Specifications

Type Wide-area fan type
Model No. ER-TF04-EX ER-TF06-EX ER-TF08-EX
CE marking directive compliance EMC Directive, RoHS Directive
Charge removal time (±1,000 V → ±100 V) 1 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 3)
Ozone generation 0.02 ppm or less (Note 3)
Power supply voltage Accessory AC adapter input: 100-240 V AC ± 10 % 50/60 Hz(Note 4)
(Output: 24 V DC)
Power consumption 80 VA or less (at 100 V: 70 VA or less)
Discharge method Steady-state DC
Discharge output voltage ±6,000 V approx.
Error output NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
Error output:Output operation OFF if abnormal discharge, object inserted into discharge window or fan problem detected; normally ON
Error output:Short-circuit protection Incorporated
Indicators Bar POWER Green LED (Lights up when the power is ON)
ERROR Red LED (Lights up when discharge part error or fan error is detected)
CHECK Orange LED (Lights up when discharge part check or fan check is detected)
Fan Discharge part
status
Yellow LED (Lights up when discharge part error or discharge part check is detected)
Fan status RYellow LED (Lights up when fan error or fan check is detected)
Ambient temperature 0 to + 50 ℃ + 32 to + 122  (No dew condensation),
AC adapter: 0 to + 40 ℃ + 32 to + 104 
Ambient humidity 35 to 65 % RH (No dew condensation allowed)
Material Bar unit enclosure: ABS, Fan unit enclosure: ABS, Discharge needles: Tungsten, Mounting bracket: Cold rolled carbon steel (SPCC)
Net weight 1.0 kg approx. 1.2 kg approx. 1.4 kg approx.
Accessories AC adapter (Note 3), F.G. connection cable: 1 pc., Spare replacement filters: 5 pcs., Three-pronged outlet with ground pin: 1 pc., Blindfold seals: 2 sheets

Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Typical value at 200 mm 7.874 in from directly in front of air outlet at the unit center at maximum fan speed.
3) Typical value at 300 mm 11.811 in from directly in front of air outlet at the unit center at maximum fan speed.
4)Please prepare an AC cable separately as it is needed. The following cables are available as optionals: CN-ACCN-C2: AC cable (conforming to CCC), CN-ACKR-C2: AC cable (conforming to KTL)