| Main |
| Part Number |
LC1E500M7N |
| Product Series |
Compact |
| product type |
Contactor |
| product short name |
LC1E |
| Application field of contactor |
Applied to non-inductive or micro-inductive loads, and |
| resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
| use category |
AC-3AC |
| -1 |
| number of poles |
3P |
| Rated working voltage [Ue] |
Power circuit: <= 690 V AC 50/60 Hz |
| Rated operating current [Ie] |
500 A 55 °C) at <= 440 V AC AC-3 for power circuits |
| 700 A 55 °C) at <= 440 V AC AC-1 for power circuits |
| [Uc] control circuit voltage |
230V AC 50/60Hz |
| Additional information |
| Motor power (kW) |
147 kW at 220/230 V AC 50/60 Hz (AC-3) |
| 250 kW at 380/400 V AC 50/60 Hz (AC-3) |
| 280 kW at 415/440 V AC 50/ 60 Hz (AC-3) |
| 295 kW at 415/440 V AC 50/60 Hz (AC-3) |
| 335 kW at 500 V AC 50/60 Hz (AC-3) |
| 355 kW at 660/ 690 V AC 50/60 Hz (AC-3) |
| Loop contact type |
3 NO |
| Conventional thermal current [Ith] |
700 A at <40 °C for power circuits |
| Rated making capacity [Irms] |
5000 A at 440 V AC for power circuits conforming to IEC 60947-4-1 |
| Rated breaking capacity |
4000 A at 440 V for power circuits conforming to IEC 60947 |
| Rated short-time withstand current [Icw] |
4200 A at <40 °C – 10 s for power circuits |
| Fuses for use with relays |
10 A gG at <= 690 V for type 1 suitable control circuits conforming to IEC 60947-5-1 |
| 800 A gG at <= 690 V for type 1 suitable power circuits |
| average impedance |
0.18 mΩ – Ith 700 A 50 Hz for power circuits |
| power consumption per pole |
45W AC-3 |
| 88W AC-1 |
| Rated insulation voltage [Ui] |
690 V conforming to IEC 60947-4-1 |
| Overvoltage category |
III |
| pollution level |
3 |
| Rated impulse withstand voltage [Uimp] |
8 kV coil not connected to power circuit conforming to IEC 60947 |
| Mechanical life |
4000000 times |
| Electrical life |
250000 times AC-1 |
| 600000 times AC-3 |
| Control loop characteristics |
AC at 50/60 Hz standard |
| Control voltage limit |
0.85…1.1 Uc 55 °C Run 50/60 Hz |
| 0.35…0.5 Uc 55 °C Release 50/60 Hz |
| (~50Hz pickup) power consumption (VA) |
1100 VA 50 Hz 0.9 20 °C) |
| 1100 VA 60 Hz 0.9 20 °C) |
| (~50Hz hold) power consumption (VA) |
18VA 50Hz 0.9 20°C) |
| 18VA 60Hz 0.9 20°C) |
| heat dissipation |
18 W for control circuit |
| 18 W |
| action time |
100…170 ms on opening |
| 40…75 ms off |
| operating frequency |
2400 cycles/h at <55 °C |
| Wiring capacity |
Control circuit: Bolt fastening1 1…4 mm² Cable option: Flexible cord without wire terminal |
| Control circuit: Bolt fastening2 1…4 mm² Cable option: Flexible cord without wire terminal |
| Control circuit: Bolt fastening 1 1…4 mm² cable option: flexible cable with cable terminals |
| control circuit: screw fastened2 1…2.5 mm² cable option: flexible cable with cable terminal |
| control circuit: screw cable option1 1…4 mm² cable option : Solid without wire terminals |
| Control circuit: Bolt tight2 1…4 mm² Cable selection: Solid without wire terminals |
| Power circuit: Cable with lug2 Lug outer diameter Ø: 240 mm |
| Power circuit: Terminal 2 Busbar cross-section: 40 x 5 mm |
| Tightening torque |
Control circuit: 1.2 Nm |
| Power circuit: 35 Nm |
| Auxiliary contact type |
Does not contain |
| Minimum switching voltage |
17 V for control circuits |
| Minimum switching current [Imin] |
5 mA for control loop |
| Insulation resistance |
> 10 MΩ for control loops |
| non-overlapping time |
1.5 ms power-on to ensure NC and NO contact |
| 1.5 ms power-off to ensure NC and NO contact |
| installation method |
Chassis mount |
| environment |
| standard |
IEC 60947-4-1 |
| GB 14048.4 |
| certified product |
CCC |
| IP protection class |
IP00 conforming to IEC 60529 |
| Protective measures |
TH (pollution degree 3) conforming to IEC 60068 |
| ambient air temperature |
-20…70 °C (allowed at Uc) |
| 5…55 °C operation |
| -60…80 °C storage |
| working altitude |
3000 m None |
| Fire resistance and abnormal high temperature resistance |
850 °C conforming to IEC 60695-2-1 |
| Shock and vibration resistance |
Shock resistance with contacts open (2 gn (5…300 Hz)) |
| shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance |
| with contacts closed (15 gn (11ms)) |
| Shock performance Contact opening (9 gn (11ms)) |
| high |
400 mm |
| width |
233 mm |
| depth |
232 mm |
| Product Weight |
11.35 kg |
| packaging unit |
| Unit Type of Package 1 |
PCE |
| Number of Units in Package 1 |
1 |
| Package 1 Height |
27.0cm |
| Package 1 Width |
28.5cm |
| Package 1 Length |
34.0cm |
| Package 1 Weight |
12560.0 g |
| Unit Type of Package 2 |
P06 |
| Number of Units in Package 2 |
8 |
| Package 2 Height |
69.0cm |
| Package 2 Width |
60.0cm |
| Package 2 Length |
80.0cm |
| Package 2 Weight |
110.48kg |
| contract warranty |
| Warranty |
18 months |