| Main | 
| Part Number | TM200CE24T | TM200CE40T | 
| Range of product | Easy Modicon M200 | Easy Modicon M200 | 
| Product or component type | Logic controller | Logic controller | 
| [Us] rated supply voltage | 24 V DC | 24 V DC | 
| Discrete I/O number | 24 | 40 | 
| discrete input number | I2…I5: 4 fast input | I2…I5: 4 fast input | 
| I0, I1, I6, I7: 4 high speed input | I0, I1, I6, I7: 4 high speed input | 
| I8…I13: 6 regular input | I8…I23: 16 regular input | 
| discrete output number | Q0…Q1: 2 fast output (PLS/PWM/PTO mode) | Q0…Q1: 2 fast output (PLS/PWM/PTO mode) | 
| Q2…Q9: 8 transistor output | Q2…Q15: 14 transistor output | 
| Discrete input voltage | 24 V | 24 V | 
| Discrete input voltage type | DC | DC | 
| discrete input current | 7 mA for input | 7 mA for input | 
| discrete input logic | Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2 | Sink or source (positive/negative) type 1 conforming to EN/IEC 61131-2 | 
| discrete output voltage | 24 V DC | 24 V DC | 
| discrete output current | 0.5 A | 0.5 A | 
| Discrete output type | Transistor | Transistor | 
| Discrete output logic | Positive logic (source) | Positive logic (source) | 
| power consumption in W | 16 W at 24 V DC (with max I/O) | 18 W at 24 V DC (with max I/O) | 
| Complementary | 
| maximum number of I/O expansion module | 4 with 64 discrete output(s) for relay output | 4 with 64 discrete output(s) for relay output | 
| 4 with 138 discrete output(s) for transistor output | 4 with 144 discrete output(s) for transistor output | 
| Supply voltage limits | 20.4…28.8 V | 20.4…28.8 V | 
| Inrush current | 35 A | 35 A | 
| voltage state 1 guaranteed | >= 15 V for input | >= 15 V for input | 
| voltage state 0 guaranteed | <= 5 V for input | <= 5 V for input | 
| input impedance | 3.3 kOhm for discrete input | 3.3 kOhm for discrete input | 
| response time | 1 ms turn-on, Q0…Q9 terminal(s) for output | 1 ms turn-on, Q0…Q15 terminal(s) for output | 
| 1 ms turn-off, Q0…Q9 terminal(s) for output | 1 ms turn-off, Q0…Q15 terminal(s) for output | 
| 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input | 5 µs turn-off, I0, I1, I6, I7 terminal(s) for high speed input | 
| 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input | 5 µs turn-on, I0, I1, I6, I7 terminal(s) for high speed input | 
| 100 µs turn-off, I2…I5 terminal(s) for fast input | 100 µs turn-off, I2…I5 terminal(s) for fast input | 
| 35 µs turn-on, I2…I5 terminal(s) for fast input | 35 µs turn-on, I2…I5 terminal(s) for fast input | 
| 100 µs turn-off, I8…I13 terminal(s) for regular input | 100 µs turn-off, I8…I13 terminal(s) for regular input | 
| 35 µs turn-on, I8…I13 terminal(s) for regular input | 35 µs turn-on, I8…I13 terminal(s) for regular input | 
|  | 125 µs turn-off, I14…I23 terminal(s) for regular input | 
|  | 55 µs turn-on, I14…I23 terminal(s) for regular input | 
| configurable filtering time | 0 ms for input | 0 ms for input | 
| 3 ms for input | 3 ms for input | 
| 12 ms for input | 12 ms for input | 
| maximum current per output common | 2 A at COM 0 | 0.083333333 | 
| 3 A at COM 1 | 0.166666667 | 
| output frequency | 100 kHz for fast output (PWM/PLS mode) at Q0…Q1 | 100 kHz for fast output (PWM/PLS mode) at Q0…Q1 | 
| maximum leakage current | 0.1 mA for transistor output | 0.1 mA for transistor output | 
| maximum voltage drop | <1 V | <1 V | 
| maximum tungsten load | <12 W for output and fast output | <12 W for output and fast output | 
| protection type | Overload and short-circuit protection at 2 A | Overload and short-circuit protection at 2 A | 
| reset time | 1 s automatic reset | 1 s automatic reset | 
| memory capacity | 512 byte internal flash for backup of programs | 512 byte internal flash for backup of programs | 
| data storage equipment | 32 GB micro SD card (optional) | 32 GB micro SD card (optional) | 
| battery type | BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) | BR2032 Li-CFx (Lithium-Carbon Monofluoride), battery life: 5 year(s) | 
| backup time | 3 years at 25 °C (by interruption of power supply) | 3 years at 25 °C (by interruption of power supply) | 
| execution time for 1 KInstruction | 0.3 ms for event and periodic task | 0.3 ms for event and periodic task | 
| execution time per instruction | 0.2 µs Boolean | 0.2 µs Boolean | 
| exct time for event task | 60 µs response time | 60 µs response time | 
| clock drift | <= 90 s/month at 25 °C | <= 90 s/month at 25 °C | 
| regulation loop | Adjustable PID regulator up to 14 simultaneous loops | Adjustable PID regulator up to 14 simultaneous loops | 
| positioning functions | PWM/PLS 2 channel(s) at 100 kHz | PWM/PLS 2 channel(s) at 100 kHz | 
| control signal type | Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) | Quadrature (x1, x2, x4) at 100 kHz for fast input (HSC mode) | 
