter Soft starter Soft starter
Product destination Asynchronous motors Asynchronous motors Asynchronous motors Asynchronous motors
Product specific application Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps
Device short name ATS48 ATS48 ATS48 ATS48
Utilisation category AC-53A AC-53A AC-53A AC-53A
Ue power supply voltage 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 %
power supply frequency 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 %
motor power kW 55 kW at 400 V connection to the motor delta terminals for standard applications
55 kW at 400 V connection to the motor delta terminals for severe applications
15 kW at 230 V connection in the motor supply line for severe applications
18.5 kW at 230 V connection in the motor supply line for standard applications
30 kW at 230 V connection to the motor delta terminals for severe applications
30 kW at 400 V connection in the motor supply line for severe applications
37 kW at 230 V connection to the motor delta terminals for standard applications
37 kW at 400 V connection in the motor supply line for standard applications
55 kW at 400 V connection to the motor delta terminals for severe applications
75 kW at 400 V connection to the motor delta terminals for standard applications
18.5 kW at 230 V connection in the motor supply line for severe applications
22 kW at 230 V connection in the motor supply line for standard applications
37 kW at 230 V connection to the motor delta terminals for severe applications
37 kW at 400 V connection in the motor supply line for severe applications
45 kW at 230 V connection to the motor delta terminals for standard applications
45 kW at 400 V connection in the motor supply line for standard applications
55 kW at 230 V connection to the motor delta terminals for standard applications
55 kW at 400 V connection in the motor supply line for standard applications
75 kW at 400 V connection to the motor delta terminals for severe applications
90 kW at 400 V connection to the motor delta terminals for standard applications
22 kW at 230 V connection in the motor supply line for severe applications
30 kW at 230 V connection in the motor supply line for standard applications
45 kW at 230 V connection to the motor delta terminals for severe applications
45 kW at 400 V connection in the motor supply line for severe applications
55 kW at 230 V connection to the motor delta terminals for severe applications
55 kW at 400 V connection in the motor supply line for severe applications
75 kW at 230 V connection to the motor delta terminals for standard applications
75 kW at 400 V connection in the motor supply line for standard applications
90 kW at 400 V connection to the motor delta terminals for severe applications
110 kW at 400 V connection to the motor delta terminals for standard applications
30 kW at 230 V connection in the motor supply line for severe applications
37 kW at 230 V connection in the motor supply line for standard applications
Complementary
Device connection To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Standards EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2
Product certifications DNV
GOST
UL
NOM 117
CCC
CSA
C-Tick
TCF
SEPRO
CCC
CSA
SEPRO
UL
C-Tick
GOST
NOM 117
TCF
DNV
C-Tick
GOST
SEPRO
NOM 117
CSA
TCF
DNV
CCC
UL
CSA
UL
DNV
GOST
NOM 117
C-Tick
SEPRO
CCC
TCF
Marking CE CE CE CE
Discrete input number 5 5 5 5
discrete input type PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
minimum switching current 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs
Discrete output number 2 2 2 2
discrete output type (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Communication port protocol Modbus Modbus Modbus Modbus
connector type 1 RJ45 1 RJ45 1 RJ45 1 RJ45
Communication data link Serial Serial Serial Serial
Physical interface RS485 multidrop RS485 multidrop RS485 multidrop RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps
Function available External bypass (optional) External bypass (optional) External bypass (optional) External bypass (optional)
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Height 290 mm 290 mm 290 mm 340 mm
Width 190 mm 190 mm 190 mm 200 mm
Depth 235 mm 235 mm 235 mm 265 mm
Net weight 8.3 kg 8.3 kg 8.3 kg 12.4 kg
Environment
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C -25…70 °C
operating altitude <= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 36 cm 35.2 cm 35.5 cm 32.0 cm
Package 1 Width 30.5 cm 35.8 cm 30.5 cm 46.0 cm
Package 1 Length 39 cm 44.8 cm 39.0 cm 42.5 cm
Package 1 Weight 10.266 kg 9.204 kg 9.27 kg 13.688 kg
Unit Type of Package 2 P06 P06 P06 P06
Number of Units in Package 2 2 2 2 2
Package 2 Height 73.5 cm 73.5 cm 73.5 cm 73.5 cm
Package 2 Width 80 cm 80.0 cm 80.0 cm 80.0 cm
Package 2 Length 60 cm 60.0 cm 60.0 cm 60.0 cm
Package 2 Weight 33.532 kg 31.896 kg 31.774 kg 41.96 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

