SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6058148
Capacitive Proximity Sensor Model: CM30-16BAP-KW1
OEM Spec Ref
Features
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Housing | Cylindrical thread design |
Thread size | M18 x 1 |
Diameter | Ø 18 mm |
Sensing range Sn | 3 mm … 12 mm |
Safe sensing range Sa | 9.18 mm 1) |
Installation type | Non-flush |
Switching frequency | 50 Hz |
Connection type | Cable, 4-wire, 2 m 2) |
Switching output | PNP |
Output function | Complementary |
Output characteristic | Wire configurable |
Electrical wiring | DC 4-wire |
Adjustment | Potentiometer (Sensitivity) |
Enclosure rating | IP68, IP69K 3) |
Authorizations | Ecolab 4)
CE-conformity cULus |
[/fusion_table]
- 1) For flush mounting in electrically conductive materials Sa = 0.8 x Sr at temperatures <0 °C and >60 °C.
- 2) Do not bend below 0 °C.
- 3) 1 m water depth / 60 min.
- 4) P3-topax 19, P3-topax 56, P3-topax 66, P3-topactive DES.
Mechanics/electronics
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Supply voltage | 10 V DC … 36 V DC |
Ripple | ≤ 10 % 1) |
Voltage drop | ≤ 2.5 V DC 2) |
Current consumption | 12 mA 3) |
Time delay before availability | ≤ 200 ms |
Hysteresis | 3 % … 20 % |
Reproducibility | ≤ 5 % 4) 5) |
Temperature drift (of Sr) | ± 10 % |
EMC | According to EN 60947-5-2 |
Continuous current Ia | ≤ 200 mA |
Cable material | PVC |
Conductor size | 0.34 mm² |
Cable diameter | Ø 5.2 mm |
Short-circuit protection | ✔ |
Reverse polarity protection | ✔ |
Power-up pulse protection | ✔ |
Shock and vibration resistance | According to EN 60068 |
Ambient operating temperature | –30 °C … +85 °C 6) |
Ambient temperature, storage | –40 °C … +85 °C |
Housing material | Plastic, PBT |
Housing length | 86 mm |
Thread length | 47 mm |
Tightening torque, max. | ≤ 2.6 Nm |
Items supplied | Mounting nut, PA12 plastic (2x)
Screwdriver for potentiometer adjustment (1 x) |
UL File No. | NRKH.E191603 |
[/fusion_table]
- 1) Of Ub.
- 2) At Ia max.
- 3) Without load.
- 4) Of Sr.
- 5) Ub and Ta constant.
- 6) +120 °C short time, at the front of the sensor.
Safety-related parameters
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
MTTFD | 919 years |
DCavg | 0 % |
TM (mission time) | 20 years |
[/fusion_table]
Reduction factors
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Note | The values are reference values which may vary |
Metal | 1 |
Water | 1 |
PVC | Approx. 0.4 |
Oil | Approx. 0.25 |
Glass | 0.6 |
Ceramics | 0.5 |
Alcohol | 0.7 |
Wood | 0.2 … 0.7 |
[/fusion_table]