| Pulse/direction at 100 kHz for fast input (HSC mode) | Pulse/direction at 100 kHz for fast input (HSC mode) | 
| Single phase at 100 kHz for fast input (HSC mode) | Single phase at 100 kHz for fast input (HSC mode) | 
| CW/CCW at 100 kHz for fast input (HSC mode) | CW/CCW at 100 kHz for fast input (HSC mode) | 
| counting input number | 4 fast input (HSC mode) at 100 kHz 32 bits | 4 fast input (HSC mode) at 100 kHz 32 bits | 
| integrated connection type | USB port with mini B USB 2.0 connector | USB port with mini B USB 2.0 connector | 
| Non isolated serial link serial 1 with terminal block connector and RS485 interface | Non isolated serial link serial 1 with terminal block connector and RS485 interface | 
| Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface | Non isolated serial link serial 2 with terminal block connector and RS232/RS485 interface | 
| Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface | Ethernet Modbus TCP/IP Ethernet with RJ45 connector and 1 Ethernet port 10/100BASE-T interface | 
| Isolated serial link serial 2 with terminal block connector and RS485 interface | Isolated serial link serial 2 with terminal block connector and RS485 interface | 
| transmission rate | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 | 
| 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 | 1.2…115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 | 
| 12 Mbit/s for USB | 12 Mbit/s for USB | 
| 10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP | 10/100 Mbit/s for bus length of 100 m for Ethernet Modbus TCP/IP | 
| communication port protocol | USB port: USB – SoMachine-Network | USB port: USB – SoMachine-Network | 
| Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network | Non isolated serial link: Modbus master/slave – RTU/ASCII or SoMachine-Network | 
| Ethernet Modbus TCP/IP: Modbus TCP/IP client/server | Ethernet Modbus TCP/IP: Modbus TCP/IP client/server | 
| local signalling | 1 LED (green) for PWR | 1 LED (green) for PWR | 
| 1 LED (green) for RUN | 1 LED (green) for RUN | 
| 1 LED (red) for module error (ERR) | 1 LED (red) for module error (ERR) | 
| 1 LED (green) for SD card access (SD) | 1 LED (green) for SD card access (SD) | 
| 1 LED (red) for BAT | 1 LED (red) for BAT | 
| 1 LED (green) for SL1 | 1 LED (green) for SL1 | 
| 1 LED per channel (green) for I/O state | 1 LED per channel (green) for I/O state | 
| 2 LEDs (green) for communication (LK/ACT 10/100) | 2 LEDs (green) for communication (LK/ACT 10/100) | 
| electrical connection | Mini B USB 2.0 connectorfor a programming terminal | Mini B USB 2.0 connectorfor a programming terminal | 
| RJ45 connectorfor connecting Ethernet network | RJ45 connectorfor connecting Ethernet network | 
| removable screw terminal blockfor inputs | removable screw terminal blockfor inputs | 
| removable screw terminal blockfor outputs | removable screw terminal blockfor outputs | 
| removable screw terminal block, 3 terminal(s) for connecting the 24 V DC power supply | removable screw terminal block, 3 terminal(s) for connecting the 24 V DC power supply | 
| removable screw terminal block, 4 terminal(s) for connecting the serial link1 | removable screw terminal block, 4 terminal(s) for connecting the serial link1 | 
| maximum cable distance between devices | Unshielded cable: <50 m for input | Unshielded cable: <50 m for input | 
| Shielded cable: <10 m for fast input | Shielded cable: <10 m for fast input | 
| Shielded cable: <10 m for high speed input | Shielded cable: <10 m for high speed input | 
| Unshielded cable: <150 m for output | Unshielded cable: <150 m for output | 
| insulation | Non-insulated between inputs | Non-insulated between inputs | 
| Between input and internal logic at 500 V AC | Between input and internal logic at 500 V AC | 
| Between fast input and internal logic at 500 V AC | Between fast input and internal logic at 500 V AC | 
| Between input groups at 500 V AC | Between input groups at 500 V AC | 
| Between output and internal logic at 500 V AC | Between output and internal logic at 500 V AC | 
| Between output groups at 500 V AC | Between output groups at 500 V AC | 
| Between supply and internal logic at 500 V DC | Between supply and internal logic at 500 V DC | 
| Marking | CE | CE | 
| mounting support | Top hat type TH35-15 rail conforming to IEC 60715 | Top hat type TH35-15 rail conforming to IEC 60715 | 
| Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 | Top hat type TH35-7.5 plate or panel with fixing kit conforming to IEC 60715 | 
| Height | 90 mm | 90 mm | 
| Depth | 70 mm | 70 mm | 
| Width | 130 mm | 175 mm | 
| Product weight | 0.424 kg | 0.523 kg | 
| Environment | 