ATS48C17Q

ATS48C21Q

ATS48C25Q

ATS48C32Q

Range of product Altistart 48 Altistart 48 Altistart 48 Altistart 48
Product or component type Soft starter Soft starter Soft starter Soft starter
Product destination Asynchronous motors Asynchronous motors Asynchronous motors Asynchronous motors
Product specific application Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps
Device short name ATS48 ATS48 ATS48 ATS48
Utilisation category AC-53A AC-53A AC-53A AC-53A
Ue power supply voltage 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 %
power supply frequency 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 %
motor power kW 75 kW at 230 V connection to the motor delta terminals for severe applications
75 kW at 400 V connection in the motor supply line for severe applications
90 kW at 230 V connection to the motor delta terminals for standard applications
90 kW at 400 V connection in the motor supply line for standard applications
110 kW at 400 V connection to the motor delta terminals for severe applications
132 kW at 400 V connection to the motor delta terminals for standard applications
37 kW at 230 V connection in the motor supply line for severe applications
45 kW at 230 V connection in the motor supply line for standard applications
55 kW at 230 V connection in the motor supply line for standard applications
90 kW at 230 V connection to the motor delta terminals for severe applications
90 kW at 400 V connection in the motor supply line for severe applications
110 kW at 230 V connection to the motor delta terminals for standard applications
110 kW at 400 V connection in the motor supply line for standard applications
132 kW at 400 V connection to the motor delta terminals for severe applications
160 kW at 400 V connection to the motor delta terminals for standard applications
45 kW at 230 V connection in the motor supply line for severe applications
55 kW at 230 V connection in the motor supply line for severe applications
75 kW at 230 V connection in the motor supply line for standard applications
110 kW at 230 V connection to the motor delta terminals for severe applications
110 kW at 400 V connection in the motor supply line for severe applications
132 kW at 230 V connection to the motor delta terminals for standard applications
132 kW at 400 V connection in the motor supply line for standard applications
160 kW at 400 V connection to the motor delta terminals for severe applications
220 kW at 400 V connection to the motor delta terminals for standard applications
75 kW at 230 V connection in the motor supply line for severe applications
90 kW at 230 V connection in the motor supply line for standard applications
132 kW at 230 V connection to the motor delta terminals for severe applications
132 kW at 400 V connection in the motor supply line for severe applications
160 kW at 230 V connection to the motor delta terminals for standard applications
160 kW at 400 V connection in the motor supply line for standard applications
220 kW at 400 V connection to the motor delta terminals for severe applications
250 kW at 400 V connection to the motor delta terminals for standard applications
Complementary
Device connection To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
To the motor delta terminals
In the motor supply line
In the motor supply line
To the motor delta terminals
protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Standards EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2
Product certifications C-Tick
NOM 117
CCC
GOST
TCF
DNV
SEPRO
CSA
UL
GOST
SEPRO
CSA
C-Tick
NOM 117
TCF
UL
CCC
DNV
C-Tick
CCC
UL
NOM 117
CSA
DNV
SEPRO
GOST
TCF
C-Tick
CCC
DNV
SEPRO
NOM 117
CSA
TCF
GOST
UL
Marking CE CE CE CE
Discrete input number 5 5 5 5
discrete input type PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
minimum switching current 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs
Discrete output number 2 2 2 2
discrete output type (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Communication port protocol Modbus Modbus Modbus Modbus
connector type 1 RJ45 1 RJ45 1 RJ45 1 RJ45
Communication data link Serial Serial Serial Serial
Physical interface RS485 multidrop RS485 multidrop RS485 multidrop RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps
Function available External bypass (optional) External bypass (optional) External bypass (optional) External bypass (optional)
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Height 340 mm 380 mm 380 mm 380 mm
Width 200 mm 320 mm 320 mm 320 mm
Depth 265 mm 265 mm 265 mm 265 mm
Net weight 12.4 kg 18.2 kg 18.2 kg 18.2 kg
Environment
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C -25…70 °C
operating altitude <= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 43 cm 72.000 cm 42.000 cm 42.500 cm
Package 1 Width 33 cm 80.000 cm 46.000 cm 46.000 cm
Package 1 Length 46 cm 60.000 cm 51.500 cm 51.000 cm
Package 1 Weight 13.816 kg 21.000 kg 21.636 kg 20.000 kg
Unit Type of Package 2 P06 N/A
Number of Units in Package 2 2
Package 2 Height 73.5 cm
Package 2 Width 80 cm
Package 2 Length 60 cm
Package 2 Weight 40 kg
Contractual warranty
Warranty 18 months 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number

