Part Number: 1048811
Non-contact safety switches: C4MT-01214ABB03BE0
OEM Spec Ref
| System part | 2 Twin-Sticks | ||||||
| Usage | miniTwin4 as a standalone device
miniTwin4 as last guest for 2- or 3-device cascade |
||||||
| Mounting system type | C-fix or L-fix bracket | ||||||
| Resolution | 14 mm | ||||||
|
|||||||
| Protective field height | 120 mm | ||||||
| Response time | ≤ 14 ms 1) | ||||||
| Synchronization | Optical, without separate synchronization | ||||||
| Items supplied | Twin stick
System plug C-Fix bracket and L-Fix bracket, 2 pieces each Test rod with diameter corresponding to the resolution of the safety light curtain Safety instruction Mounting instructions Operating instructions for download |
||||||
| Type | Type 4 (IEC 61496-1) |
| Safety integrity level | SIL3 (IEC 61508)
SILCL3 (EN 62061) |
| Category | Category 4 (EN ISO 13849) |
| Performance level | PL e (EN ISO 13849) |
| PFHD (mean probability of a dangerous failure per hour) | Standalone system: 4.3 x 10-9 (EN ISO 13849) |
| TM (mission time) | 20 years (EN ISO 13849) |
| Safe state in the event of a fault | At least one OSSD is in the OFF state. |
| Functions | Delivery status | |
|---|---|---|
| Restart interlock | ✔ | Deactivated |
| External device monitoring (EDM) | ✔ | Deactivated |
| Beam coding | Automatic | |
|
|||||||||||||||||
| Configuration method | Hard wired | ||||||||||||||||
| Display elements | LEDs | ||||||||||||||||
|
|||||||||||||||||
| Protection class | III (EN 61140) | ||||||||||
| Supply voltage VS | 24 V DC (19.2 V DC … 28.8 V DC) | ||||||||||
| Ripple | ≤ 10 % 1) | ||||||||||
| Power consumption | ≤ 3 A 2) | ||||||||||
|
|||||||||||
Mechanical data
| Housing cross-section (incl. system connection) | 15 mm x 32 mm |
| Housing material | Aluminum alloy ALMGSI 0.5 |
| Weight | 50 g |
Ambient data
| Enclosure rating | IP65 (EN 60529) |
| Ambient operating temperature | –20 °C … +55 °C |
| Storage temperature | –25 °C … +70 °C |
| Air humidity | 15 % … 95 %, Non-condensing |
| Vibration resistance | 5 g, 10 Hz … 55 Hz (EN 60068-2-6) |
| Shock resistance | 10 g, 16 ms (EN 60068-2-27) |