Specifications
Type | Wide-area fan type | ||||
Model No. | ER-TF04-EX | ER-TF06-EX | ER-TF08-EX | ||
CE marking directive compliance | EMC Directive, RoHS Directive | ||||
Charge removal time (±1,000 V → ±100 V) | 1 sec. approx. (Note 2) | ||||
Ion balance | ±10 V or less (Note 3) | ||||
Ozone generation | 0.02 ppm or less (Note 3) | ||||
Power supply voltage | Accessory AC adapter input: 100-240 V AC ± 10 % 50/60 Hz(Note 4) (Output: 24 V DC) |
||||
Power consumption | 80 VA or less (at 100 V: 70 VA or less) | ||||
Discharge method | Steady-state DC | ||||
Discharge output voltage | ±6,000 V approx. | ||||
Error output | NPN open-collector transistor • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) |
||||
Error output:Output operation | OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON | ||||
Error output:Short-circuit protection | Incorporated | ||||
Indicators | Bar | POWER | Green LED (Lights up when the power is ON) | ||
ERROR | Red LED (Lights up when discharge part error or fan error is detected) | ||||
CHECK | Orange LED (Lights up when discharge part check or fan check is detected) | ||||
Fan | Discharge part status |
Yellow LED (Lights up when discharge part error or discharge part check is detected) | |||
Fan status | RYellow LED (Lights up when fan error or fan check is detected) | ||||
Ambient temperature | 0 to + 50 ℃ + 32 to + 122 ℉ (No dew condensation), AC adapter: 0 to + 40 ℃ + 32 to + 104 ℉ |
||||
Ambient humidity | 35 to 65 % RH (No dew condensation allowed) | ||||
Material | Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: Cold rolled carbon steel (SPCC) | ||||
Net weight | 1.0 kg approx. | 1.2 kg approx. | 1.4 kg approx. | ||
Accessories | AC adapter (Note 3), F.G. connection cable: 1 pc., Spare replacement filters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
4)Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)