ATS48C32Y

ATS48C41Q

ATS48C48Q

Range of product Altistart 48 Altistart 48 Altistart 48
Product or component type Soft starter Soft starter Soft starter
Product destination Asynchronous motors Asynchronous motors Asynchronous motors
Product specific application Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps
Device short name ATS48 ATS48 ATS48
Utilisation category AC-53A AC-53A AC-53A
Ue power supply voltage 208…690 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 %
power supply frequency 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 %
motor power kW 132 kW at 400 V for severe applications
132 kW at 440 V for severe applications
160 kW at 400 V for standard applications
160 kW at 440 V for standard applications
160 kW at 500 V for severe applications
160 kW at 525 V for severe applications
220 kW at 500 V for standard applications
220 kW at 525 V for standard applications
220 kW at 660 V for severe applications
250 kW at 660 V for standard applications
250 kW at 690 V for severe applications
315 kW at 690 V for standard applications
75 kW at 230 V for severe applications
90 kW at 230 V for standard applications
90 kW at 230 V connection in the motor supply line for severe applications
110 kW at 230 V connection in the motor supply line for standard applications
160 kW at 230 V connection to the motor delta terminals for severe applications
160 kW at 400 V connection in the motor supply line for severe applications
220 kW at 230 V connection to the motor delta terminals for standard applications
220 kW at 400 V connection in the motor supply line for standard applications
250 kW at 400 V connection to the motor delta terminals for severe applications
315 kW at 400 V connection to the motor delta terminals for standard applications
110 kW at 230 V connection in the motor supply line for severe applications
132 kW at 230 V connection in the motor supply line for standard applications
220 kW at 230 V connection to the motor delta terminals for severe applications
220 kW at 400 V connection in the motor supply line for severe applications
250 kW at 230 V connection to the motor delta terminals for standard applications
250 kW at 400 V connection in the motor supply line for standard applications
315 kW at 400 V connection to the motor delta terminals for severe applications
355 kW at 400 V connection to the motor delta terminals for standard applications
motor power hp 100 hp at 208 V for standard applications
100 hp at 230 V for severe applications
125 hp at 230 V for standard applications
200 hp at 460 V for severe applications
250 hp at 460 V for standard applications
250 hp at 575 V for severe applications
300 hp at 575 V for standard applications
75 hp at 208 V for severe applications
Complementary
Device connection In the motor supply line In the motor supply line
To the motor delta terminals
To the motor delta terminals
In the motor supply line
protection type Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Phase failure: line
Thermal protection: motor
Thermal protection: starter
Standards EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2
Product certifications C-Tick
NOM 117
SEPRO
CSA
UL
CCC
TCF
DNV
GOST
DNV
C-Tick
CSA
NOM 117
TCF
UL
SEPRO
GOST
CCC
CSA
GOST
DNV
TCF
UL
C-Tick
NOM 117
CCC
SEPRO
Marking CE CE CE
Discrete input number 5 5 5
discrete input type PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
minimum switching current 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs
Discrete output number 2 2 2
discrete output type (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Communication port protocol Modbus Modbus Modbus
connector type 1 RJ45 1 RJ45 1 RJ45
Communication data link Serial Serial Serial
Physical interface RS485 multidrop RS485 multidrop RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps
Function available External bypass (optional) External bypass (optional) External bypass (optional)
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Height 380 mm 670 mm 670 mm
Width 320 mm 400 mm 400 mm
Depth 265 mm 300 mm 300 mm
Net weight 18.2 kg 51.4 kg 51.4 kg
Environment
electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Conducted and radiated emissions level A conforming to IEC 60947-4-2
Damped oscillating waves level 3 conforming to IEC 61000-4-12
Electrostatic discharge level 3 conforming to IEC 61000-4-2
Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Voltage/current impulse level 3 conforming to IEC 61000-4-5
relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C
operating altitude <= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
<= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 75.000 cm 39 cm 39 cm
Package 1 Width 60.000 cm 58 cm 60 cm
Package 1 Length 80.000 cm 78.5 cm 78 cm
Package 1 Weight 33.000 kg 54.5 kg 53.5 kg
Contractual warranty
Warranty 18 months 18 months 18 months

