Manufacturer Part Number: Festo 1971599
Festo Remote I/O and Network Interface Components: CPX-FVDA-P2
The Festo CPX-FVDA-P2, with MPN 1971599 remote I/O and network interface component, is a robust output module designed to streamline and enhance the control capabilities within industrial automation systems. This component is ideal for a variety of applications, ensuring reliable operation and integration into diverse industrial environments.
Key Features:
Benefits:
Applications:
The Festo CPX-FVDA-P2 remote I/O and network interface component stands as a testament to Festo’s commitment to providing sophisticated solutions for managing industrial automation, ensuring that systems operate at their peak performance and reliability.
| Feature | Specification | 
|---|---|
| Dimensions W x L x H | (incl. interlinking block and connection system) 50 mm x 107 mm x 55 mm | 
| Product weight | 50 g | 
| Ambient temperature | -5 °C … 50 °C | 
| Note on ambient temperature | Observe derating curve for pneumatic interface | 
| Storage temperature | -20 °C … 70 °C | 
| Degree of protection | Depends on manifold block | 
| Corrosion resistance class (CRC) | 1 – Low corrosion stress (when installed) | 
| Max. cable length | 200 m | 
| LABS (PWIS) conformity | VDMA24364-B2-L | 
| CE marking (see declaration of conformity) | As per EU EMC directive as per EU machinery directive As per EU RoHS directive | 
| UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK instructions for machines To UK RoHS instructions | 
| Certification | c UL us – Recognized (OL) | 
| Certificate issuing authority | German Technical Control Board (TÜV) Rhld 01/205/5294.02/23 German Technical Control Board (TÜV) Rhld 01/205U/5294.01/23 | 
| Note on materials | RoHS-compliant | 
| Housing material | PA-reinforced PC | 
| PFH | 1.0E-9 | 
| LED indicators | 1 fail-safe mode protocol active 1 group diagnostics 3 channel diagnostics 3 channel status | 
| Diagnostics | Wire break per channel Short circuit/overload per channel Cross circuit Undervoltage of pneumatic valves | 
| Max. address capacity inputs | 6 byte | 
| Max. address capacity outputs | 6 byte | 
| No. of outputs | 2 | 
| Note on outputs | 1 internal channel for switching off pneumatic valve voltage 2 external outputs | 
| Parameterization | Diagnostic behavior Wire break monitoring per channel | 
| Nominal operating voltage DC | 24 V | 
| Permissible voltage fluctuations | -15 % / +20 % | 
| Residual ripple | 2 Vss within voltage range | 
| Intrinsic current consumption at nominal operating voltage | Typ. 25 mA (electronics operating voltage supply) Typ. 65 mA (pneumatic valve load power supply) | 
| Load capacity to FE | 400 nF | 
| Switching logic at outputs | PM-switching | 
| Max. response time to switch off command | F_WD_TIME + 23 ms | 
| Safety function | Safely switching off supply voltage for the pneumatic valves | 
| Safety integrity level (SIL) | Safe switch-off/SIL 3 | 
| Performance Level (PL) | Safe switch-off/category 3, performance level e | 
| Max. power supply per channel | 1.5 A | 
| Max. residual current per module | 5 A | 
| Voltage drop per channel | 0.6 V | 
| Electrical isolation between channels | no | 
| Electrical isolation between channel and internal bus | Yes, when using intermediate feed | 
| Fuse protection (short circuit) | Internal electronic fuse per channel | 
| Weight | 0.050 kg | 
|---|