Panasonic ER-X Series Ionizers were conceived with wide surface areas in mind. To achieve optimal charge removal of surfaces, various concepts were considered. Besides operation using variable air pressure (from airless to 5 bar air pressure), discharge frequency and ion balance can be set manually. Naturally these Ionizers can also be operated in automatic mode.
Other advantages include four different head sizes, from 160mm to 640mm in length, and the ability to connect up to two heads to one controller. Hence areas up to 1.2m wide can be handled. The heads feature an angle adjustment of 360° permitting the best possible charge neutralization.
Pulse Ac Method Area Ionizer ER-X Series Features :
- Manual Mode (Discharge Frequency And Ion Balance)
- Easy Maintenance
- Up To Two Heads Can Be Connected To One Controller
For the Part Number not in our attribute selection, please contact us directly: sales@inosaki.my
The Pulse Ac Method Area Ionizer ER-X Series Part Number :
ER-X016HC, ER-X016, ER-X064HC, ER-X032HC, ER-X008, ER-X048HC
ER-XC02, ER-X064, ER-X008HC, ER-X032, ER-X048, ER-X001
Super-compact slim head
By thoroughly redesigning the discharge needle, we have created a super-compact slim head that combines high-speed charge removal*1 with a maintenance-saving design*2. The ER-X series can be embedded in, or retrofitted onto, equipment that did not provide enough space for antistatic measures in the past.
*1: Pulse AC method with built-in air tubes (max. pressure 0.5 MPa)
*2: Discharge needle air barrier structure, discharge needle unit for simple need replacement
ORDER GUIDE
Heads [Head connection cable is not supplied with the head. Please order it separately.]
Type | Charge removal time (±1,000 V→±100 V) | Ion balance | Effective charge removal width | Model No. | ||
Bar type
|
Spot type | 0.3 sec. or less
(Note 1), 0.5 sec. or less (Note 2) |
±30 V or less
(Note 2, 3)
|
50 mm 1.969 in approx. | ER-X001
(Note 4) |
|
High and low temperature resistant | 1 sec. or less
(Note 2)
|
80 mm 3.150 in approx. | ER-X008
(Note 4) |
|||
ER-X008HC
(Note 5) |
||||||
High and low temperature resistant | 160 mm 6.299 in approx. | ER-X016 | ||||
ER-X016HC
(Note 5) |
||||||
High and low temperature resistant | 320 mm 12.598 in approx. | ER-X032 | ||||
ER-X032HC
(Note 5) |
||||||
High and low temperature resistant | 480 mm 18.898 in approx. | ER-X048 | ||||
ER-X048HC
(Note 5) |
||||||
High and low temperature resistant | 640mm 25.197 in approx. | ER-X064 | ||||
ER-X064HC
(Note 5) |
[/fusion_table]
Notes: 1) Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min. (0.3 MPa). 2) Typical value in condition of discharge distance 100 mm 3.937 in (ER-X001: 50 mm 1.969 in), center of the product, discharge frequency 50 Hz (ER-X□HC: 30 Hz) and no air supply.
- Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 °C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.
- The ER-X001 and ER-X008 must be combined with the new-type ER-XC02
For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.16.
- The ER-X□HC high / low temperature resistant type head can be used under temperatures from -60 to +200 °C -76 to +392 °F. Be sure to use this head in combination with the new-type controller, ER-XC02.
For the Identification of previous-type and new-type controllers and for the combination with the head, refer to p.16.
Controller [Please order power cable or AC adapter separately.]
Type | Model No. | Number of heads connected | Output |
Standard type | ER-XC02 | Max. 2 units | PhotoMOS relay |
[/fusion_table]
Head connection cables [Head connection cable is not supplied with the head. Please order it separately.]
Model No. | Description | |
ER-XCCJ2H | Length: 2 m 6.562 ft, Net weight: 120 g approx. | Cabtyre cable with both connector |
ER-XCCJ5H | Length: 5 m 16.404 ft, Net weight: 290 g approx. | |
ER-XCCJ10H (Note) | Length: 10 m 32.808 ft, Net weight: 560 g approx. |
[/fusion_table]
Note: Cannot be used with the high and low temperature resistant type head ER-X□HC.
Specifications
Item | Substance |
---|---|
Conformity Regulations and Certifications | EMC Directive, RoHS Directive, NRTL Certification |
Operating ambient temperature | 0~+50°C (non-condensing), storage: -10~+65°C |
Ambient humidity | 35~65%RH, Storage: 35~85%RH |
Vibration resistance | Endurance 10~150Hz Double amplitude 0.75mm (maximum acceleration 50m/s2) XYZ 2 hours in each direction |
Shockproof | Endurance 100m/s2 (approx. 10G) XYZ 3 times in each direction |
Case grounding method | floating |
material | Case: ABS |
mass | Net weight: Approx. 130g |
Number of heads connected | Up to 2 |
Power supply voltage | 24V DC±10% |
Current consumption | When one head is connected: 450 mA or less, when two heads are connected: 800 mA or less |
Indicator light | Displays the status of Head 1 and Head 2 |
Indicator Light: Discharge (DSC) | Green LED (illuminated when discharged) |
Indicator light: CHECK | Green LED (illuminated when discharged) |
Indicator light: ERROR | Red LED (illuminated when abnormal discharge is detected) |
Indicator light: Level meter | Green LED (5 levels. Lights up according to the amount of charge or ion generated, switches with a switch) |
Output [ALARM) ERROR Common | Photomos relay output • Maximum load current: 100 mA• Applied voltage: 30 V DC or less (output to output common) • Residual voltage: 1.5 V or less (at 100 mA load current) |
Output [ALARM) ERROR Common (COM)]: Output behavior | ALARM: ON when dirt or wear on the discharge needle is detected, OFF error when normal (ERROR): OFF when abnormal discharge is detected, ON when normal |
Output [ALARM ERROR] Common (COM): Short-circuit protection | Equipment (automatic return) |
Discharge control input (DSC OFF) | Discharge permission: open, discharge stop: 24V or 0V short circuit |
Withstand voltage | AC1,000V for 1 minute Single-case live parts |
Insulation resistance | 20MΩ or more at 250VDC mega Whole live parts and between cases |
accessory | Connectors for power supply and input/output connection: 1 set (housing 5557-10R, terminal 5556TL [made by Japan Molex]), ground wire (approx. 3.7m): 1 |
[/fusion_table]