[/fusion_table]

 

[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Main
Part Number ATS48D17Q ATS48C59Q ATS48C79Q
Range of product Altistart 48 Altistart 48 Altistart 48
Product or component type Soft starter Soft starter Soft starter
Product destination Asynchronous motors Asynchronous motors Asynchronous motors
Product specific application Heavy duty industry and pumps Heavy duty industry and pumps Heavy duty industry and pumps
Device short name ATS48 ATS48 ATS48
utilisation category AC-53A AC-53A AC-53A
Ue power supply voltage 230…415 V – 15…10 % 230…415 V – 15…10 % 230…415 V – 15…10 %
power supply frequency 50…60 Hz – 5…5 % 50…60 Hz – 5…5 % 50…60 Hz – 5…5 %
Motor power kW 7.5 kW at 230 V connection to the motor delta terminals for standard applications 132 kW at 230 V connection in the motor supply line for severe applications 630 kW at 400 V connection to the motor delta terminals for standard applications
7.5 kW at 400 V connection in the motor supply line for standard applications 160 kW at 230 V connection in the motor supply line for standard applications 220 kW at 230 V connection in the motor supply line for standard applications
11 kW at 400 V connection to the motor delta terminals for severe applications 250 kW at 230 V connection to the motor delta terminals for severe applications 315 kW at 230 V connection to the motor delta terminals for severe applications
15 kW at 400 V connection to the motor delta terminals for standard applications 250 kW at 400 V connection in the motor supply line for severe applications 355 kW at 230 V connection to the motor delta terminals for standard applications
3 kW at 230 V connection in the motor supply line for severe applications 315 kW at 400 V connection in the motor supply line for standard applications 355 kW at 400 V connection in the motor supply line for severe applications
4 kW at 230 V connection in the motor supply line for standard applications 355 kW at 400 V connection to the motor delta terminals for severe applications 400 kW at 400 V connection in the motor supply line for standard applications
5.5 kW at 230 V connection to the motor delta terminals for severe applications 400 kW at 400 V connection to the motor delta terminals for standard applications 500 kW at 400 V connection to the motor delta terminals for severe applications
5.5 kW at 400 V connection in the motor supply line for severe applications
Complementary
Device connection To the motor delta terminals To the motor delta terminals In the motor supply line
In the motor supply line In the motor supply line To the motor delta terminals
Protection type Phase failure: line Phase failure: line Phase failure: line
Thermal protection: motor Thermal protection: motor Thermal protection: motor
Thermal protection: starter Thermal protection: starter Thermal protection: starter
Standards EN/IEC 60947-4-2 EN/IEC 60947-4-2 EN/IEC 60947-4-2
Product certifications UL TCF SEPRO
CCC DNV C-Tick
GOST UL TCF
DNV CCC GOST
CSA CSA UL
NOM 117 NOM 117 CCC
SEPRO SEPRO CSA
TCF GOST DNV
C-Tick C-Tick NOM 117
marking CE CE CE
Discrete input number 5 5 5
Discrete input type PTC, 750 Ohm at 25 °C PTC, 750 Ohm at 25 °C PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
Discrete input logic Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
Minimum switching current 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs 10 mA at 6 V DC for relay outputs
Discrete output number 2 2 2
