[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”” margin_right=”” margin_bottom=”” margin_left=”” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]

Item Specifications
Product Number DP-101-M-P
Part Number DP-101-M-P
CE marking directive compliance EMC Directive, RoHS Directive
Type of pressure Gauge pressure
Rated pressure range -100.0 to +100.0 kPa
Set pressure range -101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to +1.010 bar
-14.64 to +14.64 psi
-757 to +757 mmHg
-29.8 to 29.8 inHg
Pressure withstandability 500 kPa
Applicable fluid Non-corrosive gas
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Power consumption Normal operation :
720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode :
480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
Comparative output <PNP output>
PNP open-collector transistor
– Maximum source current : 100 mA
– Applied voltage : 30 V DC or less (between comparative output and +V)
– Residual voltage : 2 V or less (at 100 mA source current)
Comparative output : Output operation NO / NC (selectable by key operation)
Comparative output : Output modes EASY mode / Hysteresis mode / Window comparator mode
Comparative output : Hysteresis Minimum 1 digit (variable)(however, 2 digits when using psi unit)
Comparative output : Repeatability ±0.1 % F.S.
(within ±2 digits)
Comparative output : Response time 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Comparative output : Short-circuit protection Incorporated
External input
Analog voltage output
Analog current output
Display 4 digits + 4 digits 3-color LCD display
(Display refresh rate : 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Display : Displayable pressure range -101.0 to +101.0 kPa
-1.030 to +1.030 kgf/cm2
-1.010 to +1.010 bar
-14.64 to +14.64 psi
-757 to +757 mmHg
-29.8 to 29.8 inHg
Indicator Orange LED
(Comparative output 1 operation indicator, comparative output 2 operation indicator : Lights up when each comparative output is ON)
Protection IP40 (IEC)
Ambient temperature -10 to +50 ℃ +14 to +122 ℉, Storage : -10 to +60 ℃ +14 to +140 ℉
Ambient humidity 35 to 85 % RH (No dew condensation or icing allowed), Storage : 35 to 85 % RH
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Temperature characteristics Within ±0.5 % F.S.
(at +20 ℃ +68 ℉)
Material Enclosure : PBT (glass fiber reinforced), LCD display : Acrylic, Pressure port : Stainless steel (SUS303), Mounting threaded part : Brass (nickel plated), Switch part : Silicone rubber
Connecting method Connector
Cable length Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable
Weight Net weight: 30 g approx., Gross weight: 120 g approx.
Accessories CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type)

[/fusion_table]

Weight 0.03 kg