Specifications
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main | ||||
Part Number | ATV610U07N4 | ATV610U15N4 | ATV610U22N4 | ATV610U30N4 |
Range of product | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor |
Device short name | ATV610 | ATV610 | ATV610 | ATV610 |
Variant | Standard version | Standard version | Standard version | Standard version |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 | IP20 | IP20 | IP20 |
Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection |
supply frequency | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % |
network number of phases | 3 phases | 3 phases | 3 phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % |
motor power kW | 0.75 kW for normal duty | 1.5 kW for normal duty | 2.2 kW for normal duty | 3 kW for normal duty |
0.37 kW for heavy duty | 0.75 kW for heavy duty | 1.5 kW for heavy duty | 2.2 kW for heavy duty | |
motor power hp | 1 hp for normal duty | 2 hp for normal duty | 3 hp for normal duty | 3 hp for heavy duty |
0.5 hp for heavy duty | 1 hp for heavy duty | 2 hp for heavy duty | ||
line current | 3.1 A at 380 V (normal duty) | 5.7 A at 380 V (normal duty) | 7.8 A at 380 V (normal duty) | 10.1 A at 380 V (normal duty) |
2.6 A at 460 V (normal duty) | 4.8 A at 460 V (normal duty) | 6.5 A at 460 V (normal duty) | 8.4 A at 460 V (normal duty) | |
1.7 A at 380 V (heavy duty) | 3.1 A at 380 V (heavy duty) | 5.6 A at 380 V (heavy duty) | 7.6 A at 380 V (heavy duty) | |
1.4 A at 460 V (heavy duty) | 2.6 A at 460 V (heavy duty) | 4.6 A at 460 V (heavy duty) | 6.4 A at 460 V (heavy duty) | |
Prospective line Isc | 5 kA | 5 kA | 5 kA | 5 kA |
apparent power | 2.1 kVA at 460 V (normal duty) | 3.8 kVA at 460 V (normal duty) | 5.2 kVA at 460 V (normal duty) | 6.7 kVA at 460 V (normal duty) |
1.1 kVA at 460 V (heavy duty) | 2.1 kVA at 460 V (heavy duty) | 3.7 kVA at 460 V (heavy duty) | 5.1 kVA at 460 V (heavy duty) | |
continuous output current | 2.2 A at 4 kHz for normal duty | 4 A at 4 kHz for normal duty | 5.6 A at 4 kHz for normal duty | 7.2 A at 4 kHz for normal duty |
1.5 A at 4 kHz for heavy duty | 2.2 A at 4 kHz for heavy duty | 4 A at 4 kHz for heavy duty | 5.6 A at 4 kHz for heavy duty | |
maximum transient current | 2.4 A during 60 s (normal duty) | 4.4 A during 60 s (normal duty) | 6.2 A during 60 s (normal duty) | 7.9 A during 60 s (normal duty) |
2.3 A during 60 s (heavy duty) | 3.3 A during 60 s (heavy duty) | 6 A during 60 s (heavy duty) | 8.4 A during 60 s (heavy duty) | |
Asynchronous motor control profile | Constant torque standard | Optimized torque mode | Variable torque standard | Constant torque standard |
Optimized torque mode | Constant torque standard | Optimized torque mode | Variable torque standard | |
Variable torque standard | Variable torque standard | Constant torque standard | Optimized torque mode | |
Output frequency | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz |
Nominal switching frequency | 4 kHz | 4 kHz | 4 kHz | 4 kHz |
switching frequency | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable |
number of preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds |
Communication port protocol | Modbus serial | Modbus serial | Modbus serial | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | |
Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 19.0 cm | 19.6 cm | 19.0 cm | 19.0 cm |
Package 1 Width | 30.5 cm | 12.8 cm | 30.5 cm | 30.5 cm |
Package 1 Length | 40.5 cm | 28.0 cm | 41.0 cm | 41.0 cm |
Package 1 Weight | 4.245 kg | 5.7 kg | 4.313 kg | 4.383 kg |
Unit Type of Package 2 | S06 | S06 | S06 | |
Number of Units in Package 2 | 6 | 6 | 6 | |
Package 2 Height | 75.0 cm | 75.0 cm | 75.0 cm | |
Package 2 Width | 80.0 cm | 80.0 cm | 80.0 cm | |
Package 2 Length | 60.0 cm | 60.0 cm | 60.0 cm | |
Package 2 Weight | 33.47 kg | 33.878 kg | 34.298 kg |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main | ||||
Part Number | ATV610U40N4 | ATV610U55N4 | ATV610U75N4 | ATV610D11N4 |