Discrete output type (LO1) logic output 0 V common configurable (LO1) logic output 0 V common configurable (LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable (LO2) logic output 0 V common configurable (LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO (R1) relay outputs fault relay NO (R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO (R2) relay outputs end of starting relay NO (R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO (R3) relay outputs motor powered NO (R3) relay outputs motor powered NO
Analogue output type Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
Communication port protocol Modbus Modbus Modbus
Connector type 1 RJ45 1 RJ45 1 RJ45
Communication data link Serial Serial Serial
Physical interface RS485 multidrop RS485 multidrop RS485 multidrop
Transmission rate 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps 4800, 9600 or 19200 bps
Function available External bypass (optional) External bypass (optional) External bypass (optional)
Operating position Vertical +/- 10 degree Vertical +/- 10 degree Vertical +/- 10 degree
Height 275 mm 670 mm 890 mm
Width 160 mm 400 mm 770 mm
Depth 190 mm 300 mm 315 mm
Net weight 4.9 kg 51.4 kg 115 kg
Environment
Electromagnetic compatibility Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level A conforming to IEC 60947-4-2 Conducted and radiated emissions level A conforming to IEC 60947-4-2
Conducted and radiated emissions level B conforming to IEC 60947-4-2 Damped oscillating waves level 3 conforming to IEC 61000-4-12 Damped oscillating waves level 3 conforming to IEC 61000-4-12
Damped oscillating waves level 3 conforming to IEC 61000-4-12 Electrostatic discharge level 3 conforming to IEC 61000-4-2 Electrostatic discharge level 3 conforming to IEC 61000-4-2
Electrostatic discharge level 3 conforming to IEC 61000-4-2 Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to electrical transients level 4 conforming to IEC 61000-4-4
Immunity to electrical transients level 4 conforming to IEC 61000-4-4 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3
Immunity to radiated radio-electrical interference level 3 conforming to IEC 61000-4-3 Voltage/current impulse level 3 conforming to IEC 61000-4-5 Voltage/current impulse level 3 conforming to IEC 61000-4-5
Voltage/current impulse level 3 conforming to IEC 61000-4-5
Relative humidity 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3 0…95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
Ambient air temperature for operation 40…60 °C (with current derating of 2 % per °C) 40…60 °C (with current derating of 2 % per °C) 40…60 °C (with current derating of 2 % per °C)
-10…40 °C (without derating) -10…40 °C (without derating) -10…40 °C (without derating)
Ambient air temperature for storage -25…70 °C -25…70 °C -25…70 °C
Operating altitude <= 1000 m without derating <= 1000 m without derating <= 1000 m without derating
> 1000…2000 m with current derating of 2.2 % per additional 100 m > 1000…2000 m with current derating of 2.2 % per additional 100 m > 1000…2000 m with current derating of 2.2 % per additional 100 m
Packing Units
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 27.0 cm 39.0 cm 61.000 cm
Package 1 Width 25.0 cm 58.5 cm 91.000 cm
Package 1 Length 35.0 cm 78.0 cm 103.000 cm
Package 1 Weight 5.682 kg 53.025 kg 123.000 kg
Unit Type of Package 2 P06 P06
Number of Units in Package 2 8 1
Package 2 Height 73.5 cm 52.0 cm
Package 2 Width 80.0 cm 54.0 cm
Package 2 Length 60.0 cm 82.0 cm
Package 2 Weight 58.456 kg 62.94 kg
Contractual warranty
Warranty 18 months 18 months 18 months

[/fusion_table]

 

Weight N/A
Dimensions N/A