| IP degree of protection | IP20 with protective cover in place | IP20 with protective cover in place | 
| Standards | EN/IEC 61131-2 | EN/IEC 61131-2 | 
| EN/IEC 61010-2-201 | EN/IEC 61010-2-201 | 
| electromagnetic compatibility | Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 | Electrostatic discharge immunity test – test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 | 
| Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 | Electrostatic discharge immunity test – test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 | 
| Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3 | Susceptibility to electromagnetic fields – test level: 10 V/m (80 MHz…3 GHz) conforming to EN/IEC 61000-4-3 | 
| Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8 | Magnetic field at power frequency – test level: 30 A/m conforming to EN/IEC 61000-4-8 | 
| Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 | Electrical fast transient/burst immunity test – test level: 2 kV (power lines) conforming to EN/IEC 61000-4-4 | 
| Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 | Electrical fast transient/burst immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-4 | 
| Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 | Electrical fast transient/burst immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-4 | 
| Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 | Electrical fast transient/burst immunity test – test level: 1 kV (serial link) conforming to EN/IEC 61000-4-4 | 
| 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 2 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 2 kV (relay output) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 1 kV (I/O) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 1 kV (shielded cable) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 0.5 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 | 
| 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 | 1.2/50 µs shock waves immunity test – test level: 1 kV (power lines (AC)) conforming to EN/IEC 61000-4-5 | 
| Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 | Conducted RF disturbances – test level: 10 V (0.15…80 MHz) conforming to EN/IEC 61000-4-6 | 
| Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 | Conducted emission – test level: 79 dBμV/m QP/66 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 | 
| Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 | Conducted emission – test level: 73 dBμV/m QP/60 dBμV/m AV (power lines (AC)) conforming to EN/IEC 55011 | 
| Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 | Radiated emission – test level: 40 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 | 
| Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 | Radiated emission – test level: 47 dBμV/m QP class A (10 m) conforming to EN/IEC 55011 | 
| Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 | Electrical fast transient/burst immunity test – test level: 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 | 
| shock resistance | 15 gn for 11 ms | 15 gn for 11 ms | 
| 30 gn for 6 ms | 30 gn for 6 ms | 
| Immunity to microbreaks | 2 ms | 2 ms | 
| vibration resistance | 3.5 mm at 5…8.4 Hz on symmetrical rail | 3.5 mm at 5…8.4 Hz on symmetrical rail | 
| 1 gn at 8.4…150 Hz on symmetrical rail | 1 gn at 8.4…150 Hz on symmetrical rail | 
| 3.5 mm at 5…8.7 Hz on panel mounting | 3.5 mm at 5…8.7 Hz on panel mounting | 
| 2 gn at 8.7…150 Hz on panel mounting | 2 gn at 8.7…150 Hz on panel mounting | 
| relative humidity | 10…95 %, without condensation (in operation) | 10…95 %, without condensation (in operation) | 
| 10…95 %, without condensation (in storage) | 10…95 %, without condensation (in storage) | 
| ambient air temperature for operation | 0…55 °C (horizontal installation) | 0…55 °C (horizontal installation) | 
| Ambient air temperature for storage | -25…70 °C | -25…70 °C | 
| Pollution degree | <= 2 | <= 2 | 
| Operating altitude | 0…2000 m | 0…2000 m | 
| Storage altitude | 0…3000 m | 0…3000 m | 
| Packing Units | 
| Unit Type of Package 1 | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 
| Package 1 Height | 13.6 cm | 9.63 cm | 
| Package 1 Width | 9.0 cm | 13.735 cm | 
| Package 1 Length | 13.8 cm | 18.785 cm | 
| Package 1 Weight | 620.0 g | 766 g | 
| Unit Type of Package 2 | S03 | S03 | 
| Number of Units in Package 2 | 12 | 12 | 
| Package 2 Height | 30.0 cm | 30 cm | 
| Package 2 Width | 30.0 cm | 30 cm | 
| Package 2 Length | 40.0 cm | 40 cm | 
| Package 2 Weight | 8.105 kg | 9.713 kg | 
| Unit Type of Package 3 | P12 | P12 | 
| Number of Units in Package 3 | 288 | 288 | 
| Package 3 Height | 80.0 cm | 95 cm | 
| Package 3 Width | 120.0 cm | 80 cm | 
| Package 3 Length | 105.0 cm | 120 cm | 
| Package 3 Weight | 203.52 kg | 242.112 kg |