| Main | |||
| Part Number | LRE482N | LRE483N | LRE484N | 
| Product Series | Compact | Compact | Compact | 
| product name | EasyPact TVS | EasyPact TVS | EasyPact TVS | 
| product type | Type E 3 pole thermal overload relay | Type E 3 pole thermal overload relay | Type E 3 pole thermal overload relay | 
| product short name | LRE | LRE | LRE | 
| Relay application | Motor protection | Motor protection | Motor protection | 
| phase loss sensitivity | 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 | 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 | 1.3 Ir on two phases, 0 on the other phase conforming to IEC 60947-4-1 | 
| Additional information | |||
| The scope of products | LC1E120…630 | LC1E160…630 | LC1E200…630 | 
| Network Type | AC | AC | AC | 
| operating frequency | 50/60Hz | 50/60Hz | 50/60Hz | 
| installation method | Mounting on the bottom plate of the contactor, with special accessories | Mounting on the bottom plate of the contactor , with special accessories | Mounting on the bottom plate of the contactor , with special accessories | 
| Thermal release drag rating | Class 10A conforming to IEC 60947-4-1 | Class 10A conforming to IEC 60947-4-1 | Class 10A conforming to IEC 60947-4-1 | 
| Signal indication function | Relay Trip Indicator | Relay Trip Indicator | Relay Trip Indicator | 
| Relay setting range | 84…135A | 124…198A | 146…234A | 
| Trip threshold | 1.14 ± 0.06 In conforming to IEC 60947-4-1 | 1.14 ± 0.06 In conforming to IEC 60947-4-1 | 1.14 ± 0.06 In conforming to IEC 60947-4-1 | 
| Conventional thermal current [Ith] | 5 A for control circuits | 5 A for control circuits | 5 A for control circuits | 
| Rated working voltage [Ue] | <= 690V AC | <= 690V AC | <= 690V AC | 
| Fuses for use with relays | 5 A gG for control circuits 200 A gG for power circuits 160 A aM for power circuits | 5 A gG for control circuits 250 A gG for power circuits 200 A aM for power circuits | 5 A gG for control circuit 315 A gG for power circuit 250 A aM for power circuit | 
| Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 | 690 V conforming to IEC 60947-4-1 | 
| Rated impulse withstand voltage [Uimp] | 6kV | 6kV | 6kV | 
| control type | Stop: Red (push) button Reset: Green (push) button | Stop: Red (push) button Reset: Green (push) button | Stop: Red (push) button Reset: Green (push) button | 
| Temperature compensation | -20…60°C | -20…60°C | -20…60°C | 
| Phase spacing | 34.8 mm | 40 mm | 48 mm | 
| Wiring capacity | Terminal busbar cross-section: 3 x 18 mm | Terminal busbar cross-section: 3 x 20 mm | Terminal busbar cross-section: 3 x 25 mm | 
| Tightening torque | 27.5 Nm Via lug screw: M8 | 27.5 Nm Via lug screw: M8 | 35 Nm via lug screw: M10 | 
| high | 141 mm | 131 mm | 134 mm | 
| width | 180 mm | 180mm | 180 mm | 
| depth | 134 mm | 134 mm | 134 mm | 
| Product Weight | 1.67kg | 1.67kg | 1.67kg | 
| environment | |||
| Standards compliant | IEC 60947-4-1 GB 14048 | IEC 60947-4-1 GB 14048 | GB 14048 IEC 60947-4-1 | 
| certified product | CCC | CCC | CCC | 
| Protective measures | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 | 
| IP protection class | IP00 conforming to IEC 60529 | IP00 conforming to IEC 60529 | IP00 conforming to IEC 60529 | 
| ambient temperature | -20…60 °C without derating according to IEC 60947-4-1 -20…70 °C with derating | -20…60 °C without derating according to IEC 60947-4-1 -20…70 °C with derating | -20…60 °C without derating according to IEC 60947-4-1 -20…70 °C with derating | 
| storage environment temperature | -60…80°C | -60…80°C | -60…80°C | 
| Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60068-2-1 | 850 °C conforming to IEC 60068-2-1 | 850 °C conforming to IEC 60068-2-1 | 
| Shock and vibration resistance | Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7 Shock resistance: 6 gn conforming to IEC 60068-2-6 | Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7 Shock resistance: 6 gn conforming to IEC 60068-2-6 | Shock resistance: 6 gn (11ms) conforming to IEC 60068-2-7 Shock resistance: 6 gn conforming to IEC 60068-2-6 | 
| Insulation properties | 6 kV at 50 Hz conforming to IEC 60255-5 | 6 kV at 50 Hz conforming to IEC 60255-5 | 6 kV at 50 Hz conforming to IEC 60255-5 | 
| electromagnetic compatibility | Impulse withstand voltage: 6 kV conforming to IEC 60801-5 | Impulse withstand voltage: 6 kV conforming to IEC 60801-5 | Impulse withstand voltage: 6 kV conforming to IEC 60801-5 | 
| packaging unit | |||
| Unit Type of Package 1 | PCE | PCE | PCE | 
| Number of Units in Package 1 | 1 | 1 | 1 | 
| Package 1 Height | 16cm | 16cm | 16cm | 
| Package 1 Width | 17.7cm | 17.7cm | 17.7cm | 
| Package 1 Length | 27.5cm | 27.5cm | 27.5cm | 
| Package 1 Weight | 2813g | 2811.25g | 2846.25 g | 
| Unit Type of Package 2 | S03 | S03 | S03 | 
| Number of Units in Package 2 | 2 | 2 | 2 | 
| Package 2 Height | 30cm | 30cm | 30cm | 
| Package 2 Width | 30cm | 30cm | 30cm | 
| Package 2 Length | 40cm | 40cm | 40cm | 
| Package 2 Weight | 6.184 kg | 6.18kg | 6.25kg | 
| Unit Type of Package 3 | P06 | P06 | P06 | 
| Number of Units in Package 3 | 16 | 16 | 16 | 
| Package 3 Height | 75cm | 75cm | 75cm | 
| Package 3 Width | 60cm | 60cm | 60cm | 
| Package 3 Length | 80cm | 80cm | 80cm | 
| Package 3 Weight | 59.468 kg | 59.44 kg | 60kg | 
| contract warranty | |||
| Warranty | 18 months | 18 months | 18 months | 
| Weight | N/A | 
|---|---|
| Dimensions | N/A |