Range of product | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor |
Device short name | ATV610 | ATV610 | ATV610 | ATV610 |
Variant | Standard version | Standard version | Standard version | Standard version |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 | IP20 | IP20 | IP20 |
Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection |
supply frequency | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % |
network number of phases | 3 phases | 3 phases | 3 phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % |
motor power kW | 4 kW for normal duty | 5.5 kW for normal duty | 7.5 kW for normal duty | 11 kW for normal duty |
3 kW for heavy duty | 4 kW for heavy duty | 5.5 kW for heavy duty | 7.5 kW for heavy duty | |
motor power hp | 5 hp for normal duty | 7.5 hp for normal duty | 10 hp for normal duty | 15 hp for normal duty |
5 hp for heavy duty | 7.5 hp for heavy duty | 10 hp for heavy duty | ||
line current | 8.8 A at 380 V (normal duty) | 11.6 A at 380 V (normal duty) | 14.7 A at 380 V (normal duty) | 22 A at 380 V (normal duty) |
7.9 A at 460 V (normal duty) | 10.5 A at 460 V (normal duty) | 12.8 A at 460 V (normal duty) | 19.6 A at 460 V (normal duty) | |
7.2 A at 380 V (heavy duty) | 8.9 A at 380 V (heavy duty) | 11.3 A at 380 V (heavy duty) | 16.4 A at 380 V (heavy duty) | |
6.2 A at 460 V (heavy duty) | 7.9 A at 460 V (heavy duty) | 10.2 A at 460 V (heavy duty) | 14.6 A at 460 V (heavy duty) | |
Prospective line Isc | 5 kA | 22 kA | 22 kA | 22 kA |
apparent power | 6.3 kVA at 460 V (normal duty) | 8.4 kVA at 460 V (normal duty) | 10.2 kVA at 460 V (normal duty) | 15.6 kVA at 460 V (normal duty) |
4.9 kVA at 460 V (heavy duty) | 6.3 kVA at 460 V (heavy duty) | 8.1 kVA at 460 V (heavy duty) | 11.6 kVA at 460 V (heavy duty) | |
continuous output current | 9.3 A at 4 kHz for normal duty | 12.7 A at 4 kHz for normal duty | 15.8 A at 4 kHz for normal duty | 23.5 A at 4 kHz for normal duty |
7.2 A at 4 kHz for heavy duty | 9.3 A at 4 kHz for heavy duty | 12.7 A at 4 kHz for heavy duty | 16.5 A at 4 kHz for heavy duty | |
maximum transient current | 10.2 A during 60 s (normal duty) | 14 A during 60 s (normal duty) | 17.4 A during 60 s (normal duty) | 25.9 A during 60 s (normal duty) |
10.8 A during 60 s (heavy duty) | 14 A during 60 s (heavy duty) | 19.1 A during 60 s (heavy duty) | 24.8 A during 60 s (heavy duty) | |
Asynchronous motor control profile | Optimized torque mode | Optimized torque mode | Constant torque standard | Constant torque standard |
Variable torque standard | Variable torque standard | Optimized torque mode | Optimized torque mode | |
Constant torque standard | Constant torque standard | Variable torque standard | Variable torque standard | |
Output frequency | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz |
Nominal switching frequency | 4 kHz | 4 kHz | 4 kHz | 4 kHz |
switching frequency | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable |
number of preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds |
Communication port protocol | Modbus serial | Modbus serial | Modbus serial | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | |
Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 19.6 cm | 17.5 cm | 18.5 cm | 21.5 cm |
Package 1 Width | 12.8 cm | 31.0 cm | 31.0 cm | 34.0 cm |
Package 1 Length | 28.0 cm | 40.5 cm | 40.0 cm | 58.0 cm |
Package 1 Weight | 4.0 kg | 5.566 kg | 5.92 kg | 9.48 kg |
Unit Type of Package 2 | S06 | S06 | S06 | S06 |
Number of Units in Package 2 | 4 | 6 | 6 | 3 |
Package 2 Height | 73.5 cm | 75.0 cm | 73.0 cm | 73.0 cm |
Package 2 Width | 80.0 cm | 80.0 cm | 80.0 cm | 80.0 cm |
Package 2 Length | 60.0 cm | 60.0 cm | 60.0 cm | 60.0 cm |
Package 2 Weight | 21.73 kg | 41.396 kg | 43.52 kg | 36.44 kg |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main | ||||
Part Number | ATV610D18N4 | ATV610D22N4 | ATV610D30N4 | ATV610D37N4 |
Range of product | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor |
Device short name | ATV610 | ATV610 | ATV610 | ATV610 |
Variant | Standard version | Standard version | Standard version | Standard version |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 | IP20 | IP20 | IP20 |
Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection |
supply frequency | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % |
network number of phases | 3 phases | 3 phases | 3 phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % |
motor power kW | 18.5 kW for normal duty | 22 kW for normal duty | 30 kW for normal duty | 37 kW for normal duty |
15 kW for heavy duty | 18.5 kW for heavy duty | 22 kW for heavy duty | 30 kW for heavy duty | |
motor power hp | 25 hp for normal duty | 30 hp for normal duty | 40 hp for normal duty | 50 hp for normal duty |
20 hp for heavy duty | 25 hp for heavy duty | 30 hp for heavy duty | 40 hp for heavy duty | |
line current | 37.2 A at 380 V (normal duty) | 41.9 A at 380 V (normal duty) | 62.5 A at 380 V (normal duty) | 76.6 A at 380 V (normal duty) |
33.5 A at 460 V (normal duty) | 36.2 A at 460 V (normal duty) | 55.8 A at 460 V (normal duty) | 68.3 A at 460 V (normal duty) | |
31.6 A at 380 V (heavy duty) | 36 A at 380 V (heavy duty) | 49.7 A at 380 V (heavy duty) | 65.8 A at 380 V (heavy duty) | |
28.3 A at 460 V (heavy duty) | 31.6 A at 460 V (heavy duty) | 42.5 A at 460 V (heavy duty) | 56.8 A at 460 V (heavy duty) | |
Prospective line Isc | 22 kA | 22 kA | 22 kA | 22 kA |
apparent power | 26.7 kVA at 460 V (normal duty) | 28.8 kVA at 460 V (normal duty) | 44.5 kVA at 460 V (normal duty) | 54.4 kVA at 460 V (normal duty) |
22.6 kVA at 460 V (heavy duty) | 25.2 kVA at 460 V (heavy duty) | 33.8 kVA at 460 V (heavy duty) | 45.2 kVA at 460 V (heavy duty) | |
continuous output current | 39.2 A at 4 kHz for normal duty | 46.3 A at 4 kHz for normal duty | 61.5 A at 4 kHz for normal duty | 74.5 A at 4 kHz for normal duty |
31.7 A at 4 kHz for heavy duty | 39.2 A at 4 kHz for heavy duty | 46.3 A at 4 kHz for heavy duty | 59.6 A at 4 kHz for heavy duty | |
maximum transient current | 43.1 A during 60 s (normal duty) | 50.9 A during 60 s (normal duty) | 67.7 A during 60 s (normal duty) | 82 A during 60 s (normal duty) |
47.6 A during 60 s (heavy duty) | 58.8 A during 60 s (heavy duty) | 69.5 A during 60 s (heavy duty) | 89.4 A during 60 s (heavy duty) | |
Asynchronous motor control profile | Variable torque standard | Constant torque standard | Variable torque standard | Constant torque standard |
Optimized torque mode | Variable torque standard | Constant torque standard | Optimized torque mode | |
Constant torque standard | Optimized torque mode | Optimized torque mode | Variable torque standard | |
Output frequency | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz |
Nominal switching frequency | 4 kHz | 4 kHz | 4 kHz | 4 kHz |
switching frequency | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable | 2…12 kHz adjustable |
number of preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds |
Communication port protocol | Modbus serial | Modbus serial | Modbus serial | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | |
Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 33.000 cm | 33 cm | 34.0 cm | 51.0 cm |
Package 1 Width | 25.000 cm | 25 cm | 51.0 cm | 38.0 cm |
Package 1 Length | 68.000 cm | 68 cm | 72.0 cm | 76.0 cm |
Package 1 Weight | 15.000 kg | 13.9 kg | 36.3 kg | 29.5 kg |
Unit Type of Package 2 | P06 | S06 | ||
Number of Units in Package 2 | 4 | 4 | ||
Package 2 Height | 77.000 cm | 149 cm | ||
Package 2 Width | 80.000 cm | 80 cm | ||
Package 2 Length | 60.000 cm | 60 cm | ||
Package 2 Weight | 80.000 kg | 74.5 kg | ||
Unit Type of Package 3 | P06 | |||
Number of Units in Package 3 | 4 | |||
Package 3 Height | 149 cm | |||
Package 3 Width | 80 cm | |||
Package 3 Length | 60 cm | |||
Package 3 Weight | 74.5 kg |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main | ||||
Part Number | ATV610D45N4 | ATV610D55N4 | ATV610D75N4 | ATV610D90N4 |
Range of product | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor |
Device short name | ATV610 | ATV610 | ATV610 | ATV610 |
Variant | Standard version | Standard version | Standard version | Standard version |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 | IP20 | IP20 | IP20 |
Type of cooling | Forced convection | Forced convection | Forced convection | Forced convection |
supply frequency | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % |
network number of phases | 3 phases | 3 phases | 3 phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % |
motor power kW | 45 kW for normal duty | 55 kW for normal duty | 75 kW for normal duty | 90 kW for normal duty |
37 kW for heavy duty | 45 kW for heavy duty | 55 kW for heavy duty | 75 kW for heavy duty | |
motor power hp | 60 hp for normal duty | 75 hp for normal duty | 100 hp for normal duty | 125 hp for normal duty |
50 hp for heavy duty | 60 hp for heavy duty | 75 hp for heavy duty | 100 hp for heavy duty | |
line current | 92.9 A at 380 V (normal duty) | 111.5 A at 380 V (normal duty) | 147.9 A at 380 V (normal duty) | 177.8 A at 380 V (normal duty) |
82.7 A at 460 V (normal duty) | 99.7 A at 460 V (normal duty) | 130.2 A at 460 V (normal duty) | 159.9 A at 460 V (normal duty) | |
80.5 A at 380 V (heavy duty) | 95.9 A at 380 V (heavy duty) | 115.8 A at 380 V (heavy duty) | 155.8 A at 380 V (heavy duty) | |
69.6 A at 460 V (heavy duty) | 84.0 A at 460 V (heavy duty) | 101.7 A at 460 V (heavy duty) | 138.1 A at 460 V (heavy duty) | |
Prospective line Isc | 22 kA | 22 kA | 22 kA | 50 kA |
apparent power | 65.9 kVA at 460 V (normal duty) | 79.5 kVA at 460 V (normal duty) | 103.7 kVA at 460 V (normal duty) | 127.4 kVA at 460 V (normal duty) |
55.4 kVA at 460 V (heavy duty) | 66.9 kVA at 460 V (heavy duty) | 81.0 kVA at 460 V (heavy duty) | 110.0 kVA at 460 V (heavy duty) | |
continuous output current | 88 A at 4 kHz for normal duty | 88 A at 2.5 kHz for heavy duty | 145 A at 2.5 kHz for normal duty | 173 A at 2.5 kHz for normal duty |
75 A at 4 kHz for heavy duty | 120 A at 2.5 kHz for normal duty | 106 A at 2.5 kHz for heavy duty | 145 A at 2.5 kHz for heavy duty | |
maximum transient current | 97 A during 60 s (normal duty) | 132 A during 60 s (heavy duty) | 160 A during 60 s (normal duty) | 190 A during 60 s (normal duty) |
112 A during 60 s (heavy duty) | 132 A during 60 s (normal duty) | 159 A during 60 s (heavy duty) | 218 A during 60 s (heavy duty) | |
Asynchronous motor control profile | Optimized torque mode | Optimized torque mode | Constant torque standard | Optimized torque mode |
Constant torque standard | Constant torque standard | Optimized torque mode | Variable torque standard | |
Variable torque standard | Variable torque standard | Variable torque standard | Constant torque standard | |
Output frequency | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz |
Nominal switching frequency | 4 kHz | 2.5 kHz | 2.5 kHz | 2.5 kHz |
switching frequency | 2…12 kHz adjustable | 1…8 kHz adjustable | 1…8 kHz adjustable | 1…8 kHz adjustable |
number of preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds |
Communication port protocol | Modbus serial | Modbus serial | Modbus serial | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | |
Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | |
Packing Units | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 34.0 cm | 47.0 cm | 46.5 cm | 46.5 cm |
Package 1 Width | 52.0 cm | 59.0 cm | 58.0 cm | 59.5 cm |
Package 1 Length | 73.0 cm | 87.0 cm | 93.5 cm | 94.0 cm |
Package 1 Weight | 30.2 kg | 70.5 kg | 70.5 kg | 67.0 kg |
[/fusion_table]
[fusion_table fusion_table_type=”1″ fusion_table_rows=”” fusion_table_columns=”” margin_top=”1 ps” margin_right=”1 ps” margin_bottom=”1 ps” margin_left=”1 ps” hide_on_mobile=”small-visibility,medium-visibility,large-visibility” class=”” id=”” animation_type=”” animation_direction=”left” animation_color=”” hue=”” saturation=”” lightness=”” alpha=”” animation_speed=”0.3″ animation_delay=”0″ animation_offset=””]
Main | |||
Part Number | ATV610C11N4 | ATV610C13N4 | ATV610C16N4 |
Range of product | Easy Altivar 610 | Easy Altivar 610 | Easy Altivar 610 |
Product or component type | Variable speed drive | Variable speed drive | Variable speed drive |
Product specific application | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor | Fan, pump, compressor, conveyor |
Device short name | ATV610 | ATV610 | ATV610 |
Variant | Standard version | Standard version | Standard version |
Product destination | Asynchronous motors | Asynchronous motors | Asynchronous motors |
Mounting mode | Cabinet mount | Cabinet mount | Cabinet mount |
EMC filter | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m | Integrated conforming to EN/IEC 61800-3 category C3 with 50 m |
IP degree of protection | IP20 | IP20 | IP20 |
Type of cooling | Forced convection | Forced convection | Forced convection |
supply frequency | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % | 50…60 Hz +/-5 % |
network number of phases | 3 phases | 3 phases | 3 phases |
[Us] rated supply voltage | 380…460 V – 15…10 % | 380…460 V – 15…10 % | 380…460 V – 15…10 % |
motor power kW | 110 kW for normal duty | 132 kW for normal duty | 160 kW for normal duty |
90 kW for heavy duty | 110 kW for heavy duty | 132 kW for heavy duty | |
motor power hp | 150 hp for normal duty | 200 hp for normal duty | 250 hp for normal duty |
125 hp for heavy duty | 150 hp for heavy duty | 200 hp for heavy duty | |
line current | 201 A at 380 V (normal duty) | 237 A at 380 V (normal duty) | 284 A at 380 V (normal duty) |
175.7 A at 460 V (normal duty) | 203.8 A at 460 V (normal duty) | 249.5 A at 460 V (normal duty) | |
170 A at 380 V (heavy duty) | 201 A at 380 V (heavy duty) | 237 A at 380 V (heavy duty) | |
149.1 A at 460 V (heavy duty) | 174.2 A at 460 V (heavy duty) | 205.9 A at 460 V (heavy duty) | |
Prospective line Isc | 50 kA | 50 kA | 50 kA |
apparent power | 140.0 kVA at 460 V (normal duty) | 162.4 kVA at 460 V (normal duty) | 198.8 kVA at 460 V (normal duty) |
118.8 kVA at 460 V (heavy duty) | 138.7 kVA at 460 V (heavy duty) | 164.0 kVA at 460 V (heavy duty) | |
continuous output current | 211 A at 2.5 kHz for normal duty | 250 A at 2.5 kHz for normal duty | 302 A at 2.5 kHz for normal duty |
173 A at 2.5 kHz for heavy duty | 211 A at 2.5 kHz for heavy duty | 250 A at 2.5 kHz for heavy duty | |
maximum transient current | 232 A during 60 s (normal duty) | 275 A during 60 s (normal duty) | 332 A during 60 s (normal duty) |
260 A during 60 s (heavy duty) | 317 A during 60 s (heavy duty) | 375 A during 60 s (heavy duty) | |
Asynchronous motor control profile | Variable torque standard | Variable torque standard | Constant torque standard |
Optimized torque mode | Optimized torque mode | Optimized torque mode | |
Constant torque standard | Constant torque standard | Variable torque standard | |
Output frequency | 0.0001…0.5 kHz | 0.0001…0.5 kHz | 0.0001…0.5 kHz |
Nominal switching frequency | 2.5 kHz | 2.5 kHz | 2.5 kHz |
switching frequency | 1…8 kHz adjustable | 1…8 kHz adjustable | 1…8 kHz adjustable |
number of preset speeds | 16 preset speeds | 16 preset speeds | 16 preset speeds |
Communication port protocol | Modbus serial | Modbus serial | Modbus serial |
option card | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 | Slot A: communication card, Profibus DP V1 |
Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | Slot A: digital or analog I/O extension card | |
Slot A: relay output card | Slot A: relay output card | Slot A: relay output card | |
Packing Units | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 47.0 cm | 45.5 cm | 48.0 cm |
Package 1 Width | 67.0 cm | 65.5 cm | 65.0 cm |
Package 1 Length | 103.0 cm | 103.0 cm | 103.0 cm |
Package 1 Weight | 96.344 kg | 99.0 kg | 97.461 kg |
[/fusion_table]
Weight | N/A |
---|---|
Dimensions